Bağdagül Helvacıoğlu Kıvanç
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bağdagül Helvacıoğlu Kıvanç has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Hacer Deniz Arisu
Faculty of Dentistry, Department of Restorative Dentistry, Gazi University, Ankara, Turkey
5 shared publications Güliz Görgül
2 shared publications- Adil Ekici1 shared publication
Baran C Sağlam
1 shared publicationBaran C.
1 shared publicationBağdagül Helvacıoğlu
1 shared publication
Latest Publications
- Open Access
- 1 August 2018
- Published by IntechOpen
The Permanent Maxillary and Mandibular Premolar Teeth
The permanent premolar teeth are placed between the anterior teeth and molars. Eight premolars are found in the permanent dentition, four per arch and two in each quadrant. The main function of premolars is to assist the canines in regard to tear and pierce the food and supplement the grinding of the molars during mastication. The other functions are to support the corners of the mouth reinforce esthetics during smiling and maintain the vertical dimension. Detailed morphology of the permanent premolar teeth is narrated in a pointwise and systematic manner in this chapter.
- 1 August 2018
- Published by IntechOpen
Open AccessThe Permanent Maxillary and Mandibular Premolar Teeth
The permanent premolar teeth are placed between the anterior teeth and molars. Eight premolars are found in the permanent dentition, four per arch and two in each quadrant. The main function of premolars is to assist the canines in regard to tear and pierce the food and supplement the grinding of the molars during mastication. The other functions are to support the corners of the mouth reinforce esthetics during smiling and maintain the vertical dimension. Detailed morphology of the permanent premolar teeth is narrated in a pointwise and systematic manner in this chapter.
- Open Access
- 19 October 2016
- Published by IntechOpen
Fracture Mechanics in Adhesive Dentistry
Fracture Mechanics in Adhesive Dentistry | InTechOpen, Published on: 2016-10-19. Authors: Mügem Aslı Gürel, Bağdagül Helvacıoğlu Kıvanç and Hacer Deniz Arısu
- 19 October 2016
- Published by IntechOpen
Open AccessFracture Mechanics in Adhesive Dentistry
Fracture Mechanics in Adhesive Dentistry | InTechOpen, Published on: 2016-10-19. Authors: Mügem Aslı Gürel, Bağdagül Helvacıoğlu Kıvanç and Hacer Deniz Arısu
- Open Access
- 26 June 2015
- Published by Springer Nature in BMC Oral Health
- Vol. 15 (1) , 71
Apical extrusion of sodium hypochlorite activated with two laser systems and ultrasonics: a spectrophotometric analysis
The aim of the present study was to compare the effect of ultrasonically or laser (Nd:YAG or diode) activated irrigation on the irrigating solution extrusion compared to non-activated syringe irrigation. Extracted mandibular premolar teeth (n = 48) with single canals were instrumented. The teeth were secured through the lid of an Eppendorf tube filled with 1.0 mL distilled water to collect the apically extruded irrigating solution. The teeth were randomly divided into four groups: non-activated syringe irrigation, diode laser, Nd:YAG laser and passive ultrasonic irrigation (PUI) using 2 % NaOCl. The irrigating solution extruded through the apical foramen was collected in the Eppendorf tube and evaluated by a chemical reaction with using a spectrophotometer. The data was analyzed using one-way ANOVA and Tukey’s post hoc test (α = 0.05). All the groups showed apically extruded irrigating solution. There were significant differences among the groups (p < 0.05). Nd:YAG laser activated irrigation showed greater extrusion (p < 0.05), while the non-activated syringe irrigation showed less extrusion (p < 0.05). Only the difference between diode laser and PUI was not statistically significant (p > 0.05). Within the limitations of this in vitro study, the researchers concluded that non-activated syringe irrigation caused less apically extruded irrigating solution than PUI and LAI using Nd:YAG or diode lasers.
