Silvia Dulanská
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Silvia Dulanská has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
Boris Remenec
Department of Nuclear Chemistry, Faculty of Natural Sciences, Comenius University, Mlynska Dolina, Ilkovičova 6, 842 15, Bratislava, Slovakia
29 shared publicationsĽubomír Mátel
Department of Nuclear Chemistry, Faculty of Natural Sciences, Comenius University, Mlynska Dolina, Ilkovičova 6, 842 15, Bratislava, Slovakia
22 shared publicationsDušan Galanda
Department of Nuclear Chemistry, Faculty of Natural Sciences, Comenius University, Bratislava, Slovakia
10 shared publications- Ján Bilohuščin
Comenius University
5 shared publications Veronika Gardoňová
Comenius University
5 shared publicationsBianka Horváthová
Department of Nuclear Chemistry, Faculty of Natural Sciences, Comenius University, Mlynska Dolina, Ilkovičova 6, 842 15, Bratislava, Slovakia
4 shared publications
Latest Publications
- Open Access
- 3 August 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (12)
Strontium-90 determination in milk ash by cherenkov and gas-flow proportional counting: A comparison of three radiochemical separations
- 3 August 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (12)
Open AccessStrontium-90 determination in milk ash by cherenkov and gas-flow proportional counting: A comparison of three radiochemical separations
- Open Access
Segmentation and Multimodal Characterization of Metal Particles in the Human Hippocampus Using Discrete Segmentation Algorithms and Correlation Spectral Analysis
The accumulation of metallic micro- and nanoparticles in the human hippocampus is increasingly linked to neurotoxic processes and neurodegenerative disorders. Precise segmentation and detailed characterization of these particles are crucial to understanding their role. This study presents a novel method that combines discrete segmentation based on graph-cut theory with Dinic’s algorithm for the computation of maximum flow. The images are modeled as directed weighted graphs, with pixel intensities and gradients defining edge capacities, enabling robust segmentation in electron microscopy data. To ensure robustness, the method is validated against ground-truth masks, achieving a Dice coefficient of 0.97898 ± 0.0172 and an Intersection over Union (IoU) of 0.9609 ± 0.0326. Morphometric parameters—area, perimeter, circularity, and Feret diameters—are automatically extracted. Concurrently, elemental analysis using Energy-Dispersive X-ray Spectroscopy (EDS) reveals a heterogeneous composition, including iron-rich particles and compounds containing nickel and chromium. The observed variability highlights the importance of single-particle analysis in better understanding the neurobiological impact of metallic deposits.
Open AccessSegmentation and Multimodal Characterization of Metal Particles in the Human Hippocampus Using Discrete Segmentation Algorithms and Correlation Spectral Analysis
The accumulation of metallic micro- and nanoparticles in the human hippocampus is increasingly linked to neurotoxic processes and neurodegenerative disorders. Precise segmentation and detailed characterization of these particles are crucial to understanding their role. This study presents a novel method that combines discrete segmentation based on graph-cut theory with Dinic’s algorithm for the computation of maximum flow. The images are modeled as directed weighted graphs, with pixel intensities and gradients defining edge capacities, enabling robust segmentation in electron microscopy data. To ensure robustness, the method is validated against ground-truth masks, achieving a Dice coefficient of 0.97898 ± 0.0172 and an Intersection over Union (IoU) of 0.9609 ± 0.0326. Morphometric parameters—area, perimeter, circularity, and Feret diameters—are automatically extracted. Concurrently, elemental analysis using Energy-Dispersive X-ray Spectroscopy (EDS) reveals a heterogeneous composition, including iron-rich particles and compounds containing nickel and chromium. The observed variability highlights the importance of single-particle analysis in better understanding the neurobiological impact of metallic deposits.
- Open Access
- 13 November 2025
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 65 (1) , 1-9
Application of KMnO4-modified fly ash sorbent for 226Ra dose evaluation in bottled mineral waters in Slovakia
Monitoring of 226 Ra in drinking water is critical due to its radiotoxicity and potential health risks. This study presents a novel method for 226 Ra determination in bottled mineral waters using a KMnO 4 -modified fly ash sorbent. The sorbent, prepared by manganese dioxide surface modification, demonstrated significantly enhanced radium sorption capacity. Method validation, including linear regression and equivalence tests, confirmed that the modified fly ash sorbent and commercial MnO 2 -PAN resin yield statistically equivalent results for 226 Ra determination in mineral waters. Thus, it is concluded that application of the modified sorbent represents a reliable and cost-effective alternative to commercial methods. Application to 20 commercially available Slovak bottled mineral waters revealed 226 Ra activity concentrations corresponding to annual committed effective doses ranging from 1 to 154 µSv/y. While the average dose (41.8 µSv/y) remained well below national and international safety limits, three samples exceeded the Slovak regulatory threshold of 100 µSv/y. These findings emphasize the need for ongoing monitoring and demonstrate the suitability of the KMnO 4 -modified fly ash sorbent for routine radiological quality control of bottled mineral waters.
