Abdul Quddus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdul Quddus has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Anwar Ul-Hamid
Core Research Facilities, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia
4 shared publications - Huseyin Saricimen
Department of Industrial Engineering, Yalova University, Yalova, Turkey
2 shared publications Luai M. Al-Hadhrami
Research Institute, King Fahd University of Petroleum & Minerals , KFUPM Box 1524, Dhahran 31261, Saudi , Arabia
2 shared publicationsDhawi A. Al-Otaibi
Consulting Service Department , Saudi Aramco , Dhahran , Saudi Arabia
1 shared publicationH. Saricimen
King Fahd University of Petroleum and Minerals
1 shared publicationHatim Dafalla
King Fahd University of Petroleum & Minerals, Saudi Arabia
1 shared publication
Latest Publications
- 5 June 2017
- Published by Emerald Publishing in Anti-Corrosion Methods and Materials
- Vol. 64 (4) , 424-431
Failure analysis of coated galvanized steel panels
Purpose: The purpose of this paper was to determine the mode and cause of failure of polyester-coated galvanized corrugated steel sheets that exhibited degradation of the coating after seven months into service. Design/methodology/approach: Visual inspection and light microscopy revealed the extent of damage exhibited by the panels. Standard metallographic techniques were used to prepare samples obtained from both unused and failed sections. Light microscopy, scanning electron microscopy combined with energy dispersive x-ray spectroscopy and x-ray diffraction techniques were used to study the surface morphology, microstructural features, elemental composition and structure of the samples. Findings: The failure occurred in the form of delamination and blistering of coated layer. Presence of solar radiation, humidity and water retention resulted in loss of adhesion, leading to coating delamination and flaking especially at the top surface. The coating at the bottom surface of the panels showed evidence of blistering caused by water vapor differential that existed between the environment and the coating because of prolonged (four months) wet conditions that existed at the manufacturer’s site during storage. Practical implications: It is recommended that the coated panels are stored in covered area where direct exposure to atmospheric conditions can be prevented. If open storage is unavoidable, then the use of tarpaulin or plastic sheet as covering and vapor-phase inhibitors was recommended. Originality/value: This paper provides an account of failure analysis of metal sheet panels. It identifies the mode and cause of failure and also provides recommendations to avoid such occurrences in the future. The information contained in this paper is useful for plant engineers and project managers working in the metal sheet industry.
- 5 June 2017
- Published by Emerald Publishing in Anti-Corrosion Methods and Materials
- Vol. 64 (4) , 424-431
Failure analysis of coated galvanized steel panels
Purpose: The purpose of this paper was to determine the mode and cause of failure of polyester-coated galvanized corrugated steel sheets that exhibited degradation of the coating after seven months into service. Design/methodology/approach: Visual inspection and light microscopy revealed the extent of damage exhibited by the panels. Standard metallographic techniques were used to prepare samples obtained from both unused and failed sections. Light microscopy, scanning electron microscopy combined with energy dispersive x-ray spectroscopy and x-ray diffraction techniques were used to study the surface morphology, microstructural features, elemental composition and structure of the samples. Findings: The failure occurred in the form of delamination and blistering of coated layer. Presence of solar radiation, humidity and water retention resulted in loss of adhesion, leading to coating delamination and flaking especially at the top surface. The coating at the bottom surface of the panels showed evidence of blistering caused by water vapor differential that existed between the environment and the coating because of prolonged (four months) wet conditions that existed at the manufacturer’s site during storage. Practical implications: It is recommended that the coated panels are stored in covered area where direct exposure to atmospheric conditions can be prevented. If open storage is unavoidable, then the use of tarpaulin or plastic sheet as covering and vapor-phase inhibitors was recommended. Originality/value: This paper provides an account of failure analysis of metal sheet panels. It identifies the mode and cause of failure and also provides recommendations to avoid such occurrences in the future. The information contained in this paper is useful for plant engineers and project managers working in the metal sheet industry.
