Thomas Frank
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thomas Frank has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
S. Hermann
6 shared publicationsA. Grün
CiS Forschungsinstitut für Mikrosensorik Konrad-Zuse-Straße 14 99099 Erfurt Deutschland
5 shared publicationsA. Cyriax
CiS Forschungsinstitut für Mikrosensorik Konrad-Zuse-Straße 14 99099 Erfurt Deutschland
3 shared publicationsM. Kermann
CiS Forschungsinstitut für Mikrosensorik Konrad-Zuse-Straße 14 99099 Erfurt Deutschland
3 shared publicationsD. Hanig
CiS Forschungsinstitut für Mikrosensorik Konrad-Zuse-Straße 14 99099 Erfurt Germany
2 shared publicationsH. Wünscher
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by AMA Service GmbH
- p. 279
P24 - Add-on kit for non-invasive pressure measurement on process pipes
This article presents a sensor system for non-invasive pressure measurement in process pipes. This is a back-fitting kit in the form of a sensitive sleeve with an integrated pressure sensor system. The direct coupling detects the exact changes in expansion of process pipes. When used as a monitoring system, statements can be made about material changes, wear mechanisms, maintenance, energy consumption under operating conditions or reactions to external influencing factors.
- 1 January 2025
- Published by AMA Service GmbH
- p. 279
Open AccessP24 - Add-on kit for non-invasive pressure measurement on process pipes
This article presents a sensor system for non-invasive pressure measurement in process pipes. This is a back-fitting kit in the form of a sensitive sleeve with an integrated pressure sensor system. The direct coupling detects the exact changes in expansion of process pipes. When used as a monitoring system, statements can be made about material changes, wear mechanisms, maintenance, energy consumption under operating conditions or reactions to external influencing factors.
- Open Access
- 1 January 2025
- Published by AMA Service GmbH
- p. 277-278
P23 - Signal evaluation of force sensors based on silicon strain gauges using artificial neural networks
- 1 January 2025
- Published by AMA Service GmbH
- p. 277-278
Open AccessP23 - Signal evaluation of force sensors based on silicon strain gauges using artificial neural networks
- Open Access
- 1 January 2025
- Published by AMA Service GmbH
- p. 273-274
P21 - Elastically stable tensile force sensors for belt tension monitoring
In drive technology, timing belts and transmission belts are used to transmit large forces at large distances. Optimal power transmission depends on the belt tension. Consistently perfect belt tension increases service life and reduces wear. This ensures consistent quality and technical safety in the respective application. This article describes a silicon strain sensor and the necessary connection technology to enable continuous determination of the belt tension.
- 1 January 2025
- Published by AMA Service GmbH
- p. 273-274
Open AccessP21 - Elastically stable tensile force sensors for belt tension monitoring
In drive technology, timing belts and transmission belts are used to transmit large forces at large distances. Optimal power transmission depends on the belt tension. Consistently perfect belt tension increases service life and reduces wear. This ensures consistent quality and technical safety in the respective application. This article describes a silicon strain sensor and the necessary connection technology to enable continuous determination of the belt tension.
- Open Access
- 1 January 2025
- Published by AMA Service GmbH
- p. 275-276
P22 - Optimized hardness testing: Precise force application and measurement at low forces
- 1 January 2025
- Published by AMA Service GmbH
- p. 275-276
Open AccessP22 - Optimized hardness testing: Precise force application and measurement at low forces
- Open Access
- 1 January 2024
- Published by AMA Service GmbH
- p. 460-454
P11 - Siliziumdehnungssensoren zur Werkzeuginnendruckmessung
- 1 January 2024
- Published by AMA Service GmbH
- p. 460-454
Open AccessP11 - Siliziumdehnungssensoren zur Werkzeuginnendruckmessung
- Open Access
- 1 January 2023
- Published by AMA Service GmbH
- p. 312-313
P17 - Setting up a pressure sensor with flush membrane and without oil filling
- 1 January 2023
- Published by AMA Service GmbH
- p. 312-313
Open AccessP17 - Setting up a pressure sensor with flush membrane and without oil filling
- Open Access
- 17 May 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 6 (1) , 53
Failure Analysis of Wire Bonding on Strain Gauge Contact Pads Using FIB, SEM, and Elemental Mapping
Stacks consisting of titanium, platinum, and gold layers constitute a popular metallization system for the bond pads of semiconductor chips. Wire bonding on such layer stacks at different temperatures has extensively been investigated in the past. However, reliable information on the bondability of this metallization system after a high-temperature sintering process is still missing. When performing wire bonding after pressure sintering (at, e.g., 875 °C), bonding failures may occur that must be identified and analyzed. In the present study, a focused ion beam (FIB), scanning electron microscopy (SEM), and elemental mapping are utilized to characterize the root cause of failure. As a probable root cause, the infusion of metallization layers is found which causes an agglomerate formation at the interface of approximately 2 μm height difference on strain gauge contact pads and possibly an inhomogeneous mixing of layers as a consequence of the high-temperature sintering process. Potential treatment to tackle this agglomeration with the removal of the above-mentioned height difference during the process of contact pad structuring and alternative electrical interconnect methodologies are hereby suggested in this paper.
