Thomas Binder
Research Subjects
Thomas Binder has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Georg Goliasch
Department of Internal Medicine II, Clinical Division of Cardiology, Medical University of Vienna, 1090 Vienna, Austria
5 shared publications - Matthias Schneider
Deutsches Herzzentrum der Charité, Department of Cardiology, Angiology and Intensive Care Medicine, Berlin, Germany.
4 shared publications - Christian Hengstenberg
Medical University of Vienna
3 shared publications Christina Binder
Department of Internal Medicine, Division of Cardiology, Medical University of Vienna , Vienna
3 shared publications- Ali Hamadanchi
Department of Cardiology, University of Jena, Jena, Germany
2 shared publications - Andreas Hagendorff
Klinik und Poliklinik für Kardiologie, Universitätsklinikum Leipzig, Leipzig, Germany
2 shared publications
Latest Publications
- Open Access
- 13 January 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 3 (1) , qyaf064
Seeing through the leak: a global perspective on aortic regurgitation assessment
Aims: Despite established guidelines, the echocardiographic quantification of aortic regurgitation (AR) remains challenging in clinical practice. While artificial intelligence (AI) solutions are being developed to support diagnostic assessment using echocardiography, their successful implementation will depend on understanding both current diagnostic challenges and clinician attitudes towards AI adoption. This study aimed to evaluate current practices in AR assessment, identify key challenges, and assess educational needs in AR diagnostics, while also investigating how healthcare professionals perceive AI assistance compared with human expert assessment. Methods and results: We conducted a global online survey among sonographers and physicians. Participants answered questions about their current AR quantification practices, perceived limitations, and willingness to seek assistance from experienced colleagues or AI tools. Additionally, they were asked to grade AR severity in three sample echocardiographic cases. Among 1032 participants from 104 countries, 42% considered AR the most challenging valve lesion to assess. While guidelines recommend a multi-parameter approach, most practitioners relied primarily on visual colour jet assessment (51.5%) and basic measurements, with advanced quantitative parameters being notably underutilized (21.7%). Main limitations included eccentric jets (61.3%) and poor image quality (49.8%). Case-based assessments revealed significant variability in AR grading across experience levels (P < 0.001). Participants showed high confidence in both experienced colleagues and validated AI models (median confidence score of 7/10 for both) but less trust in newly developed AI tools (median confidence score 5/10). Conclusion: This study demonstrates a substantial gap between guideline recommendations and clinical practice in AR quantification, with significant grading variability across and within expertise levels. While practitioners remain sceptical of newly developed AI tools, their openness to validated AI models suggests a potential pathway for improving the consistency of AR assessment.
- 13 January 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 3 (1) , qyaf064
Open AccessSeeing through the leak: a global perspective on aortic regurgitation assessment
Aims: Despite established guidelines, the echocardiographic quantification of aortic regurgitation (AR) remains challenging in clinical practice. While artificial intelligence (AI) solutions are being developed to support diagnostic assessment using echocardiography, their successful implementation will depend on understanding both current diagnostic challenges and clinician attitudes towards AI adoption. This study aimed to evaluate current practices in AR assessment, identify key challenges, and assess educational needs in AR diagnostics, while also investigating how healthcare professionals perceive AI assistance compared with human expert assessment. Methods and results: We conducted a global online survey among sonographers and physicians. Participants answered questions about their current AR quantification practices, perceived limitations, and willingness to seek assistance from experienced colleagues or AI tools. Additionally, they were asked to grade AR severity in three sample echocardiographic cases. Among 1032 participants from 104 countries, 42% considered AR the most challenging valve lesion to assess. While guidelines recommend a multi-parameter approach, most practitioners relied primarily on visual colour jet assessment (51.5%) and basic measurements, with advanced quantitative parameters being notably underutilized (21.7%). Main limitations included eccentric jets (61.3%) and poor image quality (49.8%). Case-based assessments revealed significant variability in AR grading across experience levels (P < 0.001). Participants showed high confidence in both experienced colleagues and validated AI models (median confidence score of 7/10 for both) but less trust in newly developed AI tools (median confidence score 5/10). Conclusion: This study demonstrates a substantial gap between guideline recommendations and clinical practice in AR quantification, with significant grading variability across and within expertise levels. While practitioners remain sceptical of newly developed AI tools, their openness to validated AI models suggests a potential pathway for improving the consistency of AR assessment.
