Michael R. Isley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael R. Isley has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Harvey L. Edmonds
University of Louisville School of Medicine
1 shared publicationJeffrey R. Balzer
1 shared publication- Mark M. Stecker
Fresno Institute of Neuroscience, Fresno, CA 93730, USA
1 shared publication Ronald E. Leppanen
Knoxville Neurology Clinic and Child Neurology Services Knoxville, Tennessee
1 shared publicationXiao-Feng Zhang
1 shared publication
Latest Publications
- 1 June 2012
- Published by Taylor & Francis in The Neurodiagnostic Journal
- Vol. 52 (2) , 100-175
Current Trends in Pedicle Screw Stimulation Techniques: Lumbosacral, Thoracic, and Cervical Levels
Unequivocally, pedicle screw instrumentation has evolved as a primary construct for the treatment of both common and complex spinal disorders. However an inevitable and potentially major complication associated with this type of surgery is misplacement of a pedicle screw(s) which may result in neural and vascular complications, as well as impair the biomechanical stability of the spinal instrumentation resulting in loss of fixation. In light of these potential surgical complications, critical reviews of outcome data for treatment of chronic, low-back pain using pedicle screw instrumentation concluded that "pedicle screw fixation improves radiographically demonstrated fusion rates;" however the expense and complication rates for such constructs are considerable in light of the clinical benefit (Resnick et al. 2005a). Currently, neuromonitoring using free-run and evoked (triggered) electromyography (EMG) is widely used and advocated for safer and more accurate placement of pedicle screws during open instrumentation procedures, and more recently, guiding percutaneous placement (minimally invasive) where the pedicle cannot be easily inspected visually. The latter technique, evoked or triggered EMG when applied to pedicle screw instrumentation surgeries, has been referred to as the pedicle screw stimulation technique. As concluded in the Position Statement by the American Society of Neurophysiological Monitoring (ASNM), multimodality neuromonitoring using free-run EMG and the pedicle screw stimulation technique was considered a practice option and not yet a standard of care (Leppanen 2005). Subsequently, the American Association of Neurological Surgeons/Congress of Neurological Surgeons (AANS/CNS) Joint Section on Disorders of the Spine and Peripheral Nerves published their "Guidelines for the Performance of Fusion Procedures for Degenerative Disease of the Lumbar Spine" (Heary 2005, Resnick et al. 2005a, Resnick et al. 2005b). It was concluded that the "primary justification" of intraoperative neuromonitoring"... is the perception that the safety and efficacy of pedicle screw fixation are enhanced..." (Resnick et al. 2005b). However in summarizing a massive (over 1000 papers taken from the National Library of Medicine), contemporary, literature review spanning nearly a decade (1996 to 2003), this invited panel (Resnick et al. 2005b) recognized that the evidence-based documents contributing to the parts related to pedicle screw fixation and neuromonitoring were "... full of potential sources of error ..." and lacked appropriate, randomized, prospective studies for formulating rigid standards and guidelines. Nevertheless, current trends support the routine use and clinical utility of these neuromonitoring techniques. In particular free-run and triggered EMG have been well recognized in numerous publications for improving both the accuracy and safety of pedicle screw implantation. Currently, treatment with pedicle screw instrumentation routinely involves all levels of the spine - lumbosacral, thoracic, and cervical. Significant historical events, various neuromonitoring modalities, intraoperative alarm criteria, clinical efficacy, current trends, and caveats related to pedicle screw stimulation along the entire vertebral column will be reviewed.
