Martin Ellenrieder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Martin Ellenrieder has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Rainer Bader
Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
6 shared publications Rainer Bader
Department of Orthopaedics, Rostock University Medical Center, Doberaner Strasse 142, 18057, Rostock, Germany
5 shared publicationsWolfram Mittelmeier
Department of Orthopaedics, Rostock University Medical Center, Doberaner Strasse 142, 18057, Rostock, Germany
5 shared publications- Wolfram Mittelmeier
Orthopedic Department, University Medicine Rostock, 18057 Rostock, Germany
5 shared publications Maximilian Haenle
Orthopädische Klinik und Poliklinik, Universität Rostock, Rostock, Germany
2 shared publicationsRobert Lenz
Orthopädische Klinik und Poliklinik, Universität Rostock, Rostock, Germany
2 shared publications
Latest Publications
- 30 September 2016
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (1) , 81-87
Patient-specific factors influencing the traction forces in hip arthroscopy
The application of traction in hip arthroscopy is associated with peri-operative complications. Within a therapeutic case series, patient-related factors correlating with high-traction forces during hip arthroscopy and occurring complications should be identified. In 30 male and 38 female patients (mean age: 44.5 years), intra-operative traction forces were monitored continuously using a specialised measurement device. A multivariate analysis was employed to identify patient-related factors influencing the traction force. Peri-operative complications (follow-up: 12 weeks) were evaluated by performing a single-case analysis. The mean initial force prior to penetration of the capsule (“initial force”) was 477 N (men: 517 N; women: 444 N), decreasing after capsulotomy by an average of 17 %. The male gender (p < 0.001), Kellgren and Lawrence radiographic stage (p = 0.037), low minimum joint-space width (p = 0.029) and high body height/weight (p = 0.003/0.037) correlated significantly with higher distraction forces. The patient age and type of anaesthesia (general versus spinal) were not relevant. Complications were observed in ten patients on the first post-operative day. In two of these patients a partial sensory deficit of the lateral cutaneous femoral nerve persisted after 12 weeks. All patients with complications required initial traction forces of >400 N. The study revealed several patient-specific risk factors correlating with high-traction forces during hip arthroscopy. With view to potential complications, these patient groups require special attention during surgical treatment as well as in future studies.
- 30 September 2016
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (1) , 81-87
Patient-specific factors influencing the traction forces in hip arthroscopy
The application of traction in hip arthroscopy is associated with peri-operative complications. Within a therapeutic case series, patient-related factors correlating with high-traction forces during hip arthroscopy and occurring complications should be identified. In 30 male and 38 female patients (mean age: 44.5 years), intra-operative traction forces were monitored continuously using a specialised measurement device. A multivariate analysis was employed to identify patient-related factors influencing the traction force. Peri-operative complications (follow-up: 12 weeks) were evaluated by performing a single-case analysis. The mean initial force prior to penetration of the capsule (“initial force”) was 477 N (men: 517 N; women: 444 N), decreasing after capsulotomy by an average of 17 %. The male gender (p < 0.001), Kellgren and Lawrence radiographic stage (p = 0.037), low minimum joint-space width (p = 0.029) and high body height/weight (p = 0.003/0.037) correlated significantly with higher distraction forces. The patient age and type of anaesthesia (general versus spinal) were not relevant. Complications were observed in ten patients on the first post-operative day. In two of these patients a partial sensory deficit of the lateral cutaneous femoral nerve persisted after 12 weeks. All patients with complications required initial traction forces of >400 N. The study revealed several patient-specific risk factors correlating with high-traction forces during hip arthroscopy. With view to potential complications, these patient groups require special attention during surgical treatment as well as in future studies.
- 1 March 2016
- Vol. 82 (1) , 60-7
Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.
Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred.
- 1 March 2016
- Vol. 82 (1) , 60-7
Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.
Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred.
