Ewa Klimiec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ewa Klimiec has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Zaraska
Łukasiewicz Research Network—Institute of Microelectronics and Photonics, Kraków Division, ul. Zabłocie 39, 30-701 Kraków, Poland
7 shared publications Wiesław Zaraska
7 shared publications- Halina Kaczmarek
Faculty of Chemistry, Nicolaus Copernicus University in Toruń, Gagarina 7, 87-100 Toruń, Poland
5 shared publications - Jacek Piekarski
Institute of Electron Technology Cracow Division
5 shared publications - Bogusław Królikowski
Institute for Engineering of Polymer Materials and Dyes – Toruń Division, Toruń, Poland
4 shared publications - Piotr Guzdek
Department of Microelectronics, Institute of Electron Technology, Kraków. Poland
4 shared publications
Latest Publications
- Open Access
Investigation of Impact of Walking Speed on Forces Acting on a Foot–Ground Unit
Static and dynamic methods can be used to assess the way a foot is loaded. The research question is how the pressure on the feet would vary depending on walking/running speed. This study involved 20 healthy volunteers. Dynamic measurement of foot pressure was performed using the Ortopiezometr at normal, slow, and fast paces of walking. Obtained data underwent analysis in a “Steps” program. Based on the median, the power generated by the sensors during the entire stride period is the highest during a fast walk, whereas based on the average; a walk or slow walk prevails. During a fast walk, the difference between the mean and the median of the stride period is the smallest. Regardless of the pace of gait, the energy released per unit time does not depend on the paces of the volunteers’ gaits. Conclusions: Ortopiezometr is a feasible tool for the dynamic measurement of foot pressure. For investigations on walking motions, the plantar pressure analysis system, which uses the power generated on sensors installed in the insoles of shoes, is an alternative to force or energy measurements. Regardless of the pace of the walk, the amounts of pressure applied to the foot during step are similar among healthy volunteers.
Open AccessInvestigation of Impact of Walking Speed on Forces Acting on a Foot–Ground Unit
Static and dynamic methods can be used to assess the way a foot is loaded. The research question is how the pressure on the feet would vary depending on walking/running speed. This study involved 20 healthy volunteers. Dynamic measurement of foot pressure was performed using the Ortopiezometr at normal, slow, and fast paces of walking. Obtained data underwent analysis in a “Steps” program. Based on the median, the power generated by the sensors during the entire stride period is the highest during a fast walk, whereas based on the average; a walk or slow walk prevails. During a fast walk, the difference between the mean and the median of the stride period is the smallest. Regardless of the pace of gait, the energy released per unit time does not depend on the paces of the volunteers’ gaits. Conclusions: Ortopiezometr is a feasible tool for the dynamic measurement of foot pressure. For investigations on walking motions, the plantar pressure analysis system, which uses the power generated on sensors installed in the insoles of shoes, is an alternative to force or energy measurements. Regardless of the pace of the walk, the amounts of pressure applied to the foot during step are similar among healthy volunteers.
- Open Access
Corona Charging of Isotactic-Polypropylene Composites
A new approach to obtaining piezoelectric polymeric films based on the isotactic-polypropylene (i-PP) using corona discharge with the energy of 45 W·min/m2 was presented. Detailed analyses with Atomic Force Microscopy (AFM) led to the conclusion that the surface quality was the important factor influencing the possibility of charging the i-PP composites, which was necessary to induce the permanent piezoelectric effect. It has been found that the high surface smoothness of the polymer films contributed to improved piezoelectric properties without the need for an additional polymer modification such as orientation, foaming or doping with fillers. The values of the piezoelectric constant, d33, of the studied samples were compared to these values for the analogous systems polarized with a constant electric field of 100 V/μm. The milder conditions of the film polarization during the corona discharge process are sufficient to achieve the electrets in i-PP films. The simple and cheap method proposed can be profitable in obtaining flexible electrets in the form of thin films for the production of personal biomedical sensors.
Open AccessCorona Charging of Isotactic-Polypropylene Composites
A new approach to obtaining piezoelectric polymeric films based on the isotactic-polypropylene (i-PP) using corona discharge with the energy of 45 W·min/m2 was presented. Detailed analyses with Atomic Force Microscopy (AFM) led to the conclusion that the surface quality was the important factor influencing the possibility of charging the i-PP composites, which was necessary to induce the permanent piezoelectric effect. It has been found that the high surface smoothness of the polymer films contributed to improved piezoelectric properties without the need for an additional polymer modification such as orientation, foaming or doping with fillers. The values of the piezoelectric constant, d33, of the studied samples were compared to these values for the analogous systems polarized with a constant electric field of 100 V/μm. The milder conditions of the film polarization during the corona discharge process are sufficient to achieve the electrets in i-PP films. The simple and cheap method proposed can be profitable in obtaining flexible electrets in the form of thin films for the production of personal biomedical sensors.