- 1 June 2012
- Published by Taylor & Francis in The Neurodiagnostic Journal
- Vol. 52 (2) , 100-175
Current Trends in Pedicle Screw Stimulation Techniques: Lumbosacral, Thoracic, and Cervical Levels
Unequivocally, pedicle screw instrumentation has evolved as a primary construct for the treatment of both common and complex spinal disorders. However an inevitable and potentially major complication associated with this type of surgery is misplacement of a pedicle screw(s) which may result in neural and vascular complications, as well as impair the biomechanical stability of the spinal instrumentation resulting in loss of fixation. In light of these potential surgical complications, critical reviews of outcome data for treatment of chronic, low-back pain using pedicle screw instrumentation concluded that "pedicle screw fixation improves radiographically demonstrated fusion rates;" however the expense and complication rates for such constructs are considerable in light of the clinical benefit (Resnick et al. 2005a). Currently, neuromonitoring using free-run and evoked (triggered) electromyography (EMG) is widely used and advocated for safer and more accurate placement of pedicle screws during open instrumentation procedures, and more recently, guiding percutaneous placement (minimally invasive) where the pedicle cannot be easily inspected visually. The latter technique, evoked or triggered EMG when applied to pedicle screw instrumentation surgeries, has been referred to as the pedicle screw stimulation technique. As concluded in the Position Statement by the American Society of Neurophysiological Monitoring (ASNM), multimodality neuromonitoring using free-run EMG and the pedicle screw stimulation technique was considered a practice option and not yet a standard of care (Leppanen 2005). Subsequently, the American Association of Neurological Surgeons/Congress of Neurological Surgeons (AANS/CNS) Joint Section on Disorders of the Spine and Peripheral Nerves published their "Guidelines for the Performance of Fusion Procedures for Degenerative Disease of the Lumbar Spine" (Heary 2005, Resnick et al. 2005a, Resnick et al. 2005b). It was concluded that the "primary justification" of intraoperative neuromonitoring"... is the perception that the safety and efficacy of pedicle screw fixation are enhanced..." (Resnick et al. 2005b). However in summarizing a massive (over 1000 papers taken from the National Library of Medicine), contemporary, literature review spanning nearly a decade (1996 to 2003), this invited panel (Resnick et al. 2005b) recognized that the evidence-based documents contributing to the parts related to pedicle screw fixation and neuromonitoring were "... full of potential sources of error ..." and lacked appropriate, randomized, prospective studies for formulating rigid standards and guidelines. Nevertheless, current trends support the routine use and clinical utility of these neuromonitoring techniques. In particular free-run and triggered EMG have been well recognized in numerous publications for improving both the accuracy and safety of pedicle screw implantation. Currently, treatment with pedicle screw instrumentation routinely involves all levels of the spine - lumbosacral, thoracic, and cervical. Significant historical events, various neuromonitoring modalities, intraoperative alarm criteria, clinical efficacy, current trends, and caveats related to pedicle screw stimulation along the entire vertebral column will be reviewed.
- 16 September 2009
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 23 (6) , 369-390
Guidelines for intraoperative neuromonitoring using raw (analog or digital waveforms) and quantitative electroencephalography: a position statement by the American Society of Neurophysiological Monitoring
Electroencephalography (EEG) is one of the oldest and most commonly utilized modalities for intraoperative neuromonitoring. Historically, interest in the EEG patterns associated with anesthesia is as old as the discovery of the EEG itself. The evolution of its intraoperative use was also expanded to include monitoring for assessing cortical perfusion and oxygenation during a variety of vascular, cardiac, and neurosurgical procedures. Furthermore, a number of quantitative or computer-processed algorithms have also been developed to aid in its visual representation and interpretation. The primary clinical outcomes for which modern EEG technology has made significant intraoperative contributions include: (1) recognizing and/or preventing perioperative ischemic insults, and (2) monitoring of brain function for anesthetic drug administration in order to determine depth of anesthesia (and level of consciousness), including the tailoring of drug levels to achieve a predefined neural effect (e.g., burst suppression). While the accelerated development of microprocessor technologies has fostered an extraordinarily rapid growth in the use of intraoperative EEG, there is still no universal adoption of a monitoring technique(s) or of criteria for its neural end-point(s) by anesthesiologists, surgeons, neurologists, and neurophysiologists. One of the most important limitations to routine intraoperative use of EEG may be the lack of standardization of methods, alarm criteria, and recommendations related to its application. Lastly, refinements in technology and signal processing can be expected to advance the usefulness of the intraoperative EEG for both anesthetic and surgical management of patients.
- 16 September 2009
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 23 (6) , 369-390
Guidelines for intraoperative neuromonitoring using raw (analog or digital waveforms) and quantitative electroencephalography: a position statement by the American Society of Neurophysiological Monitoring
Electroencephalography (EEG) is one of the oldest and most commonly utilized modalities for intraoperative neuromonitoring. Historically, interest in the EEG patterns associated with anesthesia is as old as the discovery of the EEG itself. The evolution of its intraoperative use was also expanded to include monitoring for assessing cortical perfusion and oxygenation during a variety of vascular, cardiac, and neurosurgical procedures. Furthermore, a number of quantitative or computer-processed algorithms have also been developed to aid in its visual representation and interpretation. The primary clinical outcomes for which modern EEG technology has made significant intraoperative contributions include: (1) recognizing and/or preventing perioperative ischemic insults, and (2) monitoring of brain function for anesthetic drug administration in order to determine depth of anesthesia (and level of consciousness), including the tailoring of drug levels to achieve a predefined neural effect (e.g., burst suppression). While the accelerated development of microprocessor technologies has fostered an extraordinarily rapid growth in the use of intraoperative EEG, there is still no universal adoption of a monitoring technique(s) or of criteria for its neural end-point(s) by anesthesiologists, surgeons, neurologists, and neurophysiologists. One of the most important limitations to routine intraoperative use of EEG may be the lack of standardization of methods, alarm criteria, and recommendations related to its application. Lastly, refinements in technology and signal processing can be expected to advance the usefulness of the intraoperative EEG for both anesthetic and surgical management of patients.