Jiri Janda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jiri Janda has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Daniel Sas
University of Defence
5 shared publications- Daniel Sas
Military University
4 shared publications Erik Rajchl
University of Defence, NBC Defence Institute, Vyskov, Czech Republic
3 shared publications- Jaroslav Jánský
Department of Physics Faculty of Electrical Engineering and Communication Brno University of Technology Brno Czech Republic
3 shared publications Lucie Fiserova
NUVIA a. s., Trebic, Czech Republic
3 shared publications- Lucie Fiserova
NUVIA a.s.
3 shared publications
Latest Publications
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (5) , 1091-1099
The Influence of Oxygen on Pulse Shape Discrimination at Various Solvents and Phosphors
In this work, the issue of oxygen quenching on the PSD ability/quality of liquid scintillation cocktails is addressed throughout the investigation of the effect of different solvents on PSD quality and light yield using different concentrations of the phosphor PPO+MSB. Two different atmospheric conditions were in the preparation of the samples, one consisted of air at standard temperature and pressure (STP) and the other was nitrogen. The second part of the work is focused on the influence of the phosphors on the PSD quality and light yield. The effect of only one phosphor with a large Stokes shift was investigated, as well as the effect of a secondary phosphor as a wavelength shifter within the used solvents, again prepared under a nitrogen atmosphere and ambient environment. The used solvents can be divided into three categories: a) classical (toluene, xylene, styrene), b) naphthalene derivates (Diisopropylnaphthalene (mixture of isomers), and 1-Methylnaphthalene) and c) Linear alkylbenzenes (Diethylbenzene, Dodecylbenzene, and Propylbenzene). Five phosphor groups were tested using different phosphors or mixtures of phosphors namely para terphenyl and 1,4-bis(5-phenyloxazol-2-yl) benzene (pTP+POPOP), 2,5-Diphenyloxazole and p-Bis(o-methylstyryl) benzene (PPO+MSB), 1-Phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline (PYR), 2,5-Bis(5-tert-butyl-benzoxazol-2-yl)thiophene (THIO), and 2-(1-naftyl)-5-fenyloxazol (NPO). The first one is the oldest one with very good PSD ability, the second one is standard in PSD scintillators. The rest of them are experimental phosphores with large Stokes shifts without the need for a second phosphor (wavelength shifter).
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (5) , 1091-1099
The Influence of Oxygen on Pulse Shape Discrimination at Various Solvents and Phosphors
In this work, the issue of oxygen quenching on the PSD ability/quality of liquid scintillation cocktails is addressed throughout the investigation of the effect of different solvents on PSD quality and light yield using different concentrations of the phosphor PPO+MSB. Two different atmospheric conditions were in the preparation of the samples, one consisted of air at standard temperature and pressure (STP) and the other was nitrogen. The second part of the work is focused on the influence of the phosphors on the PSD quality and light yield. The effect of only one phosphor with a large Stokes shift was investigated, as well as the effect of a secondary phosphor as a wavelength shifter within the used solvents, again prepared under a nitrogen atmosphere and ambient environment. The used solvents can be divided into three categories: a) classical (toluene, xylene, styrene), b) naphthalene derivates (Diisopropylnaphthalene (mixture of isomers), and 1-Methylnaphthalene) and c) Linear alkylbenzenes (Diethylbenzene, Dodecylbenzene, and Propylbenzene). Five phosphor groups were tested using different phosphors or mixtures of phosphors namely para terphenyl and 1,4-bis(5-phenyloxazol-2-yl) benzene (pTP+POPOP), 2,5-Diphenyloxazole and p-Bis(o-methylstyryl) benzene (PPO+MSB), 1-Phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline (PYR), 2,5-Bis(5-tert-butyl-benzoxazol-2-yl)thiophene (THIO), and 2-(1-naftyl)-5-fenyloxazol (NPO). The first one is the oldest one with very good PSD ability, the second one is standard in PSD scintillators. The rest of them are experimental phosphores with large Stokes shifts without the need for a second phosphor (wavelength shifter).
- Open Access
- 1 January 2024
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 39 (2) , 138-145
Liquid-liquid extraction of Am(III), Pu(IV), and U(VI) using malonamide and tributyl phosphate in room temperature ionic liquids as diluent
The extraction behavior of americium, plutonium, and uranium from nitric or hydrochloric acidic medium by a solution of malonamide or tributyl phosphate in trioctylmethylammonium chloride (Aliquat 336) or trihexyl(tetradecyl)phosphonium chloride (Cyphos 101) ionic liquids were studied. The extraction percentage of these actinides was measured as a function of a concentration of nitric or hydrochloric acid and a set combination of a room temperature ionic liquid and an extractant. The pure room temperature ionic liquids could extract the plutonium and uranium to various degrees, with the combinations with extractants affecting the extraction percentages further. The 100 % extraction efficiency of plutonium was achieved across all concentrations of HCl with the combinations of Cyphos 101 and malonamide. 100% extraction efficiency of uranium was achieved by Cyphos 101 and malonamide from distilled water. Americium was not extracted by any combination under any conditions.
