BLBiao Lu

Biao Lu

*This is an algorithmically generated author record based on publicly available information.

Biao Lu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging

    by Xiaoyong Huang, Xin Pu, Ruiyu Dou, Xi Guo, Zixu Yan, Zhaoqi Zhang, Meng Li, Hong Jiang, Biao Lu

    To evaluate the accuracy and feasibility of right ventricular function parameters measurement using 320-slice volume cardiac CT. Retrospective analysis of 50 consecutive patients (23 men, 27 women) with suspected pulmonary diseases was performed in electrocardiogram (ECG)-gated cardiac CT and cardiac magnetic resonance (CMR). Parameters including right ventricular end-diastolic volume (RVEDV), right ventricular end- systolic volume (RVESV), right ventricular stroke volume (RVSV), right ventricular cardiac output (RVCO), and right ventricular ejection fraction (RVEF) were semi-automatically and separately calculated from both CT and CMR data. Significant difference between measurements was measured by paired t test and two-variable linear regression analysis with Pearson’s correlation coefficient. Bland–Altman analysis was performed in each pair of parameters. There was little variability between the measurements by the two observers (kappa = 0.895–0.980, P < 0.05). There was good correlation between all parameters obtained by CT and CMR (P < 0.001): RVEDV (108.5 ± 21.9 ml, 113.5 ± 24.8 ml, r = 0.944), RVESV (69.8 ± 33.4 ml, 73.2 ± 35.4 ml, r = 0.972), RVSV (39.0 ± 13.2 ml, 40.2 ± 13.3 ml, r = 0.977), RVCO (2.6 ± 0.7 l, 2.6 ± 0.7 l. r = 0.958), RVEF (38.8 ± 19.1 %, 39.1 ± 19.3 %, r = 0.990), and there was no significant difference between CT and CMR measurements in RVEF (n = 50, t = −0.677, P > 0.05). 320-slice volume cardiac CT is an accurate non-invasive technique to evaluate RV function.


  • Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results

    by Lei Xu, Lin Yang, Zhanming Fan, Wei Yu, Biao Lv, Zhaoqi Zhang

    Objective To evaluate the feasibility, diagnostic accuracy, and radiation dose of CT coronary angiography (CTCA) in patients with atrial fibrillation (AF) using 320-detector CT. Methods Thirty-seven patients with persistent AF and suspected coronary artery disease (CAD) were enrolled. All patients underwent both 320-detector CTCA and conventional coronary angiography (CCA). CT image quality and the presence of significant (≥50%) stenosis were evaluated by two radiologists blinded to the results of CCA. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated using CCA as the reference standard. Differences in detection of coronary artery stenosis between 320-detector CTCA and CCA were evaluated with McNemar’s test. Patient radiation dose was calculated by multiplying dose length product by conversion coefficient of 0.017. Results In total 474 evaluated coronary segments, 459 (96.8%) segments were diagnostically evaluable. On per-segment analysis, sensitivity, specificity, PPV and NPV were 90.0% (18 of 20), 99.3% (436 of 439), 85.7% (18 of 21) and 99.5% (436 of 438). No significant difference was found between 320-detector CTCA and CCA on the detection of significant stenosis (P = 1.000). Effective doses of 320-detector CTCA was 13.0 ± 4.7 mSv. Conclusion 320-detector CTCA is feasible and accurate in excluding CAD in patients with AF.


  • Low Injection Rate for 3D Moving-Table Bolus-Chase MR Angiography: Initial Experience with 3-T Imaging to Allay Venous Contamination in the Calf

    by Kai Lin, Zhao-Qi Zhang, Jun-Yan Sun, Zhan-Ming Fan, Biao Lu

    OBJECTIVE. The purpose of this study was to evaluate the potential for improving the image quality of 3D bolus-chase peripheral MR angiography by injecting contrast medium at a slow rate. SUBJECTS AND METHODS. Using similar imaging parameters in all cases, we performed bolus-chase MR angiography of the abdominal and lower limb arteries of 80 patients. The injection protocol for 40 patients had three parts: 20 mL of gadopentetate dimeglumine at 2 mL/s, 8 mL of gadopentetate dimeglumine at 1 mL/s, and 20 mL of saline solution at 1 mL/s. For the other 40 patients, the injection protocol was 20 mL of gadopentetate dimeglumine at 1.2 mL/s, 8 mL of gadopentetate dimeglumine at 0.7 mL/s, and 20 mL of saline solution at 0.7 mL/s. Using independent Student's t tests between groups, we compared signal-to-noise and contrast-to-noise ratios in the abdomen and pelvis, the thigh, and the calf. Arterial visibility and venous contamination on 3D images of the calf were graded and compared. RESULTS. The lower injection rate increased arterial visibility (p < 0.001), reduced venous contamination in the calf (p < 0.001), and increased the contrast-to-noise ratio in the calf (p < 0.001). At the upper levels, signal-to-noise and contrast-to-noise ratios did not differ between the two groups. CONCLUSION. At 3-T MRI, a lower injection rate may alleviate venous contamination and increase arterial visibility in the calf while signal-to-noise and contrast-to-noise ratios at higher levels are maintained.