Khaldon Lweesy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Khaldon Lweesy has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Hartmut Dickhaus
University of Heidelberg
2 shared publicationsLuay Fraiwan
Jordan University of Science and Technology
2 shared publications- Luay Fraiwan
Department of Biomedical Engineering, Jordan University of Science and Technology, Irbid, Jordan
2 shared publications Abduallah Dawodiah
Jordan University of Science and Technology
1 shared publicationAlaa Shatat
Jordan University of Science and Technology
1 shared publication- Amna Almarzooqi
Department of Electrical, Computer and Biomedical Engineering, Abu Dhabi University, Abu Dhabi 55991, United Arab Emirates
1 shared publication
Latest Publications
- Open Access
- 21 February 2026
- Published by Springer Nature
- p. 79-85
Feature Selection for Hand Gesture Recognition Using Six FSR Sensors Bracelet
Gesture recognition plays a critical role in applications ranging from gaming and remote manipulation to assistive technologies for individuals with disabilities. Force myography (FMG) has recently emerged as a promising approach for gesture recognition due to its strong classification capabilities. In this study, eleven American Sign Language (ASL) gestures were classified using FMG signals. To improve classification accuracy, three advanced swarm-based feature selection algorithms: the Binary Gray Wolf Optimizer (BGWO), Binary Grasshopper Optimization Algorithm (BGOA), and Binary Hybrid Gray Wolf Particle Swarm Optimizer (BGWOPSO), were evaluated as wrapper methods for an Extreme Learning Machine (ELM) classifier. Ten volunteers contributed data using a bracelet equipped with six force-sensitive resistor (FSR) sensors. Results show that the BGWOPSO-based feature selection approach significantly outperformed the other methods, increasing ELM classification accuracy from 55.82% to 91.36%.
- 21 February 2026
- Published by Springer Nature
- p. 79-85
Open AccessFeature Selection for Hand Gesture Recognition Using Six FSR Sensors Bracelet
Gesture recognition plays a critical role in applications ranging from gaming and remote manipulation to assistive technologies for individuals with disabilities. Force myography (FMG) has recently emerged as a promising approach for gesture recognition due to its strong classification capabilities. In this study, eleven American Sign Language (ASL) gestures were classified using FMG signals. To improve classification accuracy, three advanced swarm-based feature selection algorithms: the Binary Gray Wolf Optimizer (BGWO), Binary Grasshopper Optimization Algorithm (BGOA), and Binary Hybrid Gray Wolf Particle Swarm Optimizer (BGWOPSO), were evaluated as wrapper methods for an Extreme Learning Machine (ELM) classifier. Ten volunteers contributed data using a bracelet equipped with six force-sensitive resistor (FSR) sensors. Results show that the BGWOPSO-based feature selection approach significantly outperformed the other methods, increasing ELM classification accuracy from 55.82% to 91.36%.
- Open Access
Non-Contact Spirometry Using a Mobile Thermal Camera and AI Regression
Non-contact physiological measurements have been under investigation for many years, and among these measurements is non-contact spirometry, which could provide acute and chronic pulmonary disease monitoring and diagnosis. This work presents a feasibility study for non-contact spirometry measurements using a mobile thermal imaging system. Thermal images were acquired from 19 subjects for measuring the respiration rate and the volume of inhaled and exhaled air. A mobile application was built to measure the respiration rate and export the respiration signal to a personal computer. The mobile application acquired thermal video images at a rate of nine frames/second and the OpenCV library was used for localization of the area of interest (nose and mouth). Artificial intelligence regressors were used to predict the inhalation and exhalation air volume. Several regressors were tested and four of them showed excellent performance: random forest, adaptive boosting, gradient boosting, and decision trees. The latter showed the best regression results, with an R-square value of 0.9998 and a mean square error of 0.0023. The results of this study showed that non-contact spirometry based on a thermal imaging system is feasible and provides all the basic measurements that the conventional spirometers support.
Open AccessNon-Contact Spirometry Using a Mobile Thermal Camera and AI Regression
Non-contact physiological measurements have been under investigation for many years, and among these measurements is non-contact spirometry, which could provide acute and chronic pulmonary disease monitoring and diagnosis. This work presents a feasibility study for non-contact spirometry measurements using a mobile thermal imaging system. Thermal images were acquired from 19 subjects for measuring the respiration rate and the volume of inhaled and exhaled air. A mobile application was built to measure the respiration rate and export the respiration signal to a personal computer. The mobile application acquired thermal video images at a rate of nine frames/second and the OpenCV library was used for localization of the area of interest (nose and mouth). Artificial intelligence regressors were used to predict the inhalation and exhalation air volume. Several regressors were tested and four of them showed excellent performance: random forest, adaptive boosting, gradient boosting, and decision trees. The latter showed the best regression results, with an R-square value of 0.9998 and a mean square error of 0.0023. The results of this study showed that non-contact spirometry based on a thermal imaging system is feasible and provides all the basic measurements that the conventional spirometers support.
