Dietmar Wagner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dietmar Wagner has a total of 306 co-authors. Here are the top co-authors by number of shared publications:
J. Stober
Max-Planck-Institut für Plasmaphysik, Garching, Germany
11 shared publicationsF. Leuterer
Max-Planck-Institut für Plasmaphysik, Garching, Germany
10 shared publications- Manfred Thumm
Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
10 shared publications W. Kasparek
Institut für Grenzflächenverfahrenstechnik und Plasmatechnologie, Universität Stuttgart, Stuttgart, Germany
8 shared publicationsF. Monaco
Max-Planck-Institut für Plasmaphysik, Garching, Germany
7 shared publications- Hartmut Zohm
Max-Planck-Institut für Plasmaphysik
5 shared publications
Latest Publications
- Open Access
- 15 November 2024
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 313, 04001
In-situ Low Power Tests of the ASDEX Upgrade ECRH Transmission Lines
An Electron Cyclotron Resonance Heating (ECRH) system employing 8 gyrotrons is in routine operation at the ASDEX Upgrade tokamak at IPP Garching. The gyrotrons are of two-frequency type operating at 105 and 140 GHz with a maximum output power of up to 1 MW and 10 s pulse length. The gyrotron output beams are coupled to 8 waveguide transmission lines via quasi-optical Matching Optics Units (MOUs). The oversized corrugated HE11 waveguides with a diameter of 87 mm are operated at atmospheric pressure with overall lengths between 65 and 103 meters. The number of quasi-optical miter bends per line is between 6 and 8. High mode purity in the transmission lines is critical with respect to both, losses and atmospheric breakdowns in the waveguides. Beam measurements at low power have been performed along the transmission lines and are compared to high power measurements. Near-field calculations and measurements of mm-wave beams radiated from open-ended HE11 waveguides show, that varying intensity patterns determine the distribution of Ohmic loading in compact mm-wave beam launching antennas, where the first mirror is located in the reactive near-field or close to the Fresnel maximum.
- 15 November 2024
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 313, 04001
Open AccessIn-situ Low Power Tests of the ASDEX Upgrade ECRH Transmission Lines
An Electron Cyclotron Resonance Heating (ECRH) system employing 8 gyrotrons is in routine operation at the ASDEX Upgrade tokamak at IPP Garching. The gyrotrons are of two-frequency type operating at 105 and 140 GHz with a maximum output power of up to 1 MW and 10 s pulse length. The gyrotron output beams are coupled to 8 waveguide transmission lines via quasi-optical Matching Optics Units (MOUs). The oversized corrugated HE11 waveguides with a diameter of 87 mm are operated at atmospheric pressure with overall lengths between 65 and 103 meters. The number of quasi-optical miter bends per line is between 6 and 8. High mode purity in the transmission lines is critical with respect to both, losses and atmospheric breakdowns in the waveguides. Beam measurements at low power have been performed along the transmission lines and are compared to high power measurements. Near-field calculations and measurements of mm-wave beams radiated from open-ended HE11 waveguides show, that varying intensity patterns determine the distribution of Ohmic loading in compact mm-wave beam launching antennas, where the first mirror is located in the reactive near-field or close to the Fresnel maximum.
- 12 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (6) , 2558-2566
Single- and Two-Frequency Sub-THz Waveguide Notch Filters With Rejection Frequencies Within and Beyond the Passband
Notch filters are a key component in millimeter-wave plasma diagnostics systems for magnetically confined fusion plasmas. They are required to protect sensitive millimeter-wave receivers from stray radiation of electron cyclotron heating systems. These heating systems employ gyrotrons that emit strong millimeter-wave radiation (90 dBm) in one or, in the case of modern step-tunable gyrotrons, several narrowband frequency lines. In this article, we describe the design and performance of notch filters based on waveguide technology, operating in the F-band (90–140 GHz), that reject one or two selectable frequencies in the passband. We also present the solution for a filter where the rejected frequencies are outside of the passband of the plasma diagnostics. This is demonstrated for a filter operating in the W-band (75–110 GHz). To fully protect the diagnostic systems, typical stopbands with not less than 60-dB rejection and at least 500-MHz width are required.
- 12 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (6) , 2558-2566
Single- and Two-Frequency Sub-THz Waveguide Notch Filters With Rejection Frequencies Within and Beyond the Passband
Notch filters are a key component in millimeter-wave plasma diagnostics systems for magnetically confined fusion plasmas. They are required to protect sensitive millimeter-wave receivers from stray radiation of electron cyclotron heating systems. These heating systems employ gyrotrons that emit strong millimeter-wave radiation (90 dBm) in one or, in the case of modern step-tunable gyrotrons, several narrowband frequency lines. In this article, we describe the design and performance of notch filters based on waveguide technology, operating in the F-band (90–140 GHz), that reject one or two selectable frequencies in the passband. We also present the solution for a filter where the rejected frequencies are outside of the passband of the plasma diagnostics. This is demonstrated for a filter operating in the W-band (75–110 GHz). To fully protect the diagnostic systems, typical stopbands with not less than 60-dB rejection and at least 500-MHz width are required.