- 1 November 2015
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 20 (6) , 1046-1052
Coexistent lumbar spine disorders have a crucial impact on the clinical outcome after total hip replacement
- 1 November 2015
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 20 (6) , 1046-1052
Coexistent lumbar spine disorders have a crucial impact on the clinical outcome after total hip replacement
- 1 February 2013
- Published by Springer Nature in Operative Orthopädie und Traumatologie
- Vol. 25 (1) , 85-94
Arthroskopisch gestützte Behandlung der aseptischen Hüftkopfnekrose
Preservation of the hip joint function by treatment of the avascular necrosis of the femoral head in adults or at least avoiding progression. Avascular necrosis of the femoral head in adults in Steinberg stages I-III. In patients with Steinberg stage IVa (subchondral collapse ≤ 15% of the articular surface, depression < 2 mm) hip joint salvage therapy in early stages of femoral head collapse. Manifest osteoarthritis of the hip joint. Joint infection. Relative contraindications: subchondral collapse > 15% of the articular surface or depression > 2 mm (Steinberg stage IVb and above). Persisting risk factors for a progression of avascular necrosis (e.g., alcohol abuse, chemotherapy, local irradiation, high-dose cortisone therapy) and obesity (BMI > 40). Arthroscopy of the hip joint in case of cartilage defects and/or potential collapse of the femoral head. Without collapse of the femoral head and absence of severe damage of the cartilage: core decompression using a guiding sleeve through a lateral approach (Steinberg II, III). Subsequently curettage of the necrotic area through a central drill hole and insertion of autogenic bone cylinders using an OATS harvester (Steinberg II b/c, III b/c). In Steinberg stage IVa, reconstruction of the outline of the femoral head is attempted by reduction of the impressed portion (under intraoperative fluoroscopy). Limited weight bearing (10 kg) of the operated leg for 6 weeks. In cases of large necrotic defects located directly beneath the subchondral bone (Steinberg IIIc) as well as subchondral collapse with flattening of the femoral head (Steinberg IVa) limited weight bearing (10 kg) for 12 weeks. Early results of femoral head preserving therapy in 53 patients (56 hips, consecutively treated between June 2004 and December 2009) after 33 ± 20 months: success rate (no arthroplasty, no reoperation, no radiological progress associated with clinical symptoms) 86% for patients treated with Steinberg stages I-III. Failure of the head preserving therapy with concern to the mentioned criteria depending on the initial Steinberg stage: 0 (0%) for stage I, 2 (10%) for stage II, 3 (25%) for stage III, and 4 (31%) for stage IVa.
- 1 February 2013
- Published by Springer Nature in Operative Orthopädie und Traumatologie
- Vol. 25 (1) , 85-94
Arthroskopisch gestützte Behandlung der aseptischen Hüftkopfnekrose
Preservation of the hip joint function by treatment of the avascular necrosis of the femoral head in adults or at least avoiding progression. Avascular necrosis of the femoral head in adults in Steinberg stages I-III. In patients with Steinberg stage IVa (subchondral collapse ≤ 15% of the articular surface, depression < 2 mm) hip joint salvage therapy in early stages of femoral head collapse. Manifest osteoarthritis of the hip joint. Joint infection. Relative contraindications: subchondral collapse > 15% of the articular surface or depression > 2 mm (Steinberg stage IVb and above). Persisting risk factors for a progression of avascular necrosis (e.g., alcohol abuse, chemotherapy, local irradiation, high-dose cortisone therapy) and obesity (BMI > 40). Arthroscopy of the hip joint in case of cartilage defects and/or potential collapse of the femoral head. Without collapse of the femoral head and absence of severe damage of the cartilage: core decompression using a guiding sleeve through a lateral approach (Steinberg II, III). Subsequently curettage of the necrotic area through a central drill hole and insertion of autogenic bone cylinders using an OATS harvester (Steinberg II b/c, III b/c). In Steinberg stage IVa, reconstruction of the outline of the femoral head is attempted by reduction of the impressed portion (under intraoperative fluoroscopy). Limited weight bearing (10 kg) of the operated leg for 6 weeks. In cases of large necrotic defects located directly beneath the subchondral bone (Steinberg IIIc) as well as subchondral collapse with flattening of the femoral head (Steinberg IVa) limited weight bearing (10 kg) for 12 weeks. Early results of femoral head preserving therapy in 53 patients (56 hips, consecutively treated between June 2004 and December 2009) after 33 ± 20 months: success rate (no arthroplasty, no reoperation, no radiological progress associated with clinical symptoms) 86% for patients treated with Steinberg stages I-III. Failure of the head preserving therapy with concern to the mentioned criteria depending on the initial Steinberg stage: 0 (0%) for stage I, 2 (10%) for stage II, 3 (25%) for stage III, and 4 (31%) for stage IVa.