- Open Access
- 28 August 2024
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 114 (1) , 25-40
Echocardiographic assessment of left atrial appendage morphology and function—an expert proposal by the German Working Group of Cardiovascular Ultrasound
The left atrial appendage is a blind ending cardiac structure prone to blood stasis due to its morphology. This structure is a preferred region of thrombogenesis in relation to reduced myocardial contractility of the atrial wall. Blood stasis occurs primarily in low flow conditions. One of the tasks of echocardiography is the analysis of morphology and function of the left atrial appendage. The detection of thrombi by echocardiography is difficult and must be carried out thoroughly and carefully to avoid potential complications—especially in the context of rhythm control. The assessment of thromboembolic risk, especially in patients with unknown and presumed atrial fibrillation is a second challenge by characterizing atrial function and flow conditions in the left atrial appendage. Thus, this proposal focuses on the obvious problems of echocardiography when assessing left atrial appendage and the role of this method in planning a potential interventional closure of left atrial appendage.
- 28 August 2024
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 114 (1) , 25-40
Open AccessEchocardiographic assessment of left atrial appendage morphology and function—an expert proposal by the German Working Group of Cardiovascular Ultrasound
The left atrial appendage is a blind ending cardiac structure prone to blood stasis due to its morphology. This structure is a preferred region of thrombogenesis in relation to reduced myocardial contractility of the atrial wall. Blood stasis occurs primarily in low flow conditions. One of the tasks of echocardiography is the analysis of morphology and function of the left atrial appendage. The detection of thrombi by echocardiography is difficult and must be carried out thoroughly and carefully to avoid potential complications—especially in the context of rhythm control. The assessment of thromboembolic risk, especially in patients with unknown and presumed atrial fibrillation is a second challenge by characterizing atrial function and flow conditions in the left atrial appendage. Thus, this proposal focuses on the obvious problems of echocardiography when assessing left atrial appendage and the role of this method in planning a potential interventional closure of left atrial appendage.
- Open Access
- 26 August 2024
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 114 (1) , 4-24
Echocardiographic assessment of atrial, ventricular, and valvular function in patients with atrial fibrillation—an expert proposal by the german working group of cardiovascular ultrasound
Echocardiography in patients with atrial fibrillation is challenging due to the varying heart rate. Thus, the topic of this expert proposal focuses on an obvious gap in the current recommendations about diagnosis and treatment of atrial fibrillation (AF)—the peculiarities and difficulties of echocardiographic imaging. The assessment of systolic and diastolic function—especially in combination with valvular heart diseases—by echocardiography can basically be done by averaging the results of echocardiographic measurements of the respective parameters or by the index beat approach, which uses a representative cardiac cycle for measurement. Therefore, a distinction must be made between the functionally relevant status, which is characterized by the averaging method, and the best possible hemodynamic status, which is achieved with the most optimal left ventricular (LV) filling according to the index beat method with longer previous RR intervals. This proposal focuses on left atrial and left ventricular function and deliberately excludes problems of echocardiography when assessing left atrial appendage in terms of its complexity. Echocardiography of the left atrial appendage is therefore reserved for its own expert proposal.
- 26 August 2024
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 114 (1) , 4-24
Open AccessEchocardiographic assessment of atrial, ventricular, and valvular function in patients with atrial fibrillation—an expert proposal by the german working group of cardiovascular ultrasound
Echocardiography in patients with atrial fibrillation is challenging due to the varying heart rate. Thus, the topic of this expert proposal focuses on an obvious gap in the current recommendations about diagnosis and treatment of atrial fibrillation (AF)—the peculiarities and difficulties of echocardiographic imaging. The assessment of systolic and diastolic function—especially in combination with valvular heart diseases—by echocardiography can basically be done by averaging the results of echocardiographic measurements of the respective parameters or by the index beat approach, which uses a representative cardiac cycle for measurement. Therefore, a distinction must be made between the functionally relevant status, which is characterized by the averaging method, and the best possible hemodynamic status, which is achieved with the most optimal left ventricular (LV) filling according to the index beat method with longer previous RR intervals. This proposal focuses on left atrial and left ventricular function and deliberately excludes problems of echocardiography when assessing left atrial appendage in terms of its complexity. Echocardiography of the left atrial appendage is therefore reserved for its own expert proposal.
