DCDaniel James Cziczo

Daniel James Cziczo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniel James Cziczo has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantifying and improving the optical performance of the laser ablation aerosol particle time of flight mass spectrometer (LAAPToF) instrument

    by Maria A. Zawadowicz, Sara Lance, John T. Jayne, Philip Croteau, Douglas R. Worsnop, Fabian Mahrt, Thomas Leisner, Daniel J. Cziczo

    Single particle mass spectrometer (SPMS) instruments have been used for in-situ chemical characterization of atmospheric aerosols, both in the field and laboratory, for over two decades. SPMSs typically combine precise optical particle sizing with laser desorption and ionization followed by time of flight mass spectrometry. Among the advantages of SPMSs over other aerosol chemistry measurement techniques are their single particle resolution and high sensitivity to trace chemical species. The AeroMegt Laser Ablation Aerosol Particle Time of Flight Mass Spectrometer (LAAPToF) is a commercially available member of this instrument class, aiming for a compact size and simplicity for the end user. This paper quantifies the performance of LAAPToF with an emphasis on optical counting efficiency. Recommendations for improving detection compared to the base LAAPToF hardware are described. Our results show that changes to the optical detection scheme can lead to over two orders of magnitude improvement in optical counting efficiency in the size range 500-2000 nm vacuum aerodynamic diameter. We also present mass spectral performance for characterizing atmospherically-relevant particles in a comparison to a current SPMS design, the Particle Analysis by Laser Mass Spectrometry. Copyright © 2020 American Association for Aerosol Research


  • Open Access

    Model-measurement consistency and limits of bioaerosol abundance over the continental United States

    by Maria A. Zawadowicz, Karl D. Froyd, Anne E. Perring, Daniel M. Murphy, Dominick V. Spracklen, Colette L. Heald, Peter R. Buseck, Daniel J. Cziczo

    Due to low concentrations and chemical complexity, in situ observations of bioaerosol are geographically and temporally sparse, and this limits the accuracy of current emissions inventories. In this study, we apply a new methodology, including corrections for misidentification of mineral dust, to measurements of single particles over four airborne sampling campaigns to derive vertical profiles of bioaerosol over the continental United States. The new methodology is based on single-particle mass spectrometry (SPMS); it can extend historic datasets to include measurements of bioaerosol, it allows comparisons to other techniques, and it generally agrees with a global aerosol model. In the locations sampled, bioaerosols were at least a factor of 10 less abundant than mineral dust. Below 2 km, bioaerosol concentrations were measured between 6×103 and 2×104 m−3. Between 2 and 8 km, bioaerosol concentrations were between 0 and 2×104 m−3, and above 8 km, bioaerosol concentrations were between 0 and 1×103 m−3. Between 30 % and 80 % of single bioaerosol particles detected were internally mixed with dust. A direct comparison of the SPMS methodology with a co-located wideband integrated bioaerosol sensor (WIB) fluorescence sensor on a mountaintop site showed agreement to within a factor of 3 over the common size range.


  • Open Access

    A machine learning approach to aerosol classification for single-particle mass spectrometry

    by Costa D. Christopoulos, Sarvesh Garimella, Maria A. Zawadowicz, Ottmar Möhler, Daniel J. Cziczo

    Compositional analysis of atmospheric and laboratory aerosols is often conducted via single-particle mass spectrometry (SPMS), an in situ and real-time analytical technique that produces mass spectra on a single-particle basis. In this study, classifiers are created using a data set of SPMS spectra to automatically differentiate particles on the basis of chemistry and size. Machine learning algorithms build a predictive model from a training set for which the aerosol type associated with each mass spectrum is known a priori. Our primary focus surrounds the growing of random forests using feature selection to reduce dimensionality and the evaluation of trained models with confusion matrices. In addition to classifying ∼20 unique, but chemically similar, aerosol types, models were also created to differentiate aerosol within four broader categories: fertile soils, mineral/metallic particles, biological particles, and all other aerosols. Differentiation was accomplished using ∼40 positive and negative spectral features. For the broad categorization, machine learning resulted in a classification accuracy of ∼93 %. Classification of aerosols by specific type resulted in a classification accuracy of ∼87 %. The “trained” model was then applied to a “blind” mixture of aerosols which was known to be a subset of the training set. Model agreement was found on the presence of secondary organic aerosol, coated and uncoated mineral dust, and fertile soil.