- 13 November 2025
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 65 (1) , 1-9
Open AccessApplication of KMnO4-modified fly ash sorbent for 226Ra dose evaluation in bottled mineral waters in Slovakia
Monitoring of 226 Ra in drinking water is critical due to its radiotoxicity and potential health risks. This study presents a novel method for 226 Ra determination in bottled mineral waters using a KMnO 4 -modified fly ash sorbent. The sorbent, prepared by manganese dioxide surface modification, demonstrated significantly enhanced radium sorption capacity. Method validation, including linear regression and equivalence tests, confirmed that the modified fly ash sorbent and commercial MnO 2 -PAN resin yield statistically equivalent results for 226 Ra determination in mineral waters. Thus, it is concluded that application of the modified sorbent represents a reliable and cost-effective alternative to commercial methods. Application to 20 commercially available Slovak bottled mineral waters revealed 226 Ra activity concentrations corresponding to annual committed effective doses ranging from 1 to 154 µSv/y. While the average dose (41.8 µSv/y) remained well below national and international safety limits, three samples exceeded the Slovak regulatory threshold of 100 µSv/y. These findings emphasize the need for ongoing monitoring and demonstrate the suitability of the KMnO 4 -modified fly ash sorbent for routine radiological quality control of bottled mineral waters.
- Open Access
- 12 December 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 64 (1) , 191-200
Determination of activities of 210Pb in Slovak tobacco and cigarettes: a study on radiological risks
This study investigates the 210Pb activity concentrations in tobacco and cigarettes available in Slovakia, utilizing two specific extraction methods including the Sr Resin sorbent used in extraction chromatography, and the AnaLig Sr01 sorbent, which operates based on molecular recognition principles. The findings revealed significant variations in 210Pb activity concentrations, with concentrations ranging from 13.3 to 33.8 mBq/g in tobacco, and from 16.8 to 28.5 mBq/g in cigarettes. The average 210Pb activity per cigarette was 14.4 mBq ± 1.7 mBq. Annual effective doses for smokers were calculated, with values for tobacco ranging from 27.9 to 126.7 µSv and for cigarettes from 25.5 to 115.7 µSv. The study highlights the importance of comparing these two methods to ensure an accurate assessment of 210Pb exposure and evaluation of radiological risks associated with smoking in Slovakia.
- 12 December 2024
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 64 (1) , 191-200
Open AccessDetermination of activities of 210Pb in Slovak tobacco and cigarettes: a study on radiological risks
This study investigates the 210Pb activity concentrations in tobacco and cigarettes available in Slovakia, utilizing two specific extraction methods including the Sr Resin sorbent used in extraction chromatography, and the AnaLig Sr01 sorbent, which operates based on molecular recognition principles. The findings revealed significant variations in 210Pb activity concentrations, with concentrations ranging from 13.3 to 33.8 mBq/g in tobacco, and from 16.8 to 28.5 mBq/g in cigarettes. The average 210Pb activity per cigarette was 14.4 mBq ± 1.7 mBq. Annual effective doses for smokers were calculated, with values for tobacco ranging from 27.9 to 126.7 µSv and for cigarettes from 25.5 to 115.7 µSv. The study highlights the importance of comparing these two methods to ensure an accurate assessment of 210Pb exposure and evaluation of radiological risks associated with smoking in Slovakia.
- Open Access
- 2 July 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 333 (11) , 5713-5720
Comparative analysis of AnaLig Sr01 and Sr Resin methods for 210Pb determination in tobacco using TriCarb 3100 TR spectrometry: a statistical approach to accuracy and efficiency
This study aims to statistically compare two methods for determining 210Pb in tobacco: the molecular recognition sorbent method (AnaLig Sr01) and the extraction chromatography sorbent method (Sr Resin). The TriCarb 3100 TR liquid scintillation spectrometer was used to measure and determine 210Pb activity in the tobacco solution. Statistical analysis confirmed the accuracy and precision of the 210Pb measurements, with high detection efficiencies of 82% for both AnaLig Sr01 and Sr Resin. The linear model demonstrated that the residuals followed the Gaussian model, without any autocorrelation or trend. Paired t tests showed consistent results across all methods, and all solid-phase extraction methods proved efficient for 210Pb separations in tobacco samples. These findings provide support for the suitability of both methods and lay a foundation for future articles on tobacco and cigarette samples.
- 2 July 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 333 (11) , 5713-5720
Open AccessComparative analysis of AnaLig Sr01 and Sr Resin methods for 210Pb determination in tobacco using TriCarb 3100 TR spectrometry: a statistical approach to accuracy and efficiency
This study aims to statistically compare two methods for determining 210Pb in tobacco: the molecular recognition sorbent method (AnaLig Sr01) and the extraction chromatography sorbent method (Sr Resin). The TriCarb 3100 TR liquid scintillation spectrometer was used to measure and determine 210Pb activity in the tobacco solution. Statistical analysis confirmed the accuracy and precision of the 210Pb measurements, with high detection efficiencies of 82% for both AnaLig Sr01 and Sr Resin. The linear model demonstrated that the residuals followed the Gaussian model, without any autocorrelation or trend. Paired t tests showed consistent results across all methods, and all solid-phase extraction methods proved efficient for 210Pb separations in tobacco samples. These findings provide support for the suitability of both methods and lay a foundation for future articles on tobacco and cigarette samples.