- 17 May 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 6 (1) , 53
Open AccessFailure Analysis of Wire Bonding on Strain Gauge Contact Pads Using FIB, SEM, and Elemental Mapping
Stacks consisting of titanium, platinum, and gold layers constitute a popular metallization system for the bond pads of semiconductor chips. Wire bonding on such layer stacks at different temperatures has extensively been investigated in the past. However, reliable information on the bondability of this metallization system after a high-temperature sintering process is still missing. When performing wire bonding after pressure sintering (at, e.g., 875 °C), bonding failures may occur that must be identified and analyzed. In the present study, a focused ion beam (FIB), scanning electron microscopy (SEM), and elemental mapping are utilized to characterize the root cause of failure. As a probable root cause, the infusion of metallization layers is found which causes an agglomerate formation at the interface of approximately 2 μm height difference on strain gauge contact pads and possibly an inhomogeneous mixing of layers as a consequence of the high-temperature sintering process. Potential treatment to tackle this agglomeration with the removal of the above-mentioned height difference during the process of contact pad structuring and alternative electrical interconnect methodologies are hereby suggested in this paper.
- Open Access
Long Slender Piezo-Resistive Silicon Microprobes for Fast Measurements of Roughness and Mechanical Properties inside Micro-Holes with Diameters below 100 µm
During the past decade, piezo-resistive cantilever type silicon microprobes for high-speed roughness measurements inside high-aspect-ratio microstructures, like injection nozzles or critical gas nozzles have been developed. This article summarizes their metrological properties for fast roughness and shape measurements including noise, damping, tip form, tip wear, and probing forces and presents the first results on the measurement of mechanical surface parameters. Due to the small mass of the cantilever microprobes, roughness measurements at very high traverse speeds up to 15 mm/s are possible. At these high scanning speeds, considerable wear of the integrated silicon tips was observed in the past. In this paper, a new tip-testing artefact with rectangular grooves of different width was used to measure this wear and to measure the tip shape, which is needed for morphological filtering of the measured profiles and, thus, for accurate form measurements. To reduce tip wear, the integrated silicon tips were replaced by low-wear spherical diamond tips of a 2 µm radius. Currently, a compact microprobe device with an integrated feed-unit is being developed for high-speed roughness measurements on manufacturing machines. First measurements on sinusoidal artefacts were carried out successfully. Moreover, the first measurements of the elastic modulus of a polymer surface applying the contact resonance measurement principle are presented, which indicates the high potential of these microprobes for simultaneous high-speed roughness and mechanical parameter measurements.
Open AccessLong Slender Piezo-Resistive Silicon Microprobes for Fast Measurements of Roughness and Mechanical Properties inside Micro-Holes with Diameters below 100 µm
During the past decade, piezo-resistive cantilever type silicon microprobes for high-speed roughness measurements inside high-aspect-ratio microstructures, like injection nozzles or critical gas nozzles have been developed. This article summarizes their metrological properties for fast roughness and shape measurements including noise, damping, tip form, tip wear, and probing forces and presents the first results on the measurement of mechanical surface parameters. Due to the small mass of the cantilever microprobes, roughness measurements at very high traverse speeds up to 15 mm/s are possible. At these high scanning speeds, considerable wear of the integrated silicon tips was observed in the past. In this paper, a new tip-testing artefact with rectangular grooves of different width was used to measure this wear and to measure the tip shape, which is needed for morphological filtering of the measured profiles and, thus, for accurate form measurements. To reduce tip wear, the integrated silicon tips were replaced by low-wear spherical diamond tips of a 2 µm radius. Currently, a compact microprobe device with an integrated feed-unit is being developed for high-speed roughness measurements on manufacturing machines. First measurements on sinusoidal artefacts were carried out successfully. Moreover, the first measurements of the elastic modulus of a polymer surface applying the contact resonance measurement principle are presented, which indicates the high potential of these microprobes for simultaneous high-speed roughness and mechanical parameter measurements.
- 1 February 2014
- Published by Springer Nature in Microsystem Technologies
- Vol. 20 (4-5) , 927-931
Silicon cantilevers with piezo-resistive measuring bridge for tactile line measurement
- 1 February 2014
- Published by Springer Nature in Microsystem Technologies
- Vol. 20 (4-5) , 927-931
Silicon cantilevers with piezo-resistive measuring bridge for tactile line measurement
- Open Access
- 15 June 2012
- Published by Springer Nature in Microsystem Technologies
- Vol. 18 (7) , 1225-1231
Binary Zero-Power Sensors: an alternative solution for power-free energy-autonomous sensor systems
- 15 June 2012
- Published by Springer Nature in Microsystem Technologies
- Vol. 18 (7) , 1225-1231
Open AccessBinary Zero-Power Sensors: an alternative solution for power-free energy-autonomous sensor systems