- 12 December 2009
- Published by Springer Nature in Journal of Medical Systems
- Vol. 35 (4) , 723-734
New Automated Detection Method of OSA Based on Artificial Neural Networks Using P-Wave Shape and Time Changes
This paper describes a new method for automatic detection of obstructive sleep apnea (OSA) based on artificial neural networks (ANN) using regular electrocardiogram (ECG) recordings. ECG signals were pre-processed and segmented to extract the P-waves; then three P-wave features were extracted: the P-wave duration (T p ), the P-wave dispersion (P d ), and the time interval from the peak of the P-wave to the R-wave (T pr ). Combinations of the three features were used as features for classification using ANN. For each feature combination studied, 70% of the input data was used for training the ANN, 15% for validating, and 15% for testing the results. Perfect agreement between expert’s scores and the ANN scores was achieved when the ANN was applied on T p , P d , and T pr taken together, while substantial agreements were achieved when applying the ANN on the feature combinations T p and P d , and T p and T pr .
- 12 December 2009
- Published by Springer Nature in Journal of Medical Systems
- Vol. 35 (4) , 723-734
New Automated Detection Method of OSA Based on Artificial Neural Networks Using P-Wave Shape and Time Changes
This paper describes a new method for automatic detection of obstructive sleep apnea (OSA) based on artificial neural networks (ANN) using regular electrocardiogram (ECG) recordings. ECG signals were pre-processed and segmented to extract the P-waves; then three P-wave features were extracted: the P-wave duration (T p ), the P-wave dispersion (P d ), and the time interval from the peak of the P-wave to the R-wave (T pr ). Combinations of the three features were used as features for classification using ANN. For each feature combination studied, 70% of the input data was used for training the ANN, 15% for validating, and 15% for testing the results. Perfect agreement between expert’s scores and the ANN scores was achieved when the ANN was applied on T p , P d , and T pr taken together, while substantial agreements were achieved when applying the ANN on the feature combinations T p and P d , and T p and T pr .
- 10 December 2009
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 48 (3) , 269-276
Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner
This article describes the design, construction, and evaluation of a three-dimensional (3D) ultrasound system to be used for the treatment of kidney tumors using high-intensity focused ultrasound (HIFU). The system consists of a therapeutic ultrasound delivery module (driver, power amplifier, matching circuit, and transducer (1 MHz)) and a 3D positioning module (stepper motors and microcontroller). The system includes software that designs a treatment planning according to the tumor coordinates. In order to verify the capability of the system for moving the transducer, the positioning module was successfully driven to cover cylinders of dimensions as large as 20 cm (diameter) × 10 cm (height) with step sizes as low as 0.05 mm. Several exposimetry experiments were done which showed close match between experimental and theoretical results. Ex vivo experiments were performed and indicated the capability of the system to generate a single lesion of 0.27 cm diameter and 0.45 cm length, as well as five lesions (each with a diameter of 0.3 cm) at prespecified locations. During the ex vivo experiments, temperature monitoring indicated an increase in temperature from 37°C to about 60°C inside the lesion, while outside it the temperature remained below 39°C.
- 10 December 2009
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 48 (3) , 269-276
Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner
This article describes the design, construction, and evaluation of a three-dimensional (3D) ultrasound system to be used for the treatment of kidney tumors using high-intensity focused ultrasound (HIFU). The system consists of a therapeutic ultrasound delivery module (driver, power amplifier, matching circuit, and transducer (1 MHz)) and a 3D positioning module (stepper motors and microcontroller). The system includes software that designs a treatment planning according to the tumor coordinates. In order to verify the capability of the system for moving the transducer, the positioning module was successfully driven to cover cylinders of dimensions as large as 20 cm (diameter) × 10 cm (height) with step sizes as low as 0.05 mm. Several exposimetry experiments were done which showed close match between experimental and theoretical results. Ex vivo experiments were performed and indicated the capability of the system to generate a single lesion of 0.27 cm diameter and 0.45 cm length, as well as five lesions (each with a diameter of 0.3 cm) at prespecified locations. During the ex vivo experiments, temperature monitoring indicated an increase in temperature from 37°C to about 60°C inside the lesion, while outside it the temperature remained below 39°C.
- 27 March 2009
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 47 (6) , 635-640
Optimization of ultrasound array designs for high intensity focused treatment of prostate cancer and benign prostatic hyperplasia
This paper describes the optimization of designing a two-dimensional (2-D) ultrasound phased array to be used for the treatment of both prostate cancer and benign prostatic hyperplasia. The optimization study took into consideration the physical constraints of the conventional method of treatment, and arrived at an optimized array design with the overall dimensions of 10 cm × 2.2 cm. The optimization study also addressed the following additional parameters: The maximum possible depth of penetration (DOP), the maximum possible steering angle, the Grating lobe level, the operating frequency, and the element size. In optimizing the design, the DOP and the steering angle are maximized while the grating lobe value is minimized. A 56 × 12 element 2-D array was found to be the optimum choice allowing both focusing and steering within the entire prostate without inducing damage at locations other than that of the focal point.
- 27 March 2009
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 47 (6) , 635-640
Optimization of ultrasound array designs for high intensity focused treatment of prostate cancer and benign prostatic hyperplasia
This paper describes the optimization of designing a two-dimensional (2-D) ultrasound phased array to be used for the treatment of both prostate cancer and benign prostatic hyperplasia. The optimization study took into consideration the physical constraints of the conventional method of treatment, and arrived at an optimized array design with the overall dimensions of 10 cm × 2.2 cm. The optimization study also addressed the following additional parameters: The maximum possible depth of penetration (DOP), the maximum possible steering angle, the Grating lobe level, the operating frequency, and the element size. In optimizing the design, the DOP and the steering angle are maximized while the grating lobe value is minimized. A 56 × 12 element 2-D array was found to be the optimum choice allowing both focusing and steering within the entire prostate without inducing damage at locations other than that of the focal point.