- 26 June 2015
- Published by Springer Nature in BMC Oral Health
- Vol. 15 (1) , 71
Open AccessApical extrusion of sodium hypochlorite activated with two laser systems and ultrasonics: a spectrophotometric analysis
The aim of the present study was to compare the effect of ultrasonically or laser (Nd:YAG or diode) activated irrigation on the irrigating solution extrusion compared to non-activated syringe irrigation. Extracted mandibular premolar teeth (n = 48) with single canals were instrumented. The teeth were secured through the lid of an Eppendorf tube filled with 1.0 mL distilled water to collect the apically extruded irrigating solution. The teeth were randomly divided into four groups: non-activated syringe irrigation, diode laser, Nd:YAG laser and passive ultrasonic irrigation (PUI) using 2 % NaOCl. The irrigating solution extruded through the apical foramen was collected in the Eppendorf tube and evaluated by a chemical reaction with using a spectrophotometer. The data was analyzed using one-way ANOVA and Tukey’s post hoc test (α = 0.05). All the groups showed apically extruded irrigating solution. There were significant differences among the groups (p < 0.05). Nd:YAG laser activated irrigation showed greater extrusion (p < 0.05), while the non-activated syringe irrigation showed less extrusion (p < 0.05). Only the difference between diode laser and PUI was not statistically significant (p > 0.05). Within the limitations of this in vitro study, the researchers concluded that non-activated syringe irrigation caused less apically extruded irrigating solution than PUI and LAI using Nd:YAG or diode lasers.
- Open Access
- 1 January 2013
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 5 (3) , 305-311
The effect of different adhesive system applications on push-out bond strengths of glass fiber posts
Helvacıoğlu Kıvanç B, et al. J Adv Prosthodont. 2013 Aug;5(3):305-311. http://dx.doi.org/10.4047/jap.2013.5.3.305
- 1 January 2013
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 5 (3) , 305-311
Open AccessThe effect of different adhesive system applications on push-out bond strengths of glass fiber posts
Helvacıoğlu Kıvanç B, et al. J Adv Prosthodont. 2013 Aug;5(3):305-311. http://dx.doi.org/10.4047/jap.2013.5.3.305
- 24 October 2010
- Published by Wiley in Australian Endodontic Journal
- Vol. 39 (1) , 19-24
Effect of post‐space treatments on the push‐out bond strength and failure modes of glass fibre posts
The aim of this study was to evaluate the effect of different post‐space treatments on the push‐out bond strength and failure modes of glass fibre posts. Forty mandibular premolar roots were cut and endodontically treated. Post spaces were prepared and roots were divided into four groups. In group 1 distilled water irrigation (control), in group 2 2.25% NaOCl irrigation, in group 3 2.25% NaOCl + 17% EDTA irrigation were done and in group 4 diode laser was applied to the prepared post spaces. Scanning electron microscope (SEM) analysis was made for each group. Fibre posts were then luted with resin cement. Each root was prepared for push‐out test. Data were statistically analysed with anova (P = 0.05). After push‐out test, the failure modes were observed but not statistically analysed. There were statistically significant differences between Group 3 and Group 2 in both regions (P < 0.05), also in the middle region of Group 4 and Group 2 (P < 0.05). Cervical root segments showed higher bond strengths than middle ones in all groups (P < 0.05). The highest bond strength values were obtained from NaOCl/EDTA and the lowest bond strength values were obtained from NaOCl for both regions.
- 24 October 2010
- Published by Wiley in Australian Endodontic Journal
- Vol. 39 (1) , 19-24
Effect of post‐space treatments on the push‐out bond strength and failure modes of glass fibre posts
The aim of this study was to evaluate the effect of different post‐space treatments on the push‐out bond strength and failure modes of glass fibre posts. Forty mandibular premolar roots were cut and endodontically treated. Post spaces were prepared and roots were divided into four groups. In group 1 distilled water irrigation (control), in group 2 2.25% NaOCl irrigation, in group 3 2.25% NaOCl + 17% EDTA irrigation were done and in group 4 diode laser was applied to the prepared post spaces. Scanning electron microscope (SEM) analysis was made for each group. Fibre posts were then luted with resin cement. Each root was prepared for push‐out test. Data were statistically analysed with anova (P = 0.05). After push‐out test, the failure modes were observed but not statistically analysed. There were statistically significant differences between Group 3 and Group 2 in both regions (P < 0.05), also in the middle region of Group 4 and Group 2 (P < 0.05). Cervical root segments showed higher bond strengths than middle ones in all groups (P < 0.05). The highest bond strength values were obtained from NaOCl/EDTA and the lowest bond strength values were obtained from NaOCl for both regions.