  • Open Access

    A continuous flow diffusion chamber study of sea salt particles acting as cloud nuclei: deliquescence and ice nucleation

    by Xiangrui Kong, Martin J. Wolf, Michael Roesch, Erik S. Thomson, Thorsten Bartels-Rausch, Peter A. Alpert, Markus Ammann, Nønne L. Prisle, Daniel J. Cziczo

    Phase changes of sea salt particles alter their physical and chemical properties, which is significant for Earth’s chemistry and energy budget. In this study, a continuous flow diffusion chamber is used to investigate deliquescence, homogeneous and heterogeneous ice nucleation between 242 K and 215 K, of four salts: pure NaCl, pure MgCl2, synthetic sea water salt, and salt distilled from sampled sea water. Anhydrous particles, aqueous droplets and ice particles were discriminated using a polarisation-sensitive optical particle counter coupled with a machine learning analysis technique. The measured onset deliquescence relative humidities agree with previous studies, where sea water salts deliquescence at lower humidities than pure NaCl. Deliquesced salt droplets homogenously freeze when the relative humidity reaches a sufficiently high value at temperatures below 233 K. From 224 K and below, deposition nucleation freezing on a fraction of NaCl particles was observed at humidities lower than the deliquescence relative humidity. At these low temperatures, otherwise unactivated salt particles deliquesced at the expected deliquescence point, followed by homogeneous freezing at temperatures as low as 215 K. Thus, the observed sea salt particles exhibit a triad of temperature-dependent behaviours. First, they act as cloud condensation particles (CCNs) > 233 K, second they can be homogeneous freezing nuclei (HFNs) < 233 K and finally they act as ice nucleating particles (INPs) for heterogeneous nucleation <224 K.


  • Open Access

    How Uncertainty in Field Measurements of Ice Nucleating Particles Influences Modeled Cloud Forcing

    by S. Garimella, D. A. Rothenberg, M. J. Wolf, C. Wang, D. J. Cziczo

    Field and laboratory measurements using continuous flow diffusion chambers (CFDCs) have been used to construct parameterizations of the number of ice nucleating particles (INPs) in mixed-phase and completely glaciated clouds in weather and climate models. Because of flow nonidealities, CFDC measurements are subject to systematic low biases. Here, the authors investigate the effects of this undercounting bias on simulated cloud forcing in a global climate model. The authors assess the influence of measurement variability by constructing a stochastic parameterization framework to endogenize measurement uncertainty. The authors find that simulated anthropogenic longwave ice-bearing cloud forcing in a global climate model can vary up to 0.8 W m−2and can change sign from positive to negative within the experimentally constrained bias range. Considering the variability in the undercounting bias, in a range consistent with recent experiments, leads to a larger negative cloud forcing than that when the variability is ignored and only a constant bias is assumed.


  • Open Access

    Real-time analysis of insoluble particles in glacial ice using single-particle mass spectrometry

    by Matthew Osman, Maria A. Zawadowicz, Sarah B. Das, Daniel J. Cziczo

    Insoluble aerosol particles trapped in glacial ice provide insight into past climates, but analysis requires information on climatically relevant particle properties, such as size, abundance, and internal mixing. We present a new analytical method using a time-of-flight single-particle mass spectrometer (SPMS) to determine the composition and size of insoluble particles in glacial ice over an aerodynamic size range of ∼ 0.2–3.0 µm diameter. Using samples from two Greenland ice cores, we developed a procedure to nebulize insoluble particles suspended in melted ice, evaporate condensed liquid from those particles, and transport them to the SPMS for analysis. We further determined size-dependent extraction and instrument transmission efficiencies to investigate the feasibility of determining particle-class-specific mass concentrations. We find SPMS can be used to provide constraints on the aerodynamic size, composition, and relative abundance of most insoluble particulate classes in ice core samples. We describe the importance of post-aqueous processing to particles, a process which occurs due to nebulization of aerosols from an aqueous suspension of originally soluble and insoluble aerosol components. This study represents an initial attempt to use SPMS as an emerging technique for the study of insoluble particulates in ice cores.


  • Open Access

    Uncertainty in counting ice nucleating particles with continuous flow diffusion chambers

    by Sarvesh Garimella, Daniel A. Rothenberg, Martin J. Wolf, Robert O. David, Zamin A. Kanji, Chien Wang, Michael Rösch, Daniel J. Cziczo

    This study investigates the measurement of ice nucleating particle (INP) concentrations and sizing of crystals using continuous flow diffusion chambers (CFDCs). CFDCs have been deployed for decades to measure the formation of INPs under controlled humidity and temperature conditions in laboratory studies and by ambient aerosol populations. These measurements have, in turn, been used to construct parameterizations for use in models by relating the formation of ice crystals to state variables such as temperature and humidity as well as aerosol particle properties such as composition and number. We show here that assumptions of ideal instrument behavior are not supported by measurements made with a commercially available CFDC, the SPectrometer for Ice Nucleation (SPIN), and the instrument on which it is based, the Zurich Ice Nucleation Chamber (ZINC). Non-ideal instrument behavior, which is likely inherent to varying degrees in all CFDCs, is caused by exposure of particles to different humidities and/or temperatures than predicated from instrument theory of operation. This can result in a systematic, and variable, underestimation of reported INP concentrations. We find here variable correction factors from 1.5 to 9.5, consistent with previous literature values. We use a machine learning approach to show that non-ideality is most likely due to small-scale flow features where the aerosols are combined with sheath flows. Machine learning is also used to minimize the uncertainty in measured INP concentrations. We suggest that detailed measurement, on an instrument-by-instrument basis, be performed to characterize this uncertainty.


