Sebastian Vogt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sebastian Vogt has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Frank Sauer
Imaging and Visualization Dept., Siemens Corporate, Research Princeton, NJ, USA
4 shared publications - Ali Khamene
Imaging and Visualization Department, Siemens Corporate Research, Inc., 755 College Road East, Princeton, NJ 08540, USA
3 shared publications - Ali Uneri
Johns Hopkins University
2 shared publications - Gerhard Kleinszig
Siemens Healthcare XP, Erlangen, Germany
2 shared publications - Jeffrey H. Siewerdsen
Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, USA
2 shared publications - Tharindu De Silva
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
2 shared publications
Latest Publications
- 11 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 36 (10) , 1997-2009
Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy
For image-guided procedures, the imaging task is often tied to the registration of intraoperative and preoperative images to a common coordinate system. While the accuracy of this registration is a vital factor in system performance, there is a relatively little work that relates registration accuracy to image quality factors, such as dose, noise, and spatial resolution. To create a theoretical model for such a relationship, we present a Fisher information approach to analyze registration performance in explicit dependence on the underlying image quality factors of image noise, spatial resolution, and signal power spectrum. The model yields analysis of the Cramer-Rao lower bound (CRLB), in registration accuracy as a function of factors governing image quality. Experiments were performed in simulation of computed tomography low-contrast soft tissue images and high-contrast bone (head and neck) images to compare the measured accuracy [root mean squared error (RMSE) of the estimated transformations] with the theoretical lower bound. Analysis of the CRLB reveals that registration performance is closely related to the signal-to-noise ratio of the cross-correlation space. While the lower bound is optimistic, it exhibits consistent trends with experimental findings and yields a method for comparing the performance of various registration methods and similarity metrics. Further analysis validated a method for determining optimal post-processing (image filtering) for registration. Two figures of merit (CRLB and RMSE) are presented that unify models of image quality with registration performance, providing an important guide to optimizing intraoperative imaging with respect to the task of registration.
- 11 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 36 (10) , 1997-2009
Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy
For image-guided procedures, the imaging task is often tied to the registration of intraoperative and preoperative images to a common coordinate system. While the accuracy of this registration is a vital factor in system performance, there is a relatively little work that relates registration accuracy to image quality factors, such as dose, noise, and spatial resolution. To create a theoretical model for such a relationship, we present a Fisher information approach to analyze registration performance in explicit dependence on the underlying image quality factors of image noise, spatial resolution, and signal power spectrum. The model yields analysis of the Cramer-Rao lower bound (CRLB), in registration accuracy as a function of factors governing image quality. Experiments were performed in simulation of computed tomography low-contrast soft tissue images and high-contrast bone (head and neck) images to compare the measured accuracy [root mean squared error (RMSE) of the estimated transformations] with the theoretical lower bound. Analysis of the CRLB reveals that registration performance is closely related to the signal-to-noise ratio of the cross-correlation space. While the lower bound is optimistic, it exhibits consistent trends with experimental findings and yields a method for comparing the performance of various registration methods and similarity metrics. Further analysis validated a method for determining optimal post-processing (image filtering) for registration. Two figures of merit (CRLB and RMSE) are presented that unify models of image quality with registration performance, providing an important guide to optimizing intraoperative imaging with respect to the task of registration.
- 2 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (11) , 2413-2424
MIND Demons: Symmetric Diffeomorphic Deformable Registration of MR and CT for Image-Guided Spine Surgery
Intraoperative localization of target anatomy and critical structures defined in preoperative MR/CT images can be achieved through the use of multimodality deformable registration. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality-independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. The method, called MIND Demons, finds a deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the integrated velocity fields, a modality-insensitive similarity function suitable to multimodality images, and smoothness on the diffeomorphisms themselves. Direct optimization without relying on the exponential map and stationary velocity field approximation used in conventional diffeomorphic Demons is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, normalized MI (NMI) Demons, and MIND with a diffusion-based registration method (MIND-elastic). The method yielded sub-voxel invertibility (0.008 mm) and nonzero-positive Jacobian determinants. It also showed improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.7 mm compared to 11.3, 3.1, 5.6, and 2.4 mm for MI FFD, LMI FFD, NMI Demons, and MIND-elastic methods, respectively. Validation in clinical studies demonstrated realistic deformations with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine.
- 2 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (11) , 2413-2424
MIND Demons: Symmetric Diffeomorphic Deformable Registration of MR and CT for Image-Guided Spine Surgery
Intraoperative localization of target anatomy and critical structures defined in preoperative MR/CT images can be achieved through the use of multimodality deformable registration. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality-independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. The method, called MIND Demons, finds a deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the integrated velocity fields, a modality-insensitive similarity function suitable to multimodality images, and smoothness on the diffeomorphisms themselves. Direct optimization without relying on the exponential map and stationary velocity field approximation used in conventional diffeomorphic Demons is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, normalized MI (NMI) Demons, and MIND with a diffusion-based registration method (MIND-elastic). The method yielded sub-voxel invertibility (0.008 mm) and nonzero-positive Jacobian determinants. It also showed improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.7 mm compared to 11.3, 3.1, 5.6, and 2.4 mm for MI FFD, LMI FFD, NMI Demons, and MIND-elastic methods, respectively. Validation in clinical studies demonstrated realistic deformations with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine.
