Reni Desmiarti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Reni Desmiarti has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Fusheng Li
Gifu Univ, River Basin Res Ctr, 1-1 Yanagido, Gifu 5011193, Japan
5 shared publications- Ariadi Hazmi
Electrical Engineering Department, Andalas University, 25166, Padang, Indonesia
4 shared publications Munas Martynis
Bung Hatta Univ, Fac Ind Technol, Dept Chem Engn, Padang 25147, Indonesia
3 shared publicationsToshiro Yamada
Gifu Univ, Fac Engn, Dept Civil Engn, 1-1 Yanagido, Gifu 5011193, Japan
2 shared publicationsYenni Trianda
Bung Hatta Univ, Fac Ind Technol, Dept Chem Engn, Padang 25147, Indonesia
2 shared publicationsA Hazmi
Electrical Engineering Department, Andalas University, 25166, Padang, Indonesia
1 shared publication
Latest Publications
- Open Access
- 9 December 2019
- Published by International Journal of Technology in International Journal of Technology
- Vol. 10 (8) , 1488-1497
Phenol Adsorption in Water by Granular Activated Carbon from Coconut Shell
Phenol adsorption by granular activated carbon from coconut shell was studied in batch experiments under various initial phenol concentrations. Adsorption equilibrium was reached within 4 hours. The characteristics of the phenol adsorption process onto granular activated carbon from coconut shell were studied by adsorption isotherm modeling, analysis that uses fluorescence spectroscopy, in addition to measuring nanoparticle size and volume distribution by a Zetasizer Nano. The Langmuir isotherm model best fits the phenol adsorption onto granular activated carbon from coconut shell, and the maximum adsorption capacities for unsterilized and sterilized types were found to be 17.54 mg/g and 13.70 mg/g, respectively. The excitation-emission matrix results showed that the humic-like substance’s peaks almost completely disappear post-adsorption. It was also found that the nanoparticle size distribution shifted from ranges of 0.72–1.74 nm in raw water to 45.66–726.73 nm and 57.08–1068.47 nm post-adsorption in unsterilized and sterilized water samples, respectively, suggesting that phenol adsorption had occurred. This study shows that low-cost coconut shell–based activated carbon demonstrated good removal capability and hence can be used as a new adsorbent material on large scale.
- 9 December 2019
- Published by International Journal of Technology in International Journal of Technology
- Vol. 10 (8) , 1488-1497
Open AccessPhenol Adsorption in Water by Granular Activated Carbon from Coconut Shell
Phenol adsorption by granular activated carbon from coconut shell was studied in batch experiments under various initial phenol concentrations. Adsorption equilibrium was reached within 4 hours. The characteristics of the phenol adsorption process onto granular activated carbon from coconut shell were studied by adsorption isotherm modeling, analysis that uses fluorescence spectroscopy, in addition to measuring nanoparticle size and volume distribution by a Zetasizer Nano. The Langmuir isotherm model best fits the phenol adsorption onto granular activated carbon from coconut shell, and the maximum adsorption capacities for unsterilized and sterilized types were found to be 17.54 mg/g and 13.70 mg/g, respectively. The excitation-emission matrix results showed that the humic-like substance’s peaks almost completely disappear post-adsorption. It was also found that the nanoparticle size distribution shifted from ranges of 0.72–1.74 nm in raw water to 45.66–726.73 nm and 57.08–1068.47 nm post-adsorption in unsterilized and sterilized water samples, respectively, suggesting that phenol adsorption had occurred. This study shows that low-cost coconut shell–based activated carbon demonstrated good removal capability and hence can be used as a new adsorbent material on large scale.
- Open Access
- 1 June 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 543 (1) , 012093
Study of Nanoparticle Distribution in Water Treated with Combined Filtration-Inductively Coupled Plasma System
Nanoparticles represent a specific type of organic or inorganic matter with at least one dimension less than 100 nm and possess unique physical and chemical properties. The presence of nanoparticles in drinking water may pose a direct human health threat or an indirect risk through ingestion. Thus, the removal of nanoparticles from drinking water is needed. This research was carried out to study the distribution of nanoparticles in water treated with a combined filtration-inductively coupled plasma system by continuous processing. The flow rate was set at 100 and 200 mL/minute. The results showed that after 180 minutes of treatment, the amount and volume of nanoparticles in the treated water produced were different from those contained in raw water. The nanoparticles were within the diameter ranges from 2.70 to 6.50 nm and 0.62 to 712 nm for flow rate at 100 and 150 mL/minute, respectively. The particles within these diameter ranges belong to the group of proteins, small molecules and atoms. The measured zeta potential of the treated water had also decreased, indicating that the stability of the nanoparticles was reduced and removal by the combined filtration-inductively coupled plasma system had occurred. Further research is required to find the optimum flow rate and determine the exact components of the groups of nanoparticles.