- 1 January 2024
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 39 (2) , 138-145
Open AccessLiquid-liquid extraction of Am(III), Pu(IV), and U(VI) using malonamide and tributyl phosphate in room temperature ionic liquids as diluent
The extraction behavior of americium, plutonium, and uranium from nitric or hydrochloric acidic medium by a solution of malonamide or tributyl phosphate in trioctylmethylammonium chloride (Aliquat 336) or trihexyl(tetradecyl)phosphonium chloride (Cyphos 101) ionic liquids were studied. The extraction percentage of these actinides was measured as a function of a concentration of nitric or hydrochloric acid and a set combination of a room temperature ionic liquid and an extractant. The pure room temperature ionic liquids could extract the plutonium and uranium to various degrees, with the combinations with extractants affecting the extraction percentages further. The 100 % extraction efficiency of plutonium was achieved across all concentrations of HCl with the combinations of Cyphos 101 and malonamide. 100% extraction efficiency of uranium was achieved by Cyphos 101 and malonamide from distilled water. Americium was not extracted by any combination under any conditions.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1342-1348
Temperature Dependences and Gamma Radiation Stability of Liquid Scintillation Cocktails for n–γ Discrimination
To correctly use different devices, including liquid scintillators, operating parameters have to be known and be at disposal. Among many others, the temperature influence and radiation hardness play an important role. The liquid organic scintillators namely EJ-301, EJ-309 (both Eljen Technology), and new custom-made cocktails based on 1-Phenyl-3-(2,4,6-trimethylphenyl)-2-pyrazoline and 2,5-Bis(5-tert-butyl-benzoxazol-2-yl)thiophene fluors have been tested for temperature stability and radiation resistance. The temperature dependence, in terms of neutron-gamma discrimination, was found to be very weak with the temperature coefficient in order of 10 -4 MeVee/°C. As far as the gamma radiation resistance of scintillators goes, THIO proved to give consistent results almost independently of the absorbed dose. The EJ-301 exhibited the second-best result. EJ-309 was mostly comparable with PYR except for isomerization, which was observed at an absorbed dose from gamma irradiation greater than 10 kGy. In addition, the color change of borosilicate glass, serving as the casing, was noticed causing decreasing in light yield.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1342-1348
Temperature Dependences and Gamma Radiation Stability of Liquid Scintillation Cocktails for n–γ Discrimination
To correctly use different devices, including liquid scintillators, operating parameters have to be known and be at disposal. Among many others, the temperature influence and radiation hardness play an important role. The liquid organic scintillators namely EJ-301, EJ-309 (both Eljen Technology), and new custom-made cocktails based on 1-Phenyl-3-(2,4,6-trimethylphenyl)-2-pyrazoline and 2,5-Bis(5-tert-butyl-benzoxazol-2-yl)thiophene fluors have been tested for temperature stability and radiation resistance. The temperature dependence, in terms of neutron-gamma discrimination, was found to be very weak with the temperature coefficient in order of 10 -4 MeVee/°C. As far as the gamma radiation resistance of scintillators goes, THIO proved to give consistent results almost independently of the absorbed dose. The EJ-301 exhibited the second-best result. EJ-309 was mostly comparable with PYR except for isomerization, which was observed at an absorbed dose from gamma irradiation greater than 10 kGy. In addition, the color change of borosilicate glass, serving as the casing, was noticed causing decreasing in light yield.
- 10 November 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (5) , 1427-1433
The use of a citric–oxalic–sulfate as a new electrodeposition solution
- 10 November 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (5) , 1427-1433
The use of a citric–oxalic–sulfate as a new electrodeposition solution
- 21 September 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 190, 110475
The use of plastic scintillation microspheres in flow scintillation analysis
- 21 September 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 190, 110475
The use of plastic scintillation microspheres in flow scintillation analysis
- 6 September 2022
- Published by Elsevier in Journal of Luminescence
- Vol. 252
Photo-induced preparation of Ce-doped terbium aluminum garnet and its luminescent properties
- 6 September 2022
- Published by Elsevier in Journal of Luminescence
- Vol. 252
Photo-induced preparation of Ce-doped terbium aluminum garnet and its luminescent properties
- 13 June 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (8) , 3231-3240
Optimization of composition of water accepting scintillation cocktail
- 13 June 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (8) , 3231-3240
Optimization of composition of water accepting scintillation cocktail
- Open Access
- 12 May 2022
- Published by MDPI AG in Quantum Beam Science
- Vol. 6 (2) , 18
Response to Mono-Energetic Neutrons and Light Output Function for Liquid Organic Scintillators PYR5/DIPN and THIO5/DIPN
Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component scintillators to mono-energetic neutron radiation and to determine their light output function, which is necessary for proper neutron energy spectra determination. Both scintillators are composed of the solvent di-iso-propyl-naphthalene (DIPN) mixed isomers. The first scintillator, labeled PYR5/DIPN, contains the luminophore 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline with a concentration of 5 g/L. The second scintillator labeled THIO5/DIPN contains the luminophore 2,5-bis(5-tert-butyl-benzoxazol-2-yl)thiophene also with a concentration of 5 g/L. The responses to neutron energies of 1.5 MeV, 2.5 MeV, and 19 MeV are measured at PTB in Braunschweig. The responses to neutron energies of 2.45 MeV and 14 MeV were measured at CTU in Prague using DD and DT reactions. The responses to a silicon filtered beam were measured at Research Centre Řež. The measurements were processed using a two-parameter spectrometric system NGA-01 to discriminate neutrons from gamma rays. The obtained responses are dominated by recoil protons from elastic collisions of neutrons with hydrogen atoms. The edge of the response of recoil protons gives information about the light output of neutrons, compared to gamma rays for the same radiation energy. The light output function for protons in the PYR5/DIPN scintillator is . The light output function for protons in the THIO5/DIPN scintillator is . The light output functions well resemble the standard shape, and they are quite similar to each other. That suggests a weak influence of the luminophore on the light output function. The light output functions are ready to be incorporated to the response matrix for the neutron energy spectra determination.- 12 May 2022
- Published by MDPI AG in Quantum Beam Science
- Vol. 6 (2) , 18
Open AccessResponse to Mono-Energetic Neutrons and Light Output Function for Liquid Organic Scintillators PYR5/DIPN and THIO5/DIPN
Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component scintillators to mono-energetic neutron radiation and to determine their light output function, which is necessary for proper neutron energy spectra determination. Both scintillators are composed of the solvent di-iso-propyl-naphthalene (DIPN) mixed isomers. The first scintillator, labeled PYR5/DIPN, contains the luminophore 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline with a concentration of 5 g/L. The second scintillator labeled THIO5/DIPN contains the luminophore 2,5-bis(5-tert-butyl-benzoxazol-2-yl)thiophene also with a concentration of 5 g/L. The responses to neutron energies of 1.5 MeV, 2.5 MeV, and 19 MeV are measured at PTB in Braunschweig. The responses to neutron energies of 2.45 MeV and 14 MeV were measured at CTU in Prague using DD and DT reactions. The responses to a silicon filtered beam were measured at Research Centre Řež. The measurements were processed using a two-parameter spectrometric system NGA-01 to discriminate neutrons from gamma rays. The obtained responses are dominated by recoil protons from elastic collisions of neutrons with hydrogen atoms. The edge of the response of recoil protons gives information about the light output of neutrons, compared to gamma rays for the same radiation energy. The light output function for protons in the PYR5/DIPN scintillator is . The light output function for protons in the THIO5/DIPN scintillator is . The light output functions well resemble the standard shape, and they are quite similar to each other. That suggests a weak influence of the luminophore on the light output function. The light output functions are ready to be incorporated to the response matrix for the neutron energy spectra determination. - Open Access
- 19 November 2021
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 253, 11004
The effect of the aging of liquid organic scintillators used for gamma-neutron separation
Since the beginning of using liquid scintillators for gamma-neutron separation, there have been many articles dealing with long-term degradation especially due to oxygen presented during scintillator encapsulation. The effect of aging of liquid organic scintillators namely EJ301, EJ309 (both Eljen Technology), and new custom-made cocktails based on 1-Phenyl-3-(2,4,6-trimethylphenyl)-2-pyrazoline and 2,5-Bis(5-tert-butyl-benzoxazol-2-yl)thiophene fluors were investigated for more than half a year. The research was focused on the Compton edge shifting of gamma particles since the position is proportional to the light yield of the selected scintillator. Furthermore, the gamma-neutron separation was observed and quantified using FOM (Figure Of Merit) for samples prepared and filled under normal and nitrogen atmosphere during the mentioned period. All stated parameters of liquid scintillator NE213 manufactured by Nuclear Enterprises Limited opened more than three decades ago were measured and used for comparison.
- 19 November 2021
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 253, 11004
Open AccessThe effect of the aging of liquid organic scintillators used for gamma-neutron separation
Since the beginning of using liquid scintillators for gamma-neutron separation, there have been many articles dealing with long-term degradation especially due to oxygen presented during scintillator encapsulation. The effect of aging of liquid organic scintillators namely EJ301, EJ309 (both Eljen Technology), and new custom-made cocktails based on 1-Phenyl-3-(2,4,6-trimethylphenyl)-2-pyrazoline and 2,5-Bis(5-tert-butyl-benzoxazol-2-yl)thiophene fluors were investigated for more than half a year. The research was focused on the Compton edge shifting of gamma particles since the position is proportional to the light yield of the selected scintillator. Furthermore, the gamma-neutron separation was observed and quantified using FOM (Figure Of Merit) for samples prepared and filled under normal and nitrogen atmosphere during the mentioned period. All stated parameters of liquid scintillator NE213 manufactured by Nuclear Enterprises Limited opened more than three decades ago were measured and used for comparison.