- 1 November 2006
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 70 (2) , 179-190
Reality Augmentation for Medical Procedures: System Architecture, Single Camera Marker Tracking, and System Evaluation
- 1 November 2006
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 70 (2) , 179-190
Reality Augmentation for Medical Procedures: System Architecture, Single Camera Marker Tracking, and System Evaluation
- 1 January 2004
- Vol. 98, 397-403
An AR system with intuitive user interface for manipulation and visualization of 3D medical data.
We report on a stereoscopic video-see-through augmented reality system which we developed for medical applications. Our system allows interactive in-situ visualization of 3D medical imaging data. For high-quality rendering of the augmented scene we utilize the capabilities of the latest graphics card generations. Fast high-precision MPR generation ("multiplanar reconstruction") and volume rendering is realized with OpenGL 3D textures. We provide a tracked hand-held tool to interact with the medical imaging data in its actual location. This tool is represented as a virtual tool in the space of the medical data. The user can assign different functionality to it: select arbitrary MPR cross-sections, guide a local volume rendered cube through the medical data, change the transfer function, etc. Tracking works in conjunction with retroreflective markers, which frame the workspace for head tracking respectively are attached to instruments for tool tracking. We use a single head-mounted tracking camera, which is rigidly fixed to the stereo pair of cameras that provide the live video view of the real scene. The user's spatial perception is based on stereo depth cues as well as on the kinetic depth cues that he receives with the viewpoint variations and the interactive data visualization. The AR system has a compelling real-time performance with 30 stereo-frames/second and exhibits no time lag between the video images and the augmenting graphics. Thus, the physician can interactively explore the medical imaging information in-situ.
- 1 January 2004
- Vol. 98, 397-403
An AR system with intuitive user interface for manipulation and visualization of 3D medical data.
We report on a stereoscopic video-see-through augmented reality system which we developed for medical applications. Our system allows interactive in-situ visualization of 3D medical imaging data. For high-quality rendering of the augmented scene we utilize the capabilities of the latest graphics card generations. Fast high-precision MPR generation ("multiplanar reconstruction") and volume rendering is realized with OpenGL 3D textures. We provide a tracked hand-held tool to interact with the medical imaging data in its actual location. This tool is represented as a virtual tool in the space of the medical data. The user can assign different functionality to it: select arbitrary MPR cross-sections, guide a local volume rendered cube through the medical data, change the transfer function, etc. Tracking works in conjunction with retroreflective markers, which frame the workspace for head tracking respectively are attached to instruments for tool tracking. We use a single head-mounted tracking camera, which is rigidly fixed to the stereo pair of cameras that provide the live video view of the real scene. The user's spatial perception is based on stereo depth cues as well as on the kinetic depth cues that he receives with the viewpoint variations and the interactive data visualization. The AR system has a compelling real-time performance with 30 stereo-frames/second and exhibits no time lag between the video images and the augmenting graphics. Thus, the physician can interactively explore the medical imaging information in-situ.
- 1 January 2003
- Vol. 94, 151-7
An Augmented Reality system for MRI-guided needle biopsies.
A navigation system can increase the speed and accuracy of MR guided interventions that make use of scanners with high-field closed magnets. We report on first needle placement experiments performed with an Augmented Reality (AR) navigation system. AR visualization provides very intuitive guidance, resulting in a faster procedure. The accuracy of the needle placement depends on the registration accuracy of the system. In the present trials, the needle was placed as good as 1mm close to the target center, however in a small number of cases substantially larger errors occurred and were most likely caused by needle bending.
- 1 January 2003
- Vol. 94, 151-7
An Augmented Reality system for MRI-guided needle biopsies.
A navigation system can increase the speed and accuracy of MR guided interventions that make use of scanners with high-field closed magnets. We report on first needle placement experiments performed with an Augmented Reality (AR) navigation system. AR visualization provides very intuitive guidance, resulting in a faster procedure. The accuracy of the needle placement depends on the registration accuracy of the system. In the present trials, the needle was placed as good as 1mm close to the target center, however in a small number of cases substantially larger errors occurred and were most likely caused by needle bending.
- 1 January 2002
- Vol. 85, 455-60
An augmented reality system for ultrasound guided needle biopsies.
We have developed an augmented reality visualization system that helps the physician perform ultrasound guided needle biopsies. For a needle biopsy, the needle has to be inserted into an anatomical target to remove a tissue sample. Ultrasound guidance is routinely used e.g. for breast needle biopsies. The real-time ultrasound images allow the physician to locate the target and to monitor the needle position. Our system uses a combination of an optical laser guide and a virtual guide in the augmented image to provide intuitive guidance for the needle placement. There is no need to track the needle, i.e. there is no need to instrument the needle for tracking. In phantom tests, users have performed well with the system without prior training. This paper describes special features of our system and the workflow for the needle placement procedure.
- 1 January 2002
- Vol. 85, 455-60
An augmented reality system for ultrasound guided needle biopsies.
We have developed an augmented reality visualization system that helps the physician perform ultrasound guided needle biopsies. For a needle biopsy, the needle has to be inserted into an anatomical target to remove a tissue sample. Ultrasound guidance is routinely used e.g. for breast needle biopsies. The real-time ultrasound images allow the physician to locate the target and to monitor the needle position. Our system uses a combination of an optical laser guide and a virtual guide in the augmented image to provide intuitive guidance for the needle placement. There is no need to track the needle, i.e. there is no need to instrument the needle for tracking. In phantom tests, users have performed well with the system without prior training. This paper describes special features of our system and the workflow for the needle placement procedure.