- Open Access
- 29 October 2021
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 133 (23-24) , 1298-1309
Point of care echocardiography and lung ultrasound in critically ill patients with COVID-19
Summary: Hundreds of millions got infected, and millions have died worldwide and still the number of cases is rising.Chest radiographs and computed tomography (CT) are useful for imaging the lung but their use in infectious diseases is limited due to hygiene and availability.Lung ultrasound has been shown to be useful in the context of the pandemic, providing clinicians with valuable insights and helping identify complications such as pleural effusion in heart failure or bacterial superinfections. Moreover, lung ultrasound is useful for identifying possible complications of procedures, in particular, pneumothorax.Associations between coronavirus disease 2019 (COVID-19) and cardiac complications, such as acute myocardial infarction and myocarditis, have been reported. As such, point of care echocardiography as well as a comprehensive approach in later stages of the disease provide important information for optimally diagnosing and treating complications of COVID-19.In our experience, lung ultrasound in combination with echocardiography, has a great impact on treatment decisions. In the acute state as well as in the follow-up setting after a severe or critical state of COVID-19, ultrasound can be of great impact to monitor the progression and regression of disease.
- 29 October 2021
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 133 (23-24) , 1298-1309
Open AccessPoint of care echocardiography and lung ultrasound in critically ill patients with COVID-19
Summary: Hundreds of millions got infected, and millions have died worldwide and still the number of cases is rising.Chest radiographs and computed tomography (CT) are useful for imaging the lung but their use in infectious diseases is limited due to hygiene and availability.Lung ultrasound has been shown to be useful in the context of the pandemic, providing clinicians with valuable insights and helping identify complications such as pleural effusion in heart failure or bacterial superinfections. Moreover, lung ultrasound is useful for identifying possible complications of procedures, in particular, pneumothorax.Associations between coronavirus disease 2019 (COVID-19) and cardiac complications, such as acute myocardial infarction and myocarditis, have been reported. As such, point of care echocardiography as well as a comprehensive approach in later stages of the disease provide important information for optimally diagnosing and treating complications of COVID-19.In our experience, lung ultrasound in combination with echocardiography, has a great impact on treatment decisions. In the acute state as well as in the follow-up setting after a severe or critical state of COVID-19, ultrasound can be of great impact to monitor the progression and regression of disease.
- Open Access
- 24 May 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (11) , 2266
Prognostic Value of Echocardiographic Right Ventricular Function Parameters in the Presence of Severe Tricuspid Regurgitation
Background: Presence of severe tricuspid regurgitation (TR) has a significant impact on assessment of right ventricular function (RVF) in transthoracic echocardiography (TTE). High trans-valvular pendulous volume leads to backward-unloading of the right ventricle. Consequently, established cut-offs for normal systolic performance may overestimate true systolic RVF. Methods: A retrospective analysis was performed entailing all patients who underwent TTE at our institution between 1 January 2013 and 31 December 2016. Only patients with normal left ventricular systolic function and with no other valvular lesion were included. All recorded loops were re-read by one experienced examiner. Patients without severe TR (defined as vena contracta width ≥7 mm) were excluded. All-cause 2-year mortality was chosen as the end-point. The prognostic value of several RVF parameters was tested. Results: The final cohort consisted of 220 patients, 88/220 (40%) were male. Median age was 69 years (IQR 52–79), all-cause two-year mortality was 29%, median TAPSE was 19 mm (15–22) and median FAC was 42% (30–52). In multivariate analysis, TAPSE with the cutoff 17 mm and FAC with the cutoff 35% revealed non-significant hazard ratios (HR) of 0.75 (95%CI 0.396–1.421, p = 0.38) and 0.845 (95%CI 0.383–1.867, p = 0.68), respectively. TAPSE with the cutoff 19 mm and visual eyeballing significantly predicted survival with HRs of 0.512 (95%CI 0.296–0.886, p = 0.017) and 1.631 (95%CI 1.101–2.416, p = 0.015), respectively. Conclusions: This large-scale all-comer study confirms that RVF is one of the main drivers of mortality in patients with severe isolated TR. However, the current cut-offs for established echocardiographic parameters did not predict survival. Further studies should investigate the prognostic value of higher thresholds for RVF parameters in these patients.