- 12 September 2015
- Published by Pleiades Publishing Ltd in Protection of Metals and Physical Chemistry of Surfaces
- Vol. 51 (5) , 803-811
Effect of calcination on nanoscale zirconia produced by high temperature hydrolysis
Acidic and ammoniacal zirconium chloride solutions were subjected to high temperature hydrolysis (HTH) at temperatures between 110 and 150°C. The precipitates obtained from ammoniacal solutions were i
- 12 September 2015
- Published by Pleiades Publishing Ltd in Protection of Metals and Physical Chemistry of Surfaces
- Vol. 51 (5) , 803-811
Effect of calcination on nanoscale zirconia produced by high temperature hydrolysis
Acidic and ammoniacal zirconium chloride solutions were subjected to high temperature hydrolysis (HTH) at temperatures between 110 and 150°C. The precipitates obtained from ammoniacal solutions were i
- Open Access
- 1 February 2015
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 18 (1) , 20-26
Corrosion Behavior of Coarse- and Fine-Grain Ni Coatings Incorporating NaH2PO4.H2O Inhibitor Treated Substrates
- 1 February 2015
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 18 (1) , 20-26
Open AccessCorrosion Behavior of Coarse- and Fine-Grain Ni Coatings Incorporating NaH2PO4.H2O Inhibitor Treated Substrates
- 17 May 2014
- Published by Pleiades Publishing Ltd in Protection of Metals and Physical Chemistry of Surfaces
- Vol. 50 (3) , 391-399
Hot corrosion behavior of plasma and HVOF sprayed Co- and Ni-based coatings at 900°C
High temperature Co- and Ni-based metallic coatings were applied on samples of 310 stainless steel using plasma spray and high velocity oxy fuel (HVOF) methods. The samples were sprayed with Na2SO4, V2O5 and NaCl salt solutions and exposed in air at 900°C to cyclic conditions with an aim to simulate an environment typically encountered in oil refinery operation. Extent of hot corrosion damage was assessed using gravimetric measurements while microstructure of the coatings was examined using scanning electron microscopy coupled with energy dispersive X-ray spectroscopy. X-ray diffraction was used to determine phase constitution. The aim of this study was to evaluate and compare the performance of specific coatings in hot corrosive environments. Experimental results indicate that the presence of V2O5 and NaCl serves to enhance hot corrosion while Co-based coatings perform better than Ni-based coating.
- 17 May 2014
- Published by Pleiades Publishing Ltd in Protection of Metals and Physical Chemistry of Surfaces
- Vol. 50 (3) , 391-399
Hot corrosion behavior of plasma and HVOF sprayed Co- and Ni-based coatings at 900°C
High temperature Co- and Ni-based metallic coatings were applied on samples of 310 stainless steel using plasma spray and high velocity oxy fuel (HVOF) methods. The samples were sprayed with Na2SO4, V2O5 and NaCl salt solutions and exposed in air at 900°C to cyclic conditions with an aim to simulate an environment typically encountered in oil refinery operation. Extent of hot corrosion damage was assessed using gravimetric measurements while microstructure of the coatings was examined using scanning electron microscopy coupled with energy dispersive X-ray spectroscopy. X-ray diffraction was used to determine phase constitution. The aim of this study was to evaluate and compare the performance of specific coatings in hot corrosive environments. Experimental results indicate that the presence of V2O5 and NaCl serves to enhance hot corrosion while Co-based coatings perform better than Ni-based coating.
- Open Access
- 1 March 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (13-15) , 2521-2528
Calcium sulfate scale deposition on coated carbon steel and titanium
Scaling/fouling is a thermal barrier in heat transfer equipment which badly impedes heat-exchanger efficiency and renders production losses. The application of thermally conductive polymer coatings on low-cost materials is common to cope with the problem of fouling and corrosion, and is also a cost-effective alternative for the replacement of expensive materials in petroleum industry. Calcium sulfate (CaSO4) is one of the commonly found scales in Arabian Gulf region. An experimental study was undertaken using rotating cylinder electrode equipment to assess the performance of a polymer (SAKAPHEN Si57E) coating applied on carbon steel with regard to CaSO4 scaling on coated steel and titanium metal. The scale was obtained at 60°C, atmospheric pressure and at various rotational speeds ranging from 100 to 2,000 rpm on both the materials. The results of the study showed that the growth of calcium sulfate scale on bare titanium metal increased significantly while it remained almost invariant on the coated carbon steel surface, with increasing rotational speeds. The anomalous behavior of coated steel samples was attributed to the competing effect between scale deposition and scale removal process due to the fluid flow and to the coating’s antifouling characteristics, which resulted in less scale adhesion on coated steel compared to bare titanium metal surface. In addition, the field performance and economic appraisal of the selected coating are presented, as well.
