Andrew Nicolaides
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew Nicolaides has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Jasjit S. Suri
Department of ECE, Idaho State University, Pocatello, ID 83209, USA
4 shared publications - Luca Saba
Department of Radiology, University of Cagliari, Italy
4 shared publications Jasjit Suri
3 shared publications- Nilanjan Dey
Techno International New Town
3 shared publications Ajay Gupta
Brain and Mind Research Institute, Weill Cornell Medical College, NY, USA
2 shared publications- Constantinos S. Pattichis
Department of Computer Science, University of Cyprus, Nicosia, Cyprus
2 shared publications
Latest Publications
- 1 April 2015
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 41 (4) , S133
2084743 Diagnostic Preservation Of Atherosclerotic Ultrasound Video For Stroke Telemedicine In Watermarking Framework
- 1 April 2015
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 41 (4) , S133
2084743 Diagnostic Preservation Of Atherosclerotic Ultrasound Video For Stroke Telemedicine In Watermarking Framework
- 1 April 2015
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 41 (4) , S72-S73
2083449 Angiographic Coronary Syntax Score And Atherosclerotic Bulb Plaque in Carotid Ultrasound: a Strong Correlation in Diabetic Patients
- 1 April 2015
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 41 (4) , S72-S73
2083449 Angiographic Coronary Syntax Score And Atherosclerotic Bulb Plaque in Carotid Ultrasound: a Strong Correlation in Diabetic Patients
- 6 January 2013
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 51 (5) , 513-523
Atherosclerotic plaque tissue characterization in 2D ultrasound longitudinal carotid scans for automated classification: a paradigm for stroke risk assessment
In the case of carotid atherosclerosis, to avoid unnecessary surgeries in asymptomatic patients, it is necessary to develop a technique to effectively differentiate symptomatic and asymptomatic plaques. In this paper, we have presented a data mining framework that characterizes the textural differences in these two classes using several grayscale features based on a novel combination of trace transform and fuzzy texture. The features extracted from the delineated plaque regions in B-mode ultrasound images were used to train several classifiers in order to prepare them for classification of new test plaques. Our CAD system was evaluated using two different databases consisting of 146 (44 symptomatic to 102 asymptomatic) and 346 (196 symptomatic and 150 asymptomatic) images. Both these databases differ in the way the ground truth was determined. We obtained classification accuracies of 93.1 and 85.3 %, respectively. The techniques are low cost, easily implementable, objective, and non-invasive. For more objective analysis, we have also developed novel integrated indices using a combination of significant features.
- 6 January 2013
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 51 (5) , 513-523
Atherosclerotic plaque tissue characterization in 2D ultrasound longitudinal carotid scans for automated classification: a paradigm for stroke risk assessment
In the case of carotid atherosclerosis, to avoid unnecessary surgeries in asymptomatic patients, it is necessary to develop a technique to effectively differentiate symptomatic and asymptomatic plaques. In this paper, we have presented a data mining framework that characterizes the textural differences in these two classes using several grayscale features based on a novel combination of trace transform and fuzzy texture. The features extracted from the delineated plaque regions in B-mode ultrasound images were used to train several classifiers in order to prepare them for classification of new test plaques. Our CAD system was evaluated using two different databases consisting of 146 (44 symptomatic to 102 asymptomatic) and 346 (196 symptomatic and 150 asymptomatic) images. Both these databases differ in the way the ground truth was determined. We obtained classification accuracies of 93.1 and 85.3 %, respectively. The techniques are low cost, easily implementable, objective, and non-invasive. For more objective analysis, we have also developed novel integrated indices using a combination of significant features.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7962
Completely automated multiresolution edge snapper (CAMES): a new technique for an accurate carotid ultrasound IMT measurement and its validation on a multi-institutional database
Since 2005, our research team has been developing automated techniques for carotid artery (CA) wall segmentation and intima-media thickness (IMT) measurement. We developed a snake-based technique (which we named CULEX1,2), a method based on an integrated approach of feature extraction, fitting, and classification (which we named CALEX3), and a watershed transform based algorithm4. Each of the previous methods substantially consisted in two distinct stages: Stage-I - Automatic carotid artery detection. In this step, intelligent procedures were adopted to automatically locate the CA in the image frame. Stage-II - CA wall segmentation and IMT measurement. In this second step, the CA distal (or far) wall is segmented in order to trace the lumen-intima (LI) and media-adventitia (MA) boundaries. The distance between the LI/MA borders is the IMT estimation. The aim of this paper is the description of a novel and completely automated technique for carotid artery segmentation and IMT measurement based on an innovative multi-resolution approach.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7962
Completely automated multiresolution edge snapper (CAMES): a new technique for an accurate carotid ultrasound IMT measurement and its validation on a multi-institutional database
Since 2005, our research team has been developing automated techniques for carotid artery (CA) wall segmentation and intima-media thickness (IMT) measurement. We developed a snake-based technique (which we named CULEX1,2), a method based on an integrated approach of feature extraction, fitting, and classification (which we named CALEX3), and a watershed transform based algorithm4. Each of the previous methods substantially consisted in two distinct stages: Stage-I - Automatic carotid artery detection. In this step, intelligent procedures were adopted to automatically locate the CA in the image frame. Stage-II - CA wall segmentation and IMT measurement. In this second step, the CA distal (or far) wall is segmented in order to trace the lumen-intima (LI) and media-adventitia (MA) boundaries. The distance between the LI/MA borders is the IMT estimation. The aim of this paper is the description of a novel and completely automated technique for carotid artery segmentation and IMT measurement based on an innovative multi-resolution approach.