- Open Access
Cellular Polyolefin Composites as Piezoelectric Materials: Properties and Applications
Piezoelectric polymers characterized by flexibility are sought for applications in microelectronics, medicine, telecommunications, and everyday devices. The objective of this work was to obtain piezoelectric polymeric composites with a cellular structure and to evaluate their usefulness in practice. Composites based on polyolefins (isotactic-polypropylene and polyethylene) with the addition of aluminosilicate fillers were manufactured by extrusion, and then polarized in a constant electric field at 100 V/µm. The content of mineral fillers up to 10 wt% in the polymer matrix enhances its electric stability and mechanical strength. The value of the piezoelectric coefficient d33 attained ~150 pC/N in the range of lower stresses and ~80 pC/N in the range of higher stresses, i.e., at ~120 kPa. The materials exhibited high durability in time, therefore, they can be used as transducers of mechanical energy of the human motion into electric energy. It was demonstrated that one shoe insert generates an energy of 1.1 mJ after a person walks for 300 s. The miniaturized integrated circuits based on polyolefin composites may be applied for the power supply of portable electronics. Due to their high sensitivity, they can be recommended for measuring the blood pulse.
Open AccessCellular Polyolefin Composites as Piezoelectric Materials: Properties and Applications
Piezoelectric polymers characterized by flexibility are sought for applications in microelectronics, medicine, telecommunications, and everyday devices. The objective of this work was to obtain piezoelectric polymeric composites with a cellular structure and to evaluate their usefulness in practice. Composites based on polyolefins (isotactic-polypropylene and polyethylene) with the addition of aluminosilicate fillers were manufactured by extrusion, and then polarized in a constant electric field at 100 V/µm. The content of mineral fillers up to 10 wt% in the polymer matrix enhances its electric stability and mechanical strength. The value of the piezoelectric coefficient d33 attained ~150 pC/N in the range of lower stresses and ~80 pC/N in the range of higher stresses, i.e., at ~120 kPa. The materials exhibited high durability in time, therefore, they can be used as transducers of mechanical energy of the human motion into electric energy. It was demonstrated that one shoe insert generates an energy of 1.1 mJ after a person walks for 300 s. The miniaturized integrated circuits based on polyolefin composites may be applied for the power supply of portable electronics. Due to their high sensitivity, they can be recommended for measuring the blood pulse.
- Open Access
Piezoelectric Films Based on Polyethylene Modified by Aluminosilicate Filler
The development, universality and miniaturization of electronic devices leads to the search for new piezoelectric materials, among which recently, polymers play an increasingly important role. In this work, composites based on two types of polyethylene—high density polyethylene (HDPE), and medium density polyethylene (MDPE)—and aluminosilicate fillers were obtained by extrusion process. This method allowed obtaining flexible electrets in the form of a thin film after polarization under a constant electric field of 100 V/μm. The morphology of the composites was characterized by scanning electron microscopy, whereas the crystallinity was determined by X-ray diffraction. The mechanical properties and thermal stability of the composites were examined by means of tensile tests and thermogravimetry, respectively. The piezoelectric characteristics were appointed by measuring the electric charge and the voltage in the polarized samples. Piezoelectric coefficients, and the stability of electrets over time were also determined. Moreover, the effect of film orientation on piezoelectric properties was investigated. Composites with appropriate morphology (i.e., well dispersed filler particles in the polymer matrix and formed holes) were obtained which ensured permanent electrical polarization. It was found that the best piezoelectric, mechanical properties and thermal stability exhibits HDPE composite with 5% of aluminosilicate filler.
Open AccessPiezoelectric Films Based on Polyethylene Modified by Aluminosilicate Filler
The development, universality and miniaturization of electronic devices leads to the search for new piezoelectric materials, among which recently, polymers play an increasingly important role. In this work, composites based on two types of polyethylene—high density polyethylene (HDPE), and medium density polyethylene (MDPE)—and aluminosilicate fillers were obtained by extrusion process. This method allowed obtaining flexible electrets in the form of a thin film after polarization under a constant electric field of 100 V/μm. The morphology of the composites was characterized by scanning electron microscopy, whereas the crystallinity was determined by X-ray diffraction. The mechanical properties and thermal stability of the composites were examined by means of tensile tests and thermogravimetry, respectively. The piezoelectric characteristics were appointed by measuring the electric charge and the voltage in the polarized samples. Piezoelectric coefficients, and the stability of electrets over time were also determined. Moreover, the effect of film orientation on piezoelectric properties was investigated. Composites with appropriate morphology (i.e., well dispersed filler particles in the polymer matrix and formed holes) were obtained which ensured permanent electrical polarization. It was found that the best piezoelectric, mechanical properties and thermal stability exhibits HDPE composite with 5% of aluminosilicate filler.