- 1 January 2010
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 29 (3) , 262-267
Fracture resistance of premolars with one remaining cavity wall restored using different techniques
The aim of the study was to compare the fracture resistance of maxillary premolars with one remaining cavity wall restored using different post systems. Forty-eight maxillary premolars were endodontically treated and randomly assigned to four groups for postcore restoration. The first three test groups were restored with polyethylene woven fiber posts, custom-made glass fiber-reinforced composite posts, and titanium posts respectively. In the control Group 4, standardized cavities (3.5×1.5 mm) were prepared in the palatal canal entrance and filled with a resin composite. All the specimens were then restored with a resin composite crown seated on the post. Load was applied with a stainless steel ball (1 mm/min), and the failure modes of all specimens were evaluated. There were no significant differences in fracture resistance and failure mode among the different restorative materials (p>0.05). Within the limitations of this in vitro study, it was concluded that the presence and type of post did not influence the fracture load and failure mode of maxillary premolar teeth with one remaining cavity wall.
- 1 January 2010
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 29 (3) , 262-267
Fracture resistance of premolars with one remaining cavity wall restored using different techniques
The aim of the study was to compare the fracture resistance of maxillary premolars with one remaining cavity wall restored using different post systems. Forty-eight maxillary premolars were endodontically treated and randomly assigned to four groups for postcore restoration. The first three test groups were restored with polyethylene woven fiber posts, custom-made glass fiber-reinforced composite posts, and titanium posts respectively. In the control Group 4, standardized cavities (3.5×1.5 mm) were prepared in the palatal canal entrance and filled with a resin composite. All the specimens were then restored with a resin composite crown seated on the post. Load was applied with a stainless steel ball (1 mm/min), and the failure modes of all specimens were evaluated. There were no significant differences in fracture resistance and failure mode among the different restorative materials (p>0.05). Within the limitations of this in vitro study, it was concluded that the presence and type of post did not influence the fracture load and failure mode of maxillary premolar teeth with one remaining cavity wall.
- 8 October 2009
- Published by Wiley in International Endodontic Journal
- Vol. 42 (11) , 997-1003
Fracture resistance of thin‐walled roots restored with different post systems
Aim To compare the fracture resistance of thin‐walled roots after restoration with different types of post systems.Methodology One hundred and sixty‐five decoronated maxillary central incisors were root filled and randomly assigned to three groups with respect to the remaining dentine thickness of root (1.0 mm, 1.5 mm, 2.0 mm). Each group was randomly divided into five equal subgroups. The subgroups were restored with one of the following post systems: polyethylene woven fibre (R), composite resin cured by light‐transmitting post + glass fibre post (L), electrical glass fibre post (E), composite corono‐radicular restoration (C) and cast metal post (M). Standard cores were constructed using composite resin in the first four groups. The samples were subjected to a gradually increasing force (1 mm min−1). The force required to fracture was recorded. The data was analysed with anova and Tukey test (P = 0.05).Results The cast metal post group had the highest fracture strength (P < 0.001). There was no significant difference in fracture resistance between the other four groups. Fracture resistance was affected largely by the remaining dentine thickness in fibre post groups; however, the difference was not significant. On the contrary in the cast metal post group load failure was inversely influenced by axio‐proximal dimension of dentine walls.Conclusion The cast post group had a higher fracture strength than resin groups. The force required to fracture the roots was similar for all fibre post systems and for all dentine thicknesses.
- 8 October 2009
- Published by Wiley in International Endodontic Journal
- Vol. 42 (11) , 997-1003
Fracture resistance of thin‐walled roots restored with different post systems
Aim To compare the fracture resistance of thin‐walled roots after restoration with different types of post systems.Methodology One hundred and sixty‐five decoronated maxillary central incisors were root filled and randomly assigned to three groups with respect to the remaining dentine thickness of root (1.0 mm, 1.5 mm, 2.0 mm). Each group was randomly divided into five equal subgroups. The subgroups were restored with one of the following post systems: polyethylene woven fibre (R), composite resin cured by light‐transmitting post + glass fibre post (L), electrical glass fibre post (E), composite corono‐radicular restoration (C) and cast metal post (M). Standard cores were constructed using composite resin in the first four groups. The samples were subjected to a gradually increasing force (1 mm min−1). The force required to fracture was recorded. The data was analysed with anova and Tukey test (P = 0.05).Results The cast metal post group had the highest fracture strength (P < 0.001). There was no significant difference in fracture resistance between the other four groups. Fracture resistance was affected largely by the remaining dentine thickness in fibre post groups; however, the difference was not significant. On the contrary in the cast metal post group load failure was inversely influenced by axio‐proximal dimension of dentine walls.Conclusion The cast post group had a higher fracture strength than resin groups. The force required to fracture the roots was similar for all fibre post systems and for all dentine thicknesses.