  • Open Access

    Real time analysis of insoluble particles in glacial ice using single particle mass spectrometry

    by Matthew Osman, Maria A. Zawadowicz, Sarah B. Das, Daniel J. Cziczo

    Insoluble aerosol particles trapped in glacial ice provide insight into past climates, but analysis requires information on climatically-relevant particle properties, such as size, abundance, and internal mixing. We present a new analytical method using a time-of-flight single particle mass spectrometer (SPMS) to determine the composition and size of insoluble particles in glacial ice over an aerodynamic size range of ~ 0.2–3.0 µm diameter. Using samples from two Greenland ice cores, we developed a procedure to nebulize insoluble particles suspended in melted ice, evaporate condensed liquid from those particles, and transport them to the SPMS for analysis. We further determined size-dependent extraction and instrument transmission efficiencies to investigate particle-class specific mass concentrations. We find SPMS can be used to provide constraints on the aerodynamic size, composition, and relative abundance of most insoluble particulate classes in ice core samples. We describe the importance of post-aqueous processing to particles, a process which occurs due to nebulization of aerosols from an aqueous suspension of originally soluble and insoluble aerosol components. This study represents an initial attempt to use SPMS as an emerging technique for the study of insoluble particulates in ice cores.


  • Open Access

    Improved identification of primary biological aerosol particles using single-particle mass spectrometry

    by Maria A. Zawadowicz, Karl D. Froyd, Daniel M. Murphy, Daniel J. Cziczo

    Measurements of primary biological aerosol particles (PBAP), especially at altitudes relevant to cloud formation, are scarce. Single-particle mass spectrometry (SPMS) has been used to probe aerosol chemical composition from ground and aircraft for over 20 years. Here we develop a method for identifying bioaerosols (PBAP and particles containing fragments of PBAP as part of an internal mixture) using SPMS. We show that identification of bioaerosol using SPMS is complicated because phosphorus-bearing mineral dust and phosphorus-rich combustion by-products such as fly ash produce mass spectra with peaks similar to those typically used as markers for bioaerosol. We have developed a methodology to differentiate and identify bioaerosol using machine learning statistical techniques applied to mass spectra of known particle types. This improved method provides far fewer false positives compared to approaches reported in the literature. The new method was then applied to two sets of ambient data collected at Storm Peak Laboratory and a forested site in Central Valley, California to show that 0.04–2 % of particles in the 200–3000 nm aerodynamic diameter range were identified as bioaerosol. In addition, 36–56 % of particles identified as biological also contained spectral features consistent with mineral dust, suggesting internal dust–biological mixtures.


  • Open Access

    Uncertainty in counting ice nucleating particles with continuous diffusion flow chambers

    by Sarvesh Garimella, Daniel A. Rothenberg, Martin J. Wolf, Robert O. David, Zamin A. Kanji, Chien Wang, Michael Roesch, Daniel J. Cziczo

    This study investigates the measurement of ice nucleating particle (INP) concentration and sizing of crystals using continuous flow diffusion chambers (CFDCs). CFDCs have been deployed for decades to measure the formation of INPs under controlled humidity and temperature conditions in laboratory studies and by ambient aerosol populations. These measurements have, in turn, been used to construct parameterizations for use in models by relating the formation of ice crystals to state variables such as temperature, humidity, and aerosol particle properties such as composition and number. We show here that assumptions of ideal instrument behavior are not supported by measurements made with a commercially available CFDC, the SPectrometer for Ice Nucleation (SPIN), and the instrument on which it is based, the Zurich Ice Nucleation Chamber (ZINC). Non-ideal instrument behavior, which is likely inherent to varying degrees in all CFDCs, is caused by exposure of particles to different humidities and/or temperatures than predicated from theory. This can result in a systematic, and variable, underestimation of reported INP concentrations. We use a machine learning approach to show that non-ideality is most likely due to small scale flow features where the aerosols are combined with sheath flows and to minimize the uncertainty associated with measured INP concentrations. We suggest that detailed measurement, on an instrument-by-instrument basis, be performed to characterize this uncertainty.