- 24 May 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (11) , 2266
Open AccessPrognostic Value of Echocardiographic Right Ventricular Function Parameters in the Presence of Severe Tricuspid Regurgitation
Background: Presence of severe tricuspid regurgitation (TR) has a significant impact on assessment of right ventricular function (RVF) in transthoracic echocardiography (TTE). High trans-valvular pendulous volume leads to backward-unloading of the right ventricle. Consequently, established cut-offs for normal systolic performance may overestimate true systolic RVF. Methods: A retrospective analysis was performed entailing all patients who underwent TTE at our institution between 1 January 2013 and 31 December 2016. Only patients with normal left ventricular systolic function and with no other valvular lesion were included. All recorded loops were re-read by one experienced examiner. Patients without severe TR (defined as vena contracta width ≥7 mm) were excluded. All-cause 2-year mortality was chosen as the end-point. The prognostic value of several RVF parameters was tested. Results: The final cohort consisted of 220 patients, 88/220 (40%) were male. Median age was 69 years (IQR 52–79), all-cause two-year mortality was 29%, median TAPSE was 19 mm (15–22) and median FAC was 42% (30–52). In multivariate analysis, TAPSE with the cutoff 17 mm and FAC with the cutoff 35% revealed non-significant hazard ratios (HR) of 0.75 (95%CI 0.396–1.421, p = 0.38) and 0.845 (95%CI 0.383–1.867, p = 0.68), respectively. TAPSE with the cutoff 19 mm and visual eyeballing significantly predicted survival with HRs of 0.512 (95%CI 0.296–0.886, p = 0.017) and 1.631 (95%CI 1.101–2.416, p = 0.015), respectively. Conclusions: This large-scale all-comer study confirms that RVF is one of the main drivers of mortality in patients with severe isolated TR. However, the current cut-offs for established echocardiographic parameters did not predict survival. Further studies should investigate the prognostic value of higher thresholds for RVF parameters in these patients.
- Open Access
- 31 December 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (1) , 107
Systematic Evaluation of Systemic Right Ventricular Function
Background: The right ventricle serves as the subaortic systemic ventricle (sysRV) in patients with congenitally corrected transposition of the great arteries (ccTGA) and in patients with transposition of the great arteries (TGA) surgically repaired by an atrial switch. SysRV can lead to late complications, primarily heart failure, significant regurgitation of the systemic atrioventricular (AV) valve, and ventricular arrhythmias with sudden cardiac death. We sought to investigate the value of 2D- and 3D-echocardiographic parameters of sysRV function. Methods: Consecutive adult patients with sysRV who presented at the adult congenital heart disease outpatient clinic were prospectively enrolled. All patients received comprehensive transthoracic echocardiography, including 3D-echocardiography, cardiac magnetic-resonance-imaging (CMR), cardiopulmonary-exercise-testing, and blood analysis for NT-proBNP. Results. A total of 27 patients were included, 18 with TGA and nine with ccTGA. Median age was 37 years (Q1 = 31, Q3 = 44), 44% were male, median NT-proBNP was 189 pg/mL (Q1 = 155, Q3 = 467); sufficient 3D-echocardiography datasets were acquired in 78% of patients. All echocardiographic 2D and 3D volumetric function parameters correlated with CMR data, whereas a correlation was not seen with any of the longitudinal function parameters. NT-proBNP correlated with tricuspid annular plane systolic excursion (r = −0.43, p = 0.02) and CMR ejection fraction (EF) (r = −0.62, p = 0.003). Conclusion: Systematic evaluation of sysRV is complex and should include not only volumetric parameters but also parameters of longitudinal function in addition to measurement of NT-proBNP. In patients with good image quality, 3D-echocardiography can be used to assess volumes and EF.
- 31 December 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (1) , 107
Open AccessSystematic Evaluation of Systemic Right Ventricular Function
Background: The right ventricle serves as the subaortic systemic ventricle (sysRV) in patients with congenitally corrected transposition of the great arteries (ccTGA) and in patients with transposition of the great arteries (TGA) surgically repaired by an atrial switch. SysRV can lead to late complications, primarily heart failure, significant regurgitation of the systemic atrioventricular (AV) valve, and ventricular arrhythmias with sudden cardiac death. We sought to investigate the value of 2D- and 3D-echocardiographic parameters of sysRV function. Methods: Consecutive adult patients with sysRV who presented at the adult congenital heart disease outpatient clinic were prospectively enrolled. All patients received comprehensive transthoracic echocardiography, including 3D-echocardiography, cardiac magnetic-resonance-imaging (CMR), cardiopulmonary-exercise-testing, and blood analysis for NT-proBNP. Results. A total of 27 patients were included, 18 with TGA and nine with ccTGA. Median age was 37 years (Q1 = 31, Q3 = 44), 44% were male, median NT-proBNP was 189 pg/mL (Q1 = 155, Q3 = 467); sufficient 3D-echocardiography datasets were acquired in 78% of patients. All echocardiographic 2D and 3D volumetric function parameters correlated with CMR data, whereas a correlation was not seen with any of the longitudinal function parameters. NT-proBNP correlated with tricuspid annular plane systolic excursion (r = −0.43, p = 0.02) and CMR ejection fraction (EF) (r = −0.62, p = 0.003). Conclusion: Systematic evaluation of sysRV is complex and should include not only volumetric parameters but also parameters of longitudinal function in addition to measurement of NT-proBNP. In patients with good image quality, 3D-echocardiography can be used to assess volumes and EF.