- 1 January 2013
- Published by SAGE Publications in HIP International
- Vol. 23 (1) , 46-53
Treatment of Acetabular Defects during Revision Total Hip Arthroplasty - Preliminary Clinical and Radiological Outcome Using Bone Substitute Materials
Acetabular defects are a particular challenge during THR revision. Defects may be filled with autologous bone grafts, allografts or synthetic bone substitute materials. In this preliminary, retrospective study, 22 patients were treated with an oval shaped revision cup and a combination of synthetic bone substitute materials, namely hydroxyapatite and beta-tricalcium phosphate. The postoperative outcome was evaluated regarding the functional clinical outcome and quality of life using the Harris hip score, the WOMAC and the SF-36. Signs of loosening and changes of the implant position were evaluated from plain radiographs. Follow up examinations were performed after an average duration of 20.5 months (7-33 months). Postoperatively, we found a significant increase of the Harris hip score, and an increase in both the SF-36 and the WOMAC scores (without statistical significance). No radiographic signs of loosening were evident at the time of follow up. The use of synthetic bone substitute materials offers a possible alternative to the use of autologous and allogenic bone grafts in acetabular revision surgery. Further randomised controlled long-term studies are needed to verify the promising short-term results and to determine potential side effects, such as possible third body wear.
- 1 January 2013
- Published by SAGE Publications in HIP International
- Vol. 23 (1) , 46-53
Treatment of Acetabular Defects during Revision Total Hip Arthroplasty - Preliminary Clinical and Radiological Outcome Using Bone Substitute Materials
Acetabular defects are a particular challenge during THR revision. Defects may be filled with autologous bone grafts, allografts or synthetic bone substitute materials. In this preliminary, retrospective study, 22 patients were treated with an oval shaped revision cup and a combination of synthetic bone substitute materials, namely hydroxyapatite and beta-tricalcium phosphate. The postoperative outcome was evaluated regarding the functional clinical outcome and quality of life using the Harris hip score, the WOMAC and the SF-36. Signs of loosening and changes of the implant position were evaluated from plain radiographs. Follow up examinations were performed after an average duration of 20.5 months (7-33 months). Postoperatively, we found a significant increase of the Harris hip score, and an increase in both the SF-36 and the WOMAC scores (without statistical significance). No radiographic signs of loosening were evident at the time of follow up. The use of synthetic bone substitute materials offers a possible alternative to the use of autologous and allogenic bone grafts in acetabular revision surgery. Further randomised controlled long-term studies are needed to verify the promising short-term results and to determine potential side effects, such as possible third body wear.
