Zsolt Révay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zsolt Révay has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Tamás Belgya
Centre for Energy Research, Hungarian Academy of Sciences, H-1525 Budapest, Hungary
3 shared publications - László Szentmiklósi
Institute for Energy Security and Environmental Safety
2 shared publications - Zoltán Kis
HUN-REN Centre for Energy Research
2 shared publications Attila Wootsch
1 shared publicationDetre Teschner
1 shared publication- E. A. Mackey
National Institute of Standards and Technology
1 shared publication
Latest Publications
- 1 January 2011
- Published by Springer Nature
- p. 1793-1852
Appendixes – Reference Data to Part III
- 1 January 2011
- Published by Springer Nature
- p. 1619-1672
Neutron-Induced Prompt Gamma Activation Analysis (PGAA)
- 1 January 2011
- Published by Springer Nature
- p. 1619-1672
Neutron-Induced Prompt Gamma Activation Analysis (PGAA)
- 10 July 2009
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (16) , 6851-6859
Determining Elemental Composition Using Prompt γ Activation Analysis
Prompt γ-ray spectra sometimes contain hundreds of characteristic peaks, and the masses of the sample components can be determined from dozens of γ-ray peak areas, some of which are affected by spectral interferences. Reliable qualitative and quantitative analyses can only be performed by using a precisely calibrated detector system, an accurate spectroscopic data library, high-quality spectroscopy software, and a sophisticated method to convert raw data into chemical composition. This article describes the steps of the chemical analysis with prompt γ activation analysis (PGAA). A complete data reduction method has been constructed that handles the large number of spectral peaks using statistical procedures, identifies the chemical components based on statistical criteria, and determines the sample composition with a least-squares fit of the masses calculated from the individual peaks. The calculation of the uncertainties as well as the detection and analytical limits are discussed in detail. The validation of the method is also presented. The method can also be used in the evaluation of the results of other spectroscopic techniques.
- 10 July 2009
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (16) , 6851-6859
Determining Elemental Composition Using Prompt γ Activation Analysis
Prompt γ-ray spectra sometimes contain hundreds of characteristic peaks, and the masses of the sample components can be determined from dozens of γ-ray peak areas, some of which are affected by spectral interferences. Reliable qualitative and quantitative analyses can only be performed by using a precisely calibrated detector system, an accurate spectroscopic data library, high-quality spectroscopy software, and a sophisticated method to convert raw data into chemical composition. This article describes the steps of the chemical analysis with prompt γ activation analysis (PGAA). A complete data reduction method has been constructed that handles the large number of spectral peaks using statistical procedures, identifies the chemical components based on statistical criteria, and determines the sample composition with a least-squares fit of the masses calculated from the individual peaks. The calculation of the uncertainties as well as the detection and analytical limits are discussed in detail. The validation of the method is also presented. The method can also be used in the evaluation of the results of other spectroscopic techniques.
- 28 November 2008
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 278 (3) , 643-646
Recent developments of prompt gamma activation analysis at Budapest
- 28 November 2008
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 278 (3) , 643-646
Recent developments of prompt gamma activation analysis at Budapest
- 1 July 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (15) , 6066-6071
In Situ Determination of Hydrogen Inside a Catalytic Reactor Using Prompt γ Activation Analysis
Prompt γ activation analysis (PGAA) has been further developed to analyze reacting components inside a chemical reactor. The new method, in situ PGAA, was used to determine the hydrogen-to-palladium molar ratio under various conditions of palladium-catalyzed alkyne hydrogenation. The H/Pd molar ratio was successfully measured in the range of 0.1−1.0 in an ∼2-g catalytic reactor containing a few milligrams of palladium catalyst. The amount of hydrogen was only a few tens of micrograms, and the detection limit was ∼5 μg, i.e., at ppm level compared to the whole reactor. The description of the device, methodological developments, a feasibility study, and results of a series of catalytic measurements are presented.
- 1 July 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (15) , 6066-6071
In Situ Determination of Hydrogen Inside a Catalytic Reactor Using Prompt γ Activation Analysis
Prompt γ activation analysis (PGAA) has been further developed to analyze reacting components inside a chemical reactor. The new method, in situ PGAA, was used to determine the hydrogen-to-palladium molar ratio under various conditions of palladium-catalyzed alkyne hydrogenation. The H/Pd molar ratio was successfully measured in the range of 0.1−1.0 in an ∼2-g catalytic reactor containing a few milligrams of palladium catalyst. The amount of hydrogen was only a few tens of micrograms, and the detection limit was ∼5 μg, i.e., at ppm level compared to the whole reactor. The description of the device, methodological developments, a feasibility study, and results of a series of catalytic measurements are presented.
- 2 May 2008
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 276 (3) , 825-830
Prompt gamma activation analysis of samples in thick containers
- 2 May 2008
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 276 (3) , 825-830
Prompt gamma activation analysis of samples in thick containers