- Open Access
- 24 July 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 28 (22) , 16639-16647
Characterization of piezoelectric films of foamed polyethylene obtained by extrusion
- 24 July 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 28 (22) , 16639-16647
Open AccessCharacterization of piezoelectric films of foamed polyethylene obtained by extrusion
- 15 March 2017
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (5) , 054008
Measuring of foot plantar pressure—possible applications in quantitative analysis of human body mobility
The paper presents an evaluation of human mobility by gait analysis, carried out in natural conditions (outside of the laboratory). Foot plantar pressure is measured using a shoe insole with 8 sensors placed in different anatomical zones of the foot, and placed inside a sports shoe. Polarized polyvinylidene fluoride (PVDF) foil is used as a sensor material. A wireless transmission system is used to transmit voltage values to the computer. Miniaturization was the priority during the design of the system. Due to the linear relationship between force and transducer voltage, energy and power released during walking in arbitrary units can be calculated as an integral of the square of the transducer voltage over time. Gait measurements were carried out over several days on healthy persons during normal walking and slow walking. The performed measurements allowed for the determination of walking speed (number of steps per second), gait rhythm and manner of walking (applying force to inside versus outside part of the sole). It was found that switching from normal to slow walk increases gait energy by 25% while the pressure distribution across the anatomical regions of the foot remains unchanged. The results will be used to develop a programme for the evaluation of patients with orthopedic diseases or even with cardiac failures, for an estimation of the results of health recovery and training efficiency in many sports activities.
- 15 March 2017
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (5) , 054008
Measuring of foot plantar pressure—possible applications in quantitative analysis of human body mobility
The paper presents an evaluation of human mobility by gait analysis, carried out in natural conditions (outside of the laboratory). Foot plantar pressure is measured using a shoe insole with 8 sensors placed in different anatomical zones of the foot, and placed inside a sports shoe. Polarized polyvinylidene fluoride (PVDF) foil is used as a sensor material. A wireless transmission system is used to transmit voltage values to the computer. Miniaturization was the priority during the design of the system. Due to the linear relationship between force and transducer voltage, energy and power released during walking in arbitrary units can be calculated as an integral of the square of the transducer voltage over time. Gait measurements were carried out over several days on healthy persons during normal walking and slow walking. The performed measurements allowed for the determination of walking speed (number of steps per second), gait rhythm and manner of walking (applying force to inside versus outside part of the sole). It was found that switching from normal to slow walk increases gait energy by 25% while the pressure distribution across the anatomical regions of the foot remains unchanged. The results will be used to develop a programme for the evaluation of patients with orthopedic diseases or even with cardiac failures, for an estimation of the results of health recovery and training efficiency in many sports activities.
- Open Access
- 13 January 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 28 (9) , 6435-6447
New piezoelectric composites based on isotactic polypropylene filled with silicate
- 13 January 2017
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 28 (9) , 6435-6447
Open AccessNew piezoelectric composites based on isotactic polypropylene filled with silicate
- 10 November 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10161, 1016110-1016110-11
Application of a system for measuring foot plantar pressure for evaluation of human mobility
- 10 November 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10161, 1016110-1016110-11
Application of a system for measuring foot plantar pressure for evaluation of human mobility
- 1 August 2016
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 247, 504-513
Durable sensors for measurement of foot plantar pressure with piezoelectric polyvinylidene fluoride foil
- 1 August 2016
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 247, 504-513
Durable sensors for measurement of foot plantar pressure with piezoelectric polyvinylidene fluoride foil
- 24 March 2015
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 44 (7) , 2283-2291
Increase of Piezoelectric Constant and Thermal Durability of Polypropylene Electret by Introducing SiO2 and Kaolin Filler and Creating a Cellular Structure
- 24 March 2015
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 44 (7) , 2283-2291
Increase of Piezoelectric Constant and Thermal Durability of Polypropylene Electret by Introducing SiO2 and Kaolin Filler and Creating a Cellular Structure