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S53
BONY INTEGRATION OF TITANIUM IMPLANTS WITH A NOVEL BIOACTIVE CALCIUM TITANATE SURFACE TREATMENT IN A RABBIT MODEL
- 1 July 2012
- Published by Elsevier in Journal of Biomechanics
- Vol. 45, S53
BONY INTEGRATION OF TITANIUM IMPLANTS WITH A NOVEL BIOACTIVE CALCIUM TITANATE SURFACE TREATMENT IN A RABBIT MODEL
- 1 May 2012
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 17 (3) , 205-212
How stiffness and distal interlocking of revision hip stems influence the femoral cortical strain pattern
- 1 May 2012
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 17 (3) , 205-212
How stiffness and distal interlocking of revision hip stems influence the femoral cortical strain pattern
- 1 January 2012
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 57 (2) , 121-9
Influence of cementless hip stems on femoral cortical strain pattern depending on their extent of porous coating
The extent of porous coating of cementless total hip stems is held responsible for radiological periprosthetic changes, the rate of thigh pain, and even its long-term success. However, there is only sparse knowledge on how the biomechanical loading conditions of the femur are influenced by the extent of porous coating in the early phase after implantation of a cementless hip stem. Aiming to evaluate the effect of surface structuring on the strain pattern of the femur, we implanted three anatomic hip stems with different extents of porous coating (full, two-thirds proximal, and penguin type) in second-generation composite femora coated with a photoelastic layer. A cortical strain mapping was conducted before and after insertion of the implants under standardized loading conditions considering relevant muscle forces. The results of the statistical analysis of three different implantation sequences proved that composite femora are suitable for repeated measurements within the applied experimental setup. Cortical strain changes including stress-shielding effects medially (-60%) and laterally (-50%) were validated with a cadaver femur. The extent of porous coating had no significant influence on the surface strain pattern for an immediate postoperative situation.
- 1 January 2012
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 57 (2) , 121-9
Influence of cementless hip stems on femoral cortical strain pattern depending on their extent of porous coating
The extent of porous coating of cementless total hip stems is held responsible for radiological periprosthetic changes, the rate of thigh pain, and even its long-term success. However, there is only sparse knowledge on how the biomechanical loading conditions of the femur are influenced by the extent of porous coating in the early phase after implantation of a cementless hip stem. Aiming to evaluate the effect of surface structuring on the strain pattern of the femur, we implanted three anatomic hip stems with different extents of porous coating (full, two-thirds proximal, and penguin type) in second-generation composite femora coated with a photoelastic layer. A cortical strain mapping was conducted before and after insertion of the implants under standardized loading conditions considering relevant muscle forces. The results of the statistical analysis of three different implantation sequences proved that composite femora are suitable for repeated measurements within the applied experimental setup. Cortical strain changes including stress-shielding effects medially (-60%) and laterally (-50%) were validated with a cadaver femur. The extent of porous coating had no significant influence on the surface strain pattern for an immediate postoperative situation.
- 27 June 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (4) , 469-471
Spondylodiscitis of the lumbar spine in a non-immunocompromised host caused by Yersinia enterocolitica O:9
Here presented is an extremely rare case of a spinal osteomyelitis (L5–S1) with epidural empyema in a non-immunocompromised 62-year-old man caused by Yersinia enterocolitica O:9. The infection occurred acutely and required immediate surgical treatment. Y. enterocolitica was cultured from the empyema fluid, wound swabs of the intervertebral disc L5–S1 and stool cultures. Following the surgical decompression and antibiotic treatment, the patient recovered completely, without neurological deficits. A review of the literature revealed only sparse cases of spondylodiscitis due to other Y. enterocolitica serogroups. To our knowledge, we report here the first case of a spondylodiscitis of the lumbar spine caused by Y. enterocolitica serovar O:9 in a non-immunocompromised patient.
- 27 June 2009
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 130 (4) , 469-471
Spondylodiscitis of the lumbar spine in a non-immunocompromised host caused by Yersinia enterocolitica O:9
Here presented is an extremely rare case of a spinal osteomyelitis (L5–S1) with epidural empyema in a non-immunocompromised 62-year-old man caused by Yersinia enterocolitica O:9. The infection occurred acutely and required immediate surgical treatment. Y. enterocolitica was cultured from the empyema fluid, wound swabs of the intervertebral disc L5–S1 and stool cultures. Following the surgical decompression and antibiotic treatment, the patient recovered completely, without neurological deficits. A review of the literature revealed only sparse cases of spondylodiscitis due to other Y. enterocolitica serogroups. To our knowledge, we report here the first case of a spondylodiscitis of the lumbar spine caused by Y. enterocolitica serovar O:9 in a non-immunocompromised patient.