I. Takai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
I. Takai has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
K Maeda
2 shared publicationsK. Maeda
Nagoya University Hospital, Department of In-Home Medicine, 65 Tsurumai, Showa-ku, Nagoya 466-8560, Japan Tel. +81-52-741-2133; Fax +81-52-744-1914
2 shared publicationsS Nakai
2 shared publicationsT Shinzato
Department of Internal Medicine, Branch Hospital, Nagoya University School of Medicine, Japan
2 shared publicationsT. Shinzato
Nagoya University Hospital, Department of In-Home Medicine, 65 Tsurumai, Showa-ku, Nagoya 466-8560, Japan Tel. +81-52-741-2133; Fax +81-52-744-1914
2 shared publicationsH Kobayakawa
1 shared publication
Latest Publications
- 1 June 2002
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 5 (2) , 123-131
Effect of creatinine generation rate on the relationship between hemodialysis prescription and health-related quality of life
- 1 June 2002
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 5 (2) , 123-131
Effect of creatinine generation rate on the relationship between hemodialysis prescription and health-related quality of life
- 1 April 1993
- Vol. 39 (2) , 137-40
A new wearable system for continuous monitoring of arteriovenous fistulae.
A wearable system to constantly monitor the bruit generated by an AV fistula at times other than during dialysis was developed, and provided early detection of rapidly developing thrombi that cause occlusion of the fistular vessels. The system consists of a downsized microphone that continuously monitors the bruit generated, a warning device worn like a wristwatch, and a wire running down from the microphone to the emergency warning device. The microphone converts the bruit into an electrical signal and outputs it to the warning device. The emergency warning is then sounded whenever the input signal from the tiny microphone is weaker than a preset level. The warning device was set off in 4 of 21 long-term dialysis patients with arteriovenous fistulas, and within several hours all 4 developed an occlusion. One of the 14 patients with a graft had the device go off while sleeping, but it was a false alarm due to positioning that resulted in compression of the fistula arm.
- 1 April 1993
- Vol. 39 (2) , 137-40
A new wearable system for continuous monitoring of arteriovenous fistulae.
A wearable system to constantly monitor the bruit generated by an AV fistula at times other than during dialysis was developed, and provided early detection of rapidly developing thrombi that cause occlusion of the fistular vessels. The system consists of a downsized microphone that continuously monitors the bruit generated, a warning device worn like a wristwatch, and a wire running down from the microphone to the emergency warning device. The microphone converts the bruit into an electrical signal and outputs it to the warning device. The emergency warning is then sounded whenever the input signal from the tiny microphone is weaker than a preset level. The warning device was set off in 4 of 21 long-term dialysis patients with arteriovenous fistulas, and within several hours all 4 developed an occlusion. One of the 14 patients with a graft had the device go off while sleeping, but it was a false alarm due to positioning that resulted in compression of the fistula arm.
- 1 March 1992
- Vol. 54, 1-10
Mechanism of dialysis-induced hypotension.
Dialysis-induced hypotension, the sharp decrease in blood pressure occurring during hemodialysis, remains one of the most difficult problems associated with hemodialysis even today. However, there is yet no established theory to explain the mechanism triggering dialysis-induced hypotension. This review attempts to offer a consistent and cohesive source of information on the hemodynamics during dialysis-induced hypotension, and then analyzes etiologic factors in such hypotension reported by various investigators. Finally, three hypotheses concerning the mechanism of dialysis-induced hypotension including our own are introduced.
- 1 March 1992
- Vol. 54, 1-10
Mechanism of dialysis-induced hypotension.
Dialysis-induced hypotension, the sharp decrease in blood pressure occurring during hemodialysis, remains one of the most difficult problems associated with hemodialysis even today. However, there is yet no established theory to explain the mechanism triggering dialysis-induced hypotension. This review attempts to offer a consistent and cohesive source of information on the hemodynamics during dialysis-induced hypotension, and then analyzes etiologic factors in such hypotension reported by various investigators. Finally, three hypotheses concerning the mechanism of dialysis-induced hypotension including our own are introduced.
- 1 July 1989
- Published by Wolters Kluwer Health in ASAIO Transactions
- Vol. 35 (3) , 245-246
Mechanism of Dialysis-Induced Hypotension
Using a hematocrit monitoring system and a Swan-Ganz catheter, the authors investigated the changes in blood volume and hemodynamic parameters before, during, and after dialysis-induced hypotension. When hypotension occurred, the cardiac output dropped sharply, and there were concomitant sudden decreases in the mean pulmonary arterial pressure and the mean right atrial pressure. These are attributed to a decrease in venous return. Since there was no recognizable change in blood volume when the blood pressure fell sharply, decrease in the venous return is considered to be caused by relocation of circulating blood, possibly associated with a sudden decrease in venous tone.
- 1 July 1989
- Published by Wolters Kluwer Health in ASAIO Transactions
- Vol. 35 (3) , 245-246
Mechanism of Dialysis-Induced Hypotension
Using a hematocrit monitoring system and a Swan-Ganz catheter, the authors investigated the changes in blood volume and hemodynamic parameters before, during, and after dialysis-induced hypotension. When hypotension occurred, the cardiac output dropped sharply, and there were concomitant sudden decreases in the mean pulmonary arterial pressure and the mean right atrial pressure. These are attributed to a decrease in venous return. Since there was no recognizable change in blood volume when the blood pressure fell sharply, decrease in the venous return is considered to be caused by relocation of circulating blood, possibly associated with a sudden decrease in venous tone.