- 16 December 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (2) , 85-96
Frequency and mode measurement techniques for megawatt-class gyrotrons
State-of-the-art vacuum electron tubes such as gyrotrons, deliver RF output powers up to more than 2 MW at frequencies up to 170 GHz. In terms of the very high power levels, a proper verification of the gyrotron components itself and measurements during gyrotron operation are vital to prevent possible fatal errors. Several basic RF measurement setups, which are used at IHM/KIT, are discussed. Currently, their upper frequency limit is 175 GHz. In terms of future gyrotron operation above 200 GHz, upgrades of the measurement setups for operation up to 260–330 GHz are prepared. The experimental devices discussed herein are a quasi-optical mode generator for the verification of the quasi-optical gyrotron output system, the window measurement test stand to verify the ceramic gyrotron output window and the frequency diagnostic system to measure the operating frequency and thereby the excited mode.
- 16 December 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (2) , 85-96
Frequency and mode measurement techniques for megawatt-class gyrotrons
State-of-the-art vacuum electron tubes such as gyrotrons, deliver RF output powers up to more than 2 MW at frequencies up to 170 GHz. In terms of the very high power levels, a proper verification of the gyrotron components itself and measurements during gyrotron operation are vital to prevent possible fatal errors. Several basic RF measurement setups, which are used at IHM/KIT, are discussed. Currently, their upper frequency limit is 175 GHz. In terms of future gyrotron operation above 200 GHz, upgrades of the measurement setups for operation up to 260–330 GHz are prepared. The experimental devices discussed herein are a quasi-optical mode generator for the verification of the quasi-optical gyrotron output system, the window measurement test stand to verify the ceramic gyrotron output window and the frequency diagnostic system to measure the operating frequency and thereby the excited mode.
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 68 (10) , 5220-5226
Improvement of the Output Mode Purity of a Complex-Cavity Resonator for a Frequency-Tunable Sub-THz Gyrotron
One way to improve the mode selection in terahertz gyrotrons is the use of stepped cavity resonators that satisfy the resonance condition for two modes with the same azimuthal but different radial indices. Such sectioned resonators, or complex cavities, were analyzed in detail by several authors, recently and in the past. One common problem for such designs is the excitation of unwanted modes by both the stepped cavity structure and the cavity input and output tapers. Mode conversion becomes especially a severe problem for higher-order resonant modes in highly oversized resonators. In this article, we introduce ways to minimize the unwanted mode conversion in both the radial step of the cavity as well as in the tapered sections of the cavity and the up-taper to the collector and output window. Frequency tuning between 391.5 and 393.5 GHz has been achieved by operation at different axial mode numbers of the mode pair TE $_{8,4}$ /TE $_{8,5}$ . Due to their intrinsic higher output mode purity, the so-called antiphase modes of the complex cavity have been chosen for this output mode purity study.- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 68 (10) , 5220-5226
Improvement of the Output Mode Purity of a Complex-Cavity Resonator for a Frequency-Tunable Sub-THz Gyrotron
One way to improve the mode selection in terahertz gyrotrons is the use of stepped cavity resonators that satisfy the resonance condition for two modes with the same azimuthal but different radial indices. Such sectioned resonators, or complex cavities, were analyzed in detail by several authors, recently and in the past. One common problem for such designs is the excitation of unwanted modes by both the stepped cavity structure and the cavity input and output tapers. Mode conversion becomes especially a severe problem for higher-order resonant modes in highly oversized resonators. In this article, we introduce ways to minimize the unwanted mode conversion in both the radial step of the cavity as well as in the tapered sections of the cavity and the up-taper to the collector and output window. Frequency tuning between 391.5 and 393.5 GHz has been achieved by operation at different axial mode numbers of the mode pair TE $_{8,4}$ /TE $_{8,5}$ . Due to their intrinsic higher output mode purity, the so-called antiphase modes of the complex cavity have been chosen for this output mode purity study.- Open Access
- 8 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Recent Development of a 1.5 MW, 140 GHz Continuous-Wave Gyrotron for the Upgraded ECRH System at W7-X
To increase the total injected Electron Cyclotron Resonance Heating (ECRH) power in the plasma of the nuclear fusion experiment Wendelstein 7-X (W7-X), an upgrade of the existing gyrotron installation is in progress. The existing ECRH system, currently equipped with ten one-MW-class, 140 GHz continuous wave (CW) gyrotrons, will be augmented by enhanced 1.5 MW tubes, which are based on the successful existing 1 MW gyrotron design.
