Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Janez Trontelj has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Position Sensing with a Compact 0.1 THz Amplitude Modulated Source

    by Tadej Krmac, Andrej Švigelj, Janez Trontelj

    Position determination is an important manufacturing process in many modern industries. The objective of this paper is to present an affordable measurement system that can replace optical position measurement with a laser beam in an opaque environment that prevents the laser beam from penetrating through the fog of gases or other materials that are opaque to optical light. THz waves are a good example of replacing a laser beam, as shown in this article. It is known that THz rays can penetrate fabrics, wood, Styrofoam, etc. The triangulation method using an amplitude modulated THz source proved to be a cost-effective solution for position determination in opaque environments.

  • Open Access

    Titanium-Based Microbolometers: Control of Spatial Profile of Terahertz Emission in Weak Power Sources

    by Linas Minkevičius, Liang Qi, Agnieszka Siemion, Domas Jokubauskis, Aleksander Sešek, Andrej Švigelj, Janez Trontelj, Dalius Seliuta, Irmantas Kašalynas, Gintaras Valušis

    Terahertz (THz) imaging and spectroscopy set-ups require fine optical alignment or precise control of spatial mode profile. We demonstrate universal, convenient and easy-to-use imaging—resonant and broadband antenna coupled ultrasensitive titanium-based—dedicated to accurately adjust and control spatial mode profiles without additional focusing optical components of weak power THz sources. Versatile operation of the devices is shown using different kinds of THz—electronic multiplier sources, optical THz mixer-based frequency domain and femtosecond optoelectronic THz time-domain spectrometers as well as optically pumped molecular THz laser. Features of the microbolometers within 0.15–0.6 THz range are exposed and discussed, their ability to detect spatial mode profiles beyond the antennas resonances, up to 2.52 THz, are explored. Polarization-sensitive mode control possibilities are examined in details. The suitability of the resonant antenna-coupled microbolometers to resolve low-absorbing objects at 0.3 THz is revealed via direct, dark field and phase contrast imaging techniques as well.


  • Mobile wireless monitoring system for prehospital emergency care

    by Natasa Koceska, Radko Komadina, Monika Simjanoska, Bojana Koteska, Andrej Strahovnik, Anton Jošt, Rok Maček, Ana Madevska-Bogdanova, Vladimir Trajkovik, Jurij Franc Tasič, et al.

    Latest achievement technologies allow engineers to develop medical systems that medical doctors in the health care system could not imagine years ago. The development of signal theory, intelligent systems, biophysics and extensive collaboration between science and technology researchers and medical professionals, open up the potential for preventive, real-time monitoring of patients. With the recent developments of new methods in medicine, it is also possible to predict the trends of the disease development as well the systemic support in diagnose setting. Within the framework of the needs to track the patient health parameters in the hospital environment or in the case of road accidents, the researchers had to integrate the knowledge and experiences of medical specialists in emergency medicine who have participated in the development of a mobile wireless monitoring system designed for real-time monitoring of victim vital parameters. Emergency medicine responders are first point of care for trauma victim providing prehospital care, including triage and treatment at the scene of incident and transport from the scene to the hospital. Continuous monitoring of life functions allows immediate detection of a deterioration in health status and helps out in carrying out principle of continuous e-triage. In this study, a mobile wireless monitoring system for measuring and recording the vital parameters of the patient was presented and evaluated. Based on the measured values, the system is able to make triage and assign treatment priority for the patient. The system also provides the opportunity to take a picture of the injury, mark the injured body parts, calculate Glasgow Coma Score, or insert/record the medication given to the patient. Evaluation of the system was made using the Technology Acceptance Model (TAM). In particular we measured: perceived usefulness, perceived ease of use, attitude, intention to use, patient status and environmental status.


  • Open Access

    A THz Receiver with Novel Features and Functionality

    by Aleksander Sešek, Damjan Berčan, Miha Gradišek, Andrej Švigelj, Janez Trontelj

    The presented THz receiver is based on an antenna coupled titanium micro-bolometer. A new geometrical design improves the robustness and extends the lifetime of the sensor. A study of sensor lifetime using different biasing currents is presented. The lifetime was verified by several tests and over 1000 operating hours. A new micro-bolometer sensitivity measurement algorithm is presented in the paper and measurement results using the proposed algorithm are shown. The new algorithm was developed to be suitable for ATM production testing. In the paper, a novel feature called “sensitivity boosting” is described, together with its influence on sensitivity and lifetime.


  • Open Access

    Spectroscopic Terahertz Imaging at Room Temperature Employing Microbolometer Terahertz Sensors and Its Application to the Study of Carcinoma Tissues

    by Irmantas Kašalynas, Rimvydas Venckevičius, Linas Minkevičius, Aleksander Sešek, Faustino Wahaia, Vincas Tamošiūnas, Bogdan Voisiat, Dalius Seliuta, Gintaras Valušis, Andrej Švigelj, et al.

