JWJacob A. Warner

Jacob A. Warner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jacob A. Warner has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Bruce Forsyth

    Boston Scientific Corporation, Maple Grove, Minnesota, 55341

    1 shared publication
  • Chris Frethem

    Characterization Facility, University of Minnesota, Minneapolis, Minnesota, 55455

    1 shared publication
  • Fang Zhou

    Characterization Facility, University of Minnesota, Minneapolis, Minnesota, 55455

    1 shared publication
  • Greg Haugstad

    Characterization Facility, University of Minnesota, Minneapolis, Minnesota, 55455

    1 shared publication
  • Heiko Timmers

    University of New South Wales

    1 shared publication
  • Jason Myers

    Characterization Facility, University of Minnesota, Minneapolis, Minnesota, 55455

    1 shared publication

Latest Publications

  • Characterization of Pebax angioplasty balloon surfaces with AFM, SEM, TEM, and SAXS

    by Jacob A. Warner, Bruce Forsyth, Fang Zhou, Jason Myers, Chris Frethem, Greg Haugstad

    In the medical device industry, angioplasty balloons have been widely used in the less invasive treatment of heart disease by expanding and relieving clogged structures in various arterial segments. However, new applications using thin coatings on the balloon surface have been explored to enhance therapeutic value in the delivery of pharmaceuticals (drug‐elution) or control thermal energy output (RF ablation). In this study, angioplasty balloon materials comprised of poly(ether‐block‐amide) (Pebax) were investigated via atomic force microscopy (AFM), transmission electron microscopy (TEM), scanning electron microscopy (SEM), and small‐angle X‐ray scattering (SAXS) to characterize physical properties at the balloon surface that may affect coating adhesion. The soft segment of this Pebax 1074 material is polyethylene oxide (PEO) and the hard segment is nylon‐12. The morphology of the hard segments of this block co‐polymer are found via AFM stiffness measurements to be (40 ± 20) nm by (300 ± 150) nm and are oriented parallel to the surface of the balloon. SAXS measurements found the lamellar spacing to be (18.5 ± 0.5) nm, and demonstrate a preferential orientation in agreement with TEM and AFM measurements. Fixation of this balloon in resin, followed by cryo‐sectioning is shown to provide a novel manner in which to investigate surface characteristics on the balloon such as material or coating thickness as well as uniformity in comparison to the bulk structure. These outputs were deemed critical to improve overall balloon processing such as molding and surface treatment options for robust designs toward better procedural outcomes targeting new therapeutic areas. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 470–475, 2016.


  • Demonstration of a New Technique Using Radioisotope Tracers to Measure the Backside Wear Rate on Tibial Inserts

    by Jacob A. Warner, Laura G. Gladkis, Paul N. Smith, Jennifer M. Scarvell, Heiko Timmers