- 8 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Open AccessRecent Development of a 1.5 MW, 140 GHz Continuous-Wave Gyrotron for the Upgraded ECRH System at W7-X
To increase the total injected Electron Cyclotron Resonance Heating (ECRH) power in the plasma of the nuclear fusion experiment Wendelstein 7-X (W7-X), an upgrade of the existing gyrotron installation is in progress. The existing ECRH system, currently equipped with ten one-MW-class, 140 GHz continuous wave (CW) gyrotrons, will be augmented by enhanced 1.5 MW tubes, which are based on the successful existing 1 MW gyrotron design.
- 16 September 2020
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 41 (12) , 1591-1592
Correction to: “A Compact Two-Frequency Notch Filter for Millimeter Wave Plasma Diagnostics”
- 16 September 2020
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 41 (12) , 1591-1592
Correction to: “A Compact Two-Frequency Notch Filter for Millimeter Wave Plasma Diagnostics”
- Open Access
- 27 May 2020
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 41 (7) , 741-749
A Compact Two-Frequency Notch Filter for Millimeter Wave Plasma Diagnostics
Sensitive millimeter wave diagnostics in magnetic confinement plasma fusion experiments need protection from gyrotron stray radiation in the plasma vessel. Modern electron cyclotron resonance heating (ECRH) systems take advantage of multi-frequency gyrotrons. This means that the frequency band of some millimeter wave diagnostics contains more than one narrow-band gyrotron-frequency line, which needs to be effectively suppressed. A compact standard waveguide notch filter based on coupled waveguide resonators with rectangular cross-section is presented which can provide very high suppression of several gyrotron frequencies and has low insertion loss of the passband.
- 27 May 2020
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 41 (7) , 741-749
Open AccessA Compact Two-Frequency Notch Filter for Millimeter Wave Plasma Diagnostics
Sensitive millimeter wave diagnostics in magnetic confinement plasma fusion experiments need protection from gyrotron stray radiation in the plasma vessel. Modern electron cyclotron resonance heating (ECRH) systems take advantage of multi-frequency gyrotrons. This means that the frequency band of some millimeter wave diagnostics contains more than one narrow-band gyrotron-frequency line, which needs to be effectively suppressed. A compact standard waveguide notch filter based on coupled waveguide resonators with rectangular cross-section is presented which can provide very high suppression of several gyrotron frequencies and has low insertion loss of the passband.
- Open Access
- 4 August 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 149, 03004
Extension of the multi-frequency ECRH system at ASDEX upgrade
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 4 August 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 149, 03004
Open AccessExtension of the multi-frequency ECRH system at ASDEX upgrade
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Investigation of a broadband double-disc diamond window unit
In this paper we investigate the potential causes of failure of a diamond window unit employed in the experimental tokamak ASDEX Upgrade in Garching, Germany. The window unit features a double-disc configuration that allows for a more complex transmission spectrum than with a single disc and is used in conjunction with step-tunable gyrotrons for electron-cyclotron heating of fusion plasmas. The window unit failed during high-power operation as a consequence of a crack in one of the two diamond discs. The event that initiated the crack is unknown. Two possible reasons have been investigated in detail: high stress on the diamond due to bad quality of the brazing and due to localized power depositions. The first is investigated by computer tomography imaging of the brazing, the second by means of a custom ray-tracing code that uses a “hybrid” approach that accounts for the waves' phase, thus reproducing the effects of interference.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Investigation of a broadband double-disc diamond window unit
In this paper we investigate the potential causes of failure of a diamond window unit employed in the experimental tokamak ASDEX Upgrade in Garching, Germany. The window unit features a double-disc configuration that allows for a more complex transmission spectrum than with a single disc and is used in conjunction with step-tunable gyrotrons for electron-cyclotron heating of fusion plasmas. The window unit failed during high-power operation as a consequence of a crack in one of the two diamond discs. The event that initiated the crack is unknown. Two possible reasons have been investigated in detail: high stress on the diamond due to bad quality of the brazing and due to localized power depositions. The first is investigated by computer tomography imaging of the brazing, the second by means of a custom ray-tracing code that uses a “hybrid” approach that accounts for the waves' phase, thus reproducing the effects of interference.
- Open Access
- 28 October 2016
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 38 (2) , 191-205
Minimization of the Ohmic Loss of Grooved Polarizer Mirrors in High-Power ECRH Systems
- 28 October 2016
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 38 (2) , 191-205
Open AccessMinimization of the Ohmic Loss of Grooved Polarizer Mirrors in High-Power ECRH Systems