    A terahertz (THz) imaging system based on narrow band microbolometer sensors (NBMS) and a novel diffractive lens was developed for spectroscopic microscopy applications. The frequency response characteristics of the THz antenna-coupled NBMS were determined employing Fourier transform spectroscopy. The NBMS was found to be a very sensitive frequency selective sensor which was used to develop a compact all-electronic system for multispectral THz measurements. This system was successfully applied for principal components analysis of optically opaque packed samples. A thin diffractive lens with a numerical aperture of 0.62 was proposed for the reduction of system dimensions. The THz imaging system enhanced with novel optics was used to image for the first time non-neoplastic and neoplastic human colon tissues with close to wavelength-limited spatial resolution at 584 GHz frequency. The results demonstrated the new potential of compact RT THz imaging systems in the fields of spectroscopic analysis of materials and medical diagnostics.


  • Open Access

    A Differential Monolithically Integrated Inductive Linear Displacement Measurement Microsystem

    by Matija Podhraški, Janez Trontelj

    An inductive linear displacement measurement microsystem realized as a monolithic Application-Specific Integrated Circuit (ASIC) is presented. The system comprises integrated microtransformers as sensing elements, and analog front-end electronics for signal processing and demodulation, both jointly fabricated in a conventional commercially available four-metal 350-nm CMOS process. The key novelty of the presented system is its full integration, straightforward fabrication, and ease of application, requiring no external light or magnetic field source. Such systems therefore have the possibility of substituting certain conventional position encoder types. The microtransformers are excited by an AC signal in MHz range. The displacement information is modulated into the AC signal by a metal grating scale placed over the microsystem, employing a differential measurement principle. Homodyne mixing is used for the demodulation of the scale displacement information, returned by the ASIC as a DC signal in two quadrature channels allowing the determination of linear position of the target scale. The microsystem design, simulations, and characterization are presented. Various system operating conditions such as frequency, phase, target scale material and distance have been experimentally evaluated. The best results have been achieved at 4 MHz, demonstrating a linear resolution of 20 µm with steel and copper scale, having respective sensitivities of 0.71 V/mm and 0.99 V/mm.


  • Open Access

    Humidity Sensors Printed on Recycled Paper and Cardboard

    by Matija Mraović, Tadeja Muck, Matej Pivar, Janez Trontelj, Anton Pleteršek

    Research, design, fabrication and results of various screen printed capacitive humidity sensors is presented in this paper. Two types of capacitive humidity sensors have been designed and fabricated via screen printing on recycled paper and cardboard, obtained from the regional paper and cardboard industry. As printing ink, commercially available silver nanoparticle-based conductive ink was used. A considerable amount of work has been devoted to the humidity measurement methods using paper as a dielectric material. Performances of different structures have been tested in a humidity chamber. Relative humidity in the chamber was varied in the range of 35%–80% relative humidity (RH) at a constant temperature of 23 °C. Parameters of interest were capacitance and conductance of each sensor material, as well as long term behaviour. Process reversibility has also been considered. The results obtained show a mainly logarithmic response of the paper sensors, with the only exception being cardboard-based sensors. Recycled paper-based sensors exhibit a change in value of three orders of magnitude, whereas cardboard-based sensors have a change in value of few 10s over the entire scope of relative humidity range (RH 35%–90%). Two different types of capacitor sensors have been investigated: lateral (comb) type sensors and modified, perforated flat plate type sensors. The objective of the present work was to identify the most important factors affecting the material performances with humidity, and to contribute to the development of a sensor system supported with a Radio Frequency Identification (RFID) chip directly on the material, for use in smart packaging applications. Therefore, the authors built a passive and a battery-supported wireless module based on SL900A smart sensory tag’s IC to achieve UHF-RFID functionality with data logging capability.


  • Open Access

    THz technology for vision systems

    by J. Trontelj, A. Sesek, A. Svigelj

    D.o.o, Šempeter pri Gorici, Slovenija KW nema KR nema The THz radiation brings new technology challenges and new opportunities to overcome some of the current application obstacles. In the paper a portable THz system is presented operating at room temperature. The presented solution is robust and inexpensive, convenient for many applications. The THz sensor fabricated at the Faculty of Electrical Engineering in the Laboratory for Microelectronics is currently one of the best sensors in its frequency operating range. It reaches sensitivity up to 1000V/W and NEP down to 5pW/√Hz in vacuum. With the proposed system solution variety of application can be covered. Some imaging results captured with the proposed system at different stand-off distances are shown in the paper.


  • Monitoring, Control and Diagnostics using RFID Infrastructure

    by Anton Pleteršek, Miha Sok, Janez Trontelj

    This work demonstrates the developed application for disinfection control by the sensing of chemical agents. The objective was to develop an Automatic Disinfectant Tracker (ADT) that would verify the disinfection of the hands of nurses, doctors, staff, patients, and visitors in hospitals within a required time frame. We have successfully investigated the development of hand disinfection control mechanisms and demonstrated two approaches, both based on the wireless Ultra-High-Frequency-based Radio-Frequency Identification (UHF-RFID) technology. The 100 % efficacy of detecting propanol and ethanol concentration was achieved by using the static disinfectant control (SDC-ADT) method. The time domain response provides an accurate determination of their performance in practice simply by measuring the applied disinfectant concentration and the duration of application. The present paper resulted from the measurements of a capacitive chemical sensor fabricated in the Laboratory for Microelectronics, (LMFE) and on measurements, based on a commercially available resistive type of sensor. A graphic user interface (IDS-GUI) is designed to successfully set the logger parameters and display the results.