- Open Access
- 6 September 2018
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 35 (1) , 49-56
Echocardiographic assessment of right ventricular function: current clinical practice
Echocardiographic evaluation of right ventricular (RV) function is a challenge due to the complex anatomy of the RV. Several transthoracic echocardiographic methods have been suggested for the quantification of RV function. However, many of the parameters are time consuming and need dedicated hardware and software. We suspected that the majority of the established markers are not used on a wide basis. In a multinational online survey, we evaluated the use of current clinical standards for the quantification of RV function in clinical practice. Through the network of an Ultrasound Online Teaching Platform, echocardiographers were invited to participate in an open online survey. The participants were asked about the parameters (eyeballing, TAPSE, S′, fractional area change, RIMP, 3D-EF, dp/dt, longitudinal strain) they used in clinical practice. A total of 1150 participants from 109 countries completed the survey. Only eyeballing (72%), TAPSE (69%), and S′ (31%) were commonly used in clinical routine. These methods were applied significantly less common in low-income economies when compared to high-income economies. Twenty-three percent of all participants stated to rely on eyeballing only, when evaluating RV function in clinical routine. New technologies, such as global longitudinal strain (3%) and 3D echocardiography (1%) were rarely applied independent of region and economic strength. Eyeballing and TAPSE are the most widely used methods in echocardiography for the assessment of RV function. Although advanced parameters such as longitudinal strain and 3D echocardiography were shown to be highly accurate, they are rarely used in clinical routine.
- 6 September 2018
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 35 (1) , 49-56
Open AccessEchocardiographic assessment of right ventricular function: current clinical practice
Echocardiographic evaluation of right ventricular (RV) function is a challenge due to the complex anatomy of the RV. Several transthoracic echocardiographic methods have been suggested for the quantification of RV function. However, many of the parameters are time consuming and need dedicated hardware and software. We suspected that the majority of the established markers are not used on a wide basis. In a multinational online survey, we evaluated the use of current clinical standards for the quantification of RV function in clinical practice. Through the network of an Ultrasound Online Teaching Platform, echocardiographers were invited to participate in an open online survey. The participants were asked about the parameters (eyeballing, TAPSE, S′, fractional area change, RIMP, 3D-EF, dp/dt, longitudinal strain) they used in clinical practice. A total of 1150 participants from 109 countries completed the survey. Only eyeballing (72%), TAPSE (69%), and S′ (31%) were commonly used in clinical routine. These methods were applied significantly less common in low-income economies when compared to high-income economies. Twenty-three percent of all participants stated to rely on eyeballing only, when evaluating RV function in clinical routine. New technologies, such as global longitudinal strain (3%) and 3D echocardiography (1%) were rarely applied independent of region and economic strength. Eyeballing and TAPSE are the most widely used methods in echocardiography for the assessment of RV function. Although advanced parameters such as longitudinal strain and 3D echocardiography were shown to be highly accurate, they are rarely used in clinical routine.
- 1 August 2018
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 39 (suppl_1)
P5635Visual assessment of right ventricular function in echocardiography: how good are we?
Background: The complex anatomy of the right ventricle complicates correct echocardiographic assessment of right ventricular systolic function by visual eyeballing.
- 1 August 2018
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 39 (suppl_1)
P5635Visual assessment of right ventricular function in echocardiography: how good are we?
Background: The complex anatomy of the right ventricle complicates correct echocardiographic assessment of right ventricular systolic function by visual eyeballing.