- 18 January 2011
- Published by Springer Nature in Journal of Medical Systems
- Vol. 36 (3) , 1861-1871
Symptomatic vs. Asymptomatic Plaque Classification in Carotid Ultrasound
Quantitative characterization of carotid atherosclerosis and classification into symptomatic or asymptomatic type is crucial in both diagnosis and treatment planning. This paper describes a computer-aided diagnosis (CAD) system which analyzes ultrasound images and classifies them into symptomatic and asymptomatic based on the textural features. The proposed CAD system consists of three modules. The first module is preprocessing, which conditions the images for the subsequent feature extraction. The feature extraction stage uses image texture analysis to calculate Standard deviation, Entropy, Symmetry, and Run Percentage. Finally, classification is performed using AdaBoost and Support Vector Machine for automated decision making. For Adaboost, we compared the performance of five distinct configurations (Least Squares, Maximum- Likelihood, Normal Density Discriminant Function, Pocket, and Stumps) of this algorithm. For Support Vector Machine, we compared the performance using five different configurations (linear kernel, polynomial kernel configurations of different orders and radial basis function kernels). SVM with radial basis function kernel for support vector machine presented the best classification result: classification accuracy of 82.4%, sensitivity of 82.9%, and specificity of 82.1%. We feel that texture features coupled with the Support Vector Machine classifier can be used to identify the plaque tissue type. An Integrated Index, called symptomatic asymptomatic carotid index (SACI), is proposed using texture features to discriminate symptomatic and asymptomatic carotid ultrasound images using just one index or number. We hope this SACI can be used as an adjunct tool by the vascular surgeons for daily screening.
- 18 January 2011
- Published by Springer Nature in Journal of Medical Systems
- Vol. 36 (3) , 1861-1871
Symptomatic vs. Asymptomatic Plaque Classification in Carotid Ultrasound
Quantitative characterization of carotid atherosclerosis and classification into symptomatic or asymptomatic type is crucial in both diagnosis and treatment planning. This paper describes a computer-aided diagnosis (CAD) system which analyzes ultrasound images and classifies them into symptomatic and asymptomatic based on the textural features. The proposed CAD system consists of three modules. The first module is preprocessing, which conditions the images for the subsequent feature extraction. The feature extraction stage uses image texture analysis to calculate Standard deviation, Entropy, Symmetry, and Run Percentage. Finally, classification is performed using AdaBoost and Support Vector Machine for automated decision making. For Adaboost, we compared the performance of five distinct configurations (Least Squares, Maximum- Likelihood, Normal Density Discriminant Function, Pocket, and Stumps) of this algorithm. For Support Vector Machine, we compared the performance using five different configurations (linear kernel, polynomial kernel configurations of different orders and radial basis function kernels). SVM with radial basis function kernel for support vector machine presented the best classification result: classification accuracy of 82.4%, sensitivity of 82.9%, and specificity of 82.1%. We feel that texture features coupled with the Support Vector Machine classifier can be used to identify the plaque tissue type. An Integrated Index, called symptomatic asymptomatic carotid index (SACI), is proposed using texture features to discriminate symptomatic and asymptomatic carotid ultrasound images using just one index or number. We hope this SACI can be used as an adjunct tool by the vascular surgeons for daily screening.