- Open Access
- 30 November 2021
- Published by University of Saints Cyril and Methodius in Nova Biotechnologica et Chimica
- Vol. 20 (2) , e1258
Municipal sewage sludge as a source of microelements in sustainable plant production: a laboratory lysimeter study
The aim of the work was to characterize the samples of sewage sludge (SSL) originated from the Wastewater Treatment Plant Piešťany (TAVOS, a.s., Trnava, Slovakia) in terms of their potential application into the soils. Within the physico-chemical characterization of SSL, the samples were analysed in terms of the values of pH, cation exchange capacity (CEC), total organic carbon (TOC), water holding capacity (WHC), as well as the presence of heavy metals. It was found that SSL contained significant amounts of microelements Zn (1,269 mg.kg-1, d.w.) and Cu (224 mg.kg-1, d.w.). Laboratory lysimeter experiments involving the application of SSL into the top layer of agriculturally used soil (0 – 10 cm) forming a soil column, in which seedlings of tobacco (Nicotiana tabacum L.) were cultivated, showed that in the case of SSL application in the highest permitted amounts (15 t.ha-1) only 0.11 % Zn and 0.07 % Cu were released into the soil eluate during a 28 day of exposure, while in tobacco plants 0.13 % Zn and 0.05 % Cu were accumulated from the total amount of Zn and Cu originated from the application of SSL (Zn – 133 mg and Cu – 23.5 mg). When applying SSL in amount 30 t.ha-1 i.e., in the dose exceeding the permitted limits, only 0.02 % Zn and 0.04 % Cu were released into the soil eluate and 0.16 % Zn and 0.09 % Cu were accumulated in tobacco plants from the applied amount of SSL (Zn – 267 mg and Cu – 47.0 mg).
- 30 November 2021
- Published by University of Saints Cyril and Methodius in Nova Biotechnologica et Chimica
- Vol. 20 (2) , e1258
Open AccessMunicipal sewage sludge as a source of microelements in sustainable plant production: a laboratory lysimeter study
The aim of the work was to characterize the samples of sewage sludge (SSL) originated from the Wastewater Treatment Plant Piešťany (TAVOS, a.s., Trnava, Slovakia) in terms of their potential application into the soils. Within the physico-chemical characterization of SSL, the samples were analysed in terms of the values of pH, cation exchange capacity (CEC), total organic carbon (TOC), water holding capacity (WHC), as well as the presence of heavy metals. It was found that SSL contained significant amounts of microelements Zn (1,269 mg.kg-1, d.w.) and Cu (224 mg.kg-1, d.w.). Laboratory lysimeter experiments involving the application of SSL into the top layer of agriculturally used soil (0 – 10 cm) forming a soil column, in which seedlings of tobacco (Nicotiana tabacum L.) were cultivated, showed that in the case of SSL application in the highest permitted amounts (15 t.ha-1) only 0.11 % Zn and 0.07 % Cu were released into the soil eluate during a 28 day of exposure, while in tobacco plants 0.13 % Zn and 0.05 % Cu were accumulated from the total amount of Zn and Cu originated from the application of SSL (Zn – 133 mg and Cu – 23.5 mg). When applying SSL in amount 30 t.ha-1 i.e., in the dose exceeding the permitted limits, only 0.02 % Zn and 0.04 % Cu were released into the soil eluate and 0.16 % Zn and 0.09 % Cu were accumulated in tobacco plants from the applied amount of SSL (Zn – 267 mg and Cu – 47.0 mg).
- 1 June 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 148, 35-39
Determination of 79Se using a volatilisation method and liquid scintillation spectrometry
- 1 June 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 148, 35-39
Determination of 79Se using a volatilisation method and liquid scintillation spectrometry
- 1 October 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 140, 96-101
Preparation and characterization of MnO2- SiO2 composite resin for 226Ra pre-concentration in water samples
- 1 October 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 140, 96-101
Preparation and characterization of MnO2- SiO2 composite resin for 226Ra pre-concentration in water samples
- 1 January 2018
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 181, 18-31
Comparison of different methodologies for the 90 Sr determination in environmental samples
- 1 January 2018
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 181, 18-31
Comparison of different methodologies for the 90 Sr determination in environmental samples
- 1 May 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 123, 128-132
Development of 126 Sn separation method by means of anion exchange resin and gamma spectroscopy
- 1 May 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 123, 128-132
Development of 126 Sn separation method by means of anion exchange resin and gamma spectroscopy