- 1 August 2018
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 39 (suppl_1)
P6302Normal values for doppler echocardiographic assessment of prosthetic valve function after TAVR - A systematic review and meta-analysis
Background: Transcatheter aortic valve replacement (TAVR) has emerged as an attractive, minimally invasive alternative to surgical AVR in patients at high and intermediate surgical risk. Particularities specific to TAVR and a rapidly growing number of available prosthesis make post-procedural assessment of valve function challenging. Aim of the present analysis was to collect and pool all available data cin the literature regarding normal doppler values for transcatheter prosthetic heart valves and to provide a comprehensive overview.
- 1 August 2018
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 39 (suppl_1)
P6302Normal values for doppler echocardiographic assessment of prosthetic valve function after TAVR - A systematic review and meta-analysis
Background: Transcatheter aortic valve replacement (TAVR) has emerged as an attractive, minimally invasive alternative to surgical AVR in patients at high and intermediate surgical risk. Particularities specific to TAVR and a rapidly growing number of available prosthesis make post-procedural assessment of valve function challenging. Aim of the present analysis was to collect and pool all available data cin the literature regarding normal doppler values for transcatheter prosthetic heart valves and to provide a comprehensive overview.
- Open Access
- 11 December 2017
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 34 (5) , 695-700
Multi-view approach for the diagnosis of pulmonary hypertension using transthoracic echocardiography
Pulmonary hypertension (PH) is a disease with severe morbidity and mortality. Echocardiography plays an essential role in the screening of PH. The quality of the acquired continuous wave Doppler signal is the major limitation of the method and can greatly affect the accuracy of estimated pulmonary pressures. The aim of this study was to evaluate the clinical need to image from multiple ultrasound windows in patients with suspected pulmonary hypertension. We prospectively evaluated 65 patients (43% male, mean age 67.2 years) with echocardiography and right heart catheterization. 17% had invasively normal pulmonary pressures, 83% had pulmonary hypertension. Peak tricuspid regurgitation (TR) velocity was imaged in five echocardiographic views. Sufficient Doppler signal was recorded in 94% of the patients. Correlation for overall peak TR velocity with invasively measured systolic pulmonary artery pressure was r = 0.83 (p < 0.001). Considering all five imaging windows resulted in a sensitivity of 87%, and a specificity of 91% for correct diagnosis of PH with an AUC of 0.89, which was significantly better as compared to sole imaging from the right ventricular modified apical four-chamber view (AUC 0.85, p = 0.0395). Additional imaging from atypical views changed the overall peak TR velocity in 32% of the patients. A multiple-view approach changed the echocardiographic diagnosis of PH in 11% of the patients as opposed to sole imaging from an apical four-chamber view. This study comprehensively assessed the impact on clinical decision making when evaluating patients with an echocardiographic multiplane approach for suspected PH. This approach substantially increased sensitivity without a decrease in specificity.
- 11 December 2017
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 34 (5) , 695-700
Open AccessMulti-view approach for the diagnosis of pulmonary hypertension using transthoracic echocardiography
Pulmonary hypertension (PH) is a disease with severe morbidity and mortality. Echocardiography plays an essential role in the screening of PH. The quality of the acquired continuous wave Doppler signal is the major limitation of the method and can greatly affect the accuracy of estimated pulmonary pressures. The aim of this study was to evaluate the clinical need to image from multiple ultrasound windows in patients with suspected pulmonary hypertension. We prospectively evaluated 65 patients (43% male, mean age 67.2 years) with echocardiography and right heart catheterization. 17% had invasively normal pulmonary pressures, 83% had pulmonary hypertension. Peak tricuspid regurgitation (TR) velocity was imaged in five echocardiographic views. Sufficient Doppler signal was recorded in 94% of the patients. Correlation for overall peak TR velocity with invasively measured systolic pulmonary artery pressure was r = 0.83 (p < 0.001). Considering all five imaging windows resulted in a sensitivity of 87%, and a specificity of 91% for correct diagnosis of PH with an AUC of 0.89, which was significantly better as compared to sole imaging from the right ventricular modified apical four-chamber view (AUC 0.85, p = 0.0395). Additional imaging from atypical views changed the overall peak TR velocity in 32% of the patients. A multiple-view approach changed the echocardiographic diagnosis of PH in 11% of the patients as opposed to sole imaging from an apical four-chamber view. This study comprehensively assessed the impact on clinical decision making when evaluating patients with an echocardiographic multiplane approach for suspected PH. This approach substantially increased sensitivity without a decrease in specificity.