Rui Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rui Tang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Hai Huang
School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ, USA
3 shared publicationsHongyu Yu
School of Electrical, Computer and Energy Engineering and School of Earth and Space Exploration, Arizona State University, Tempe, AZ, USA
3 shared publicationsJonathon Oiler
School of Earth and Space Exploration, Arizona State University, Tempe, AZ, USA
2 shared publicationsMengbing Liang
School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ, USA
2 shared publicationsRanran Liu
Louisiana State University
1 shared publicationShengmin Guo
Louisiana State University
1 shared publication
Latest Publications
- 28 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 34 (10) , 1304-1306
Molecular Electronic Transducer-Based Low-Frequency Accelerometer Fabricated With Post-CMOS Compatible Process Using Droplet as Sensing Body
This letter reports a low-frequency micro-accelerometer implementing a liquid-state sensing body, based on molecular electronic transducer (MET) in post-CMOS compatible microfabrication technology. The device employs a sub-microliter electrolyte droplet encapsulated in oil as the sensing body, and a MET electrode configuration as the sensing read-out mechanism. The promising and unique performance of the MET design allows the fabricated device to achieve 10.8 V/G(G=9.81 m/s2) sensitivity at 20 Hz with nearly flat response over the frequency range from 1 to 50 Hz, and a low noise floor of 75 μG/√(Hz) at 20 Hz.
- 28 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 34 (10) , 1304-1306
Molecular Electronic Transducer-Based Low-Frequency Accelerometer Fabricated With Post-CMOS Compatible Process Using Droplet as Sensing Body
This letter reports a low-frequency micro-accelerometer implementing a liquid-state sensing body, based on molecular electronic transducer (MET) in post-CMOS compatible microfabrication technology. The device employs a sub-microliter electrolyte droplet encapsulated in oil as the sensing body, and a MET electrode configuration as the sensing read-out mechanism. The promising and unique performance of the MET design allows the fabricated device to achieve 10.8 V/G(G=9.81 m/s2) sensitivity at 20 Hz with nearly flat response over the frequency range from 1 to 50 Hz, and a low noise floor of 75 μG/√(Hz) at 20 Hz.
- 29 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 13 (10) , 3991-3998
Three-Dimensional Flexible Thermal Sensor for Intravascular Flow Monitoring
A novel design and assembly technology is developed for a three-dimensional (3-D) flexible thermal flow sensor based on convective heat transfer to reduce detection error caused by position variation of a sensor inside the flow of narrow and curved geometries, such as coronary artery. The 3-D sensor has three independent sensing elements equally distributed around the catheter tube. This arrangement introduces three independent information channels, and cross-comparisons are used to provide accurate flow measurement. The resistance of the sensing elements is measured at ~ 1-1.2 kΩ with the temperature coefficient of resistance at 0.086%/°C. Using a constant-current circuit, the three sensing elements are heated to ~ 10°C above ambient temperature. Flow testing is implemented in a pipe channel at two positions: on the wall and along the center line. Experimental results from these two positions are discussed and computational fluid dynamic simulation based on Newtonian fluid properties is implemented, showing comparable results within an acceptable range of experimental to simulation errors. Therefore, we demonstrate the capability of 3-D thermal flow sensor for detecting the position of the catheter in the flow channel, thereby providing an accurate flow measurement.
- 29 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 13 (10) , 3991-3998
Three-Dimensional Flexible Thermal Sensor for Intravascular Flow Monitoring
A novel design and assembly technology is developed for a three-dimensional (3-D) flexible thermal flow sensor based on convective heat transfer to reduce detection error caused by position variation of a sensor inside the flow of narrow and curved geometries, such as coronary artery. The 3-D sensor has three independent sensing elements equally distributed around the catheter tube. This arrangement introduces three independent information channels, and cross-comparisons are used to provide accurate flow measurement. The resistance of the sensing elements is measured at ~ 1-1.2 kΩ with the temperature coefficient of resistance at 0.086%/°C. Using a constant-current circuit, the three sensing elements are heated to ~ 10°C above ambient temperature. Flow testing is implemented in a pipe channel at two positions: on the wall and along the center line. Experimental results from these two positions are discussed and computational fluid dynamic simulation based on Newtonian fluid properties is implemented, showing comparable results within an acceptable range of experimental to simulation errors. Therefore, we demonstrate the capability of 3-D thermal flow sensor for detecting the position of the catheter in the flow channel, thereby providing an accurate flow measurement.
- 29 April 2012
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 23 (12) , 2140-2144
A micro initiator realized by reactive Ni/Al nanolaminates
- 29 April 2012
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 23 (12) , 2140-2144
A micro initiator realized by reactive Ni/Al nanolaminates