- 1 March 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (13-15) , 2521-2528
Open AccessCalcium sulfate scale deposition on coated carbon steel and titanium
Scaling/fouling is a thermal barrier in heat transfer equipment which badly impedes heat-exchanger efficiency and renders production losses. The application of thermally conductive polymer coatings on low-cost materials is common to cope with the problem of fouling and corrosion, and is also a cost-effective alternative for the replacement of expensive materials in petroleum industry. Calcium sulfate (CaSO4) is one of the commonly found scales in Arabian Gulf region. An experimental study was undertaken using rotating cylinder electrode equipment to assess the performance of a polymer (SAKAPHEN Si57E) coating applied on carbon steel with regard to CaSO4 scaling on coated steel and titanium metal. The scale was obtained at 60°C, atmospheric pressure and at various rotational speeds ranging from 100 to 2,000 rpm on both the materials. The results of the study showed that the growth of calcium sulfate scale on bare titanium metal increased significantly while it remained almost invariant on the coated carbon steel surface, with increasing rotational speeds. The anomalous behavior of coated steel samples was attributed to the competing effect between scale deposition and scale removal process due to the fluid flow and to the coating’s antifouling characteristics, which resulted in less scale adhesion on coated steel compared to bare titanium metal surface. In addition, the field performance and economic appraisal of the selected coating are presented, as well.
- Open Access
- 17 December 2012
- Published by Elsevier in Desalination and Water Treatment
- Vol. 50 (1-3) , 285-293
Impact of solution hydrodynamics on the deposition of CaSO4 on brass
An investigation was conducted to study the impact of solution hydrodynamics on the deposition of calcium sulfate scale on commercial brass by using a rotating cylinder electrode system at various pre-set rotational speeds, at 60 and 70°C on 120 and 600 grits polished cylindrical specimens. The effects of temperature, surface roughness, and flow conditions on the deposition of calcium sulfate scale on brass are presented. The results indicate the influence of solution hydrodynamics on the rate of calcium sulfate scale deposition on brass specimens by delineating the competing effect between the scale deposition and scale removal process that is occurring simultaneously under the fluid flow conditions generated in the study. The morphology of deposited crystals was obtained from scanning electron microscope (SEM) micrographs and composition was determined with energy dispersive X-ray spectrometer (EDS) method. The SEM analysis revealed prismatic needle- and rod-like crystals growth structure at nucleation sites branching out randomly over the substrate. The secondary growth on the already existing primary crystals of CaSO4 was also noticed. The EDS analysis confirmed the composition of crystals comprising of Ca, S, and O as expected because of the purity of chemicals used.
- 17 December 2012
- Published by Elsevier in Desalination and Water Treatment
- Vol. 50 (1-3) , 285-293
Open AccessImpact of solution hydrodynamics on the deposition of CaSO4 on brass
An investigation was conducted to study the impact of solution hydrodynamics on the deposition of calcium sulfate scale on commercial brass by using a rotating cylinder electrode system at various pre-set rotational speeds, at 60 and 70°C on 120 and 600 grits polished cylindrical specimens. The effects of temperature, surface roughness, and flow conditions on the deposition of calcium sulfate scale on brass are presented. The results indicate the influence of solution hydrodynamics on the rate of calcium sulfate scale deposition on brass specimens by delineating the competing effect between the scale deposition and scale removal process that is occurring simultaneously under the fluid flow conditions generated in the study. The morphology of deposited crystals was obtained from scanning electron microscope (SEM) micrographs and composition was determined with energy dispersive X-ray spectrometer (EDS) method. The SEM analysis revealed prismatic needle- and rod-like crystals growth structure at nucleation sites branching out randomly over the substrate. The secondary growth on the already existing primary crystals of CaSO4 was also noticed. The EDS analysis confirmed the composition of crystals comprising of Ca, S, and O as expected because of the purity of chemicals used.
- 1 January 2011
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 25 (1) , 112-118
Influence of Solution Hydrodynamics on the Deposition of CaSO4 Scale on Aluminum
- 1 January 2011
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 25 (1) , 112-118
Influence of Solution Hydrodynamics on the Deposition of CaSO4 Scale on Aluminum