- 1 September 2010
- Published by Bentham Science Publishers Ltd. in Current Vascular Pharmacology
- Vol. 8 (5) , 682-691
ESVS Guidelines: Section B - Diagnosis and Investigation of Patients with Carotid Stenosis
Herein, we present the European Society for Vascular Surgery Guidelines pertinent to the secondary prevention of cerebrovascular events in patients with carotid artery stenosis including lipid lowering therapy, antiplatelet therapy and other risk factor modification. These recommendations are based on current evidence from clinical trials. There is a need for aggressive prevention treatment in patients with carotid artery disease. We also discuss the diagnosis and grading of carotid artery stenosis.
- 1 September 2010
- Published by Bentham Science Publishers Ltd. in Current Vascular Pharmacology
- Vol. 8 (5) , 682-691
ESVS Guidelines: Section B - Diagnosis and Investigation of Patients with Carotid Stenosis
Herein, we present the European Society for Vascular Surgery Guidelines pertinent to the secondary prevention of cerebrovascular events in patients with carotid artery stenosis including lipid lowering therapy, antiplatelet therapy and other risk factor modification. These recommendations are based on current evidence from clinical trials. There is a need for aggressive prevention treatment in patients with carotid artery disease. We also discuss the diagnosis and grading of carotid artery stenosis.
- Open Access
- 28 January 2006
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 4 (1) , 8
Effect of zooming on texture features of ultrasonic images
Background: Unstable carotid plaques on subjective, visual, assessment using B-mode ultrasound scanning appear as echolucent and heterogeneous. Although previous studies on computer assisted plaque characterisation have standardised B-mode images for brightness, improving the objective assessment of echolucency, little progress has been made towards standardisation of texture analysis methods, which assess plaque heterogeneity. The aim of the present study was to investigate the influence of image zooming during ultrasound scanning on textural features and to test whether or not resolution standardisation decreases the variability introduced. Methods: Eighteen still B-mode images of carotid plaques were zoomed during carotid scanning (zoom factor 1.3) and both images were transferred to a PC and normalised. Using bilinear and bicubic interpolation, the original images were interpolated in a process of simulating off-line zoom using the same interpolation factor. With the aid of the colour-coded image, carotid plaques of the original, zoomed and two resampled images for each case were outlined and histogram, first order and second order statistics were subsequently calculated. Results: Most second order statistics (21/25, 84%) were significantly (p < 0.05) sensitive to image zooming during scanning, in contrast to histogram and first order statistics (4/25, 16%, p < 0.001, Fisher's exact test). Median (interquartile range) change of those features sensitive to zooming was 18.14% (4.94–28.43). Image interpolation restored these changes, the bicubic interpolation being superior compared to bilinear interpolation (p = 0.036). Conclusion: Texture analysis of ultrasonic plaques should be performed under standardised resolution settings; otherwise a resolution normalisation algorithm should be applied.
- 28 January 2006
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 4 (1) , 8
Open AccessEffect of zooming on texture features of ultrasonic images
Background: Unstable carotid plaques on subjective, visual, assessment using B-mode ultrasound scanning appear as echolucent and heterogeneous. Although previous studies on computer assisted plaque characterisation have standardised B-mode images for brightness, improving the objective assessment of echolucency, little progress has been made towards standardisation of texture analysis methods, which assess plaque heterogeneity. The aim of the present study was to investigate the influence of image zooming during ultrasound scanning on textural features and to test whether or not resolution standardisation decreases the variability introduced. Methods: Eighteen still B-mode images of carotid plaques were zoomed during carotid scanning (zoom factor 1.3) and both images were transferred to a PC and normalised. Using bilinear and bicubic interpolation, the original images were interpolated in a process of simulating off-line zoom using the same interpolation factor. With the aid of the colour-coded image, carotid plaques of the original, zoomed and two resampled images for each case were outlined and histogram, first order and second order statistics were subsequently calculated. Results: Most second order statistics (21/25, 84%) were significantly (p < 0.05) sensitive to image zooming during scanning, in contrast to histogram and first order statistics (4/25, 16%, p < 0.001, Fisher's exact test). Median (interquartile range) change of those features sensitive to zooming was 18.14% (4.94–28.43). Image interpolation restored these changes, the bicubic interpolation being superior compared to bilinear interpolation (p = 0.036). Conclusion: Texture analysis of ultrasonic plaques should be performed under standardised resolution settings; otherwise a resolution normalisation algorithm should be applied.