- 1 June 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 543 (1) , 012093
Open AccessStudy of Nanoparticle Distribution in Water Treated with Combined Filtration-Inductively Coupled Plasma System
Nanoparticles represent a specific type of organic or inorganic matter with at least one dimension less than 100 nm and possess unique physical and chemical properties. The presence of nanoparticles in drinking water may pose a direct human health threat or an indirect risk through ingestion. Thus, the removal of nanoparticles from drinking water is needed. This research was carried out to study the distribution of nanoparticles in water treated with a combined filtration-inductively coupled plasma system by continuous processing. The flow rate was set at 100 and 200 mL/minute. The results showed that after 180 minutes of treatment, the amount and volume of nanoparticles in the treated water produced were different from those contained in raw water. The nanoparticles were within the diameter ranges from 2.70 to 6.50 nm and 0.62 to 712 nm for flow rate at 100 and 150 mL/minute, respectively. The particles within these diameter ranges belong to the group of proteins, small molecules and atoms. The measured zeta potential of the treated water had also decreased, indicating that the stability of the nanoparticles was reduced and removal by the combined filtration-inductively coupled plasma system had occurred. Further research is required to find the optimum flow rate and determine the exact components of the groups of nanoparticles.
- Open Access
- 14 March 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 156, 03039
Characteristics of Nanoparticles in Drinking Water Treatment using Biological Activated Carbon
Characteristics of nanoparticles in drinking water treatment were performed using five types of biological activated carbon (BAC) columns (BAC1-BAC5) in continuous flow experiments. The BAC was created by covering granular activated carbon (GAC) with attached microorganisms from water samples taken from the Nagara River in Japan. The total running time was about 2000 h. The characteristics of the nanoparticles were investigated based on size distribution and volume distribution measured by Zetasizer Nano. Total dissolved organic carbon (DOC) and ultraviolet absorbance at 260 nm (UV260) were also studied. The important results in this study were that the detached nanoparticles in the effluent were within the size distribution ranges of 0.26~5.62 nm, 0.62~3.62 nm, 0.62~3.12 nm, 0.62~4.19 nm, and 0.62~6.50 for BAC 1, 2, 3, 4 and 5, respectively. The profile of peak size and peak number along the bed depth of the BAC columns was evaluated for better understanding the characteristics of the nanoparticles. This result is very important for improving drinking water treatment using granular activated carbon to remove microorganisms.
- 14 March 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 156, 03039
Open AccessCharacteristics of Nanoparticles in Drinking Water Treatment using Biological Activated Carbon
Characteristics of nanoparticles in drinking water treatment were performed using five types of biological activated carbon (BAC) columns (BAC1-BAC5) in continuous flow experiments. The BAC was created by covering granular activated carbon (GAC) with attached microorganisms from water samples taken from the Nagara River in Japan. The total running time was about 2000 h. The characteristics of the nanoparticles were investigated based on size distribution and volume distribution measured by Zetasizer Nano. Total dissolved organic carbon (DOC) and ultraviolet absorbance at 260 nm (UV260) were also studied. The important results in this study were that the detached nanoparticles in the effluent were within the size distribution ranges of 0.26~5.62 nm, 0.62~3.62 nm, 0.62~3.12 nm, 0.62~4.19 nm, and 0.62~6.50 for BAC 1, 2, 3, 4 and 5, respectively. The profile of peak size and peak number along the bed depth of the BAC columns was evaluated for better understanding the characteristics of the nanoparticles. This result is very important for improving drinking water treatment using granular activated carbon to remove microorganisms.
- Open Access
- 14 March 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 156, 03038
Drinking Water Treatment by Inductively Coupled Plasma System to Remove of Microorganisms in River Water
Inductively coupled plasma system was used in drinking water treatment system to kill the microorganisms in water such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC) from river water. The aim of this study was to investigate the effect of flowrate on removal efficiency (RE), death rate, and death yield and energy consumption of bacteria's. The frequency of the system was set at 4.6 MHz. The results show that the removal efficiencies and death rate of TC, FC and OC decreased with increasing flowrate. Compared to FC, the first-order reactions of TC and OC were lower in the following order: FC > OC > TC. The death yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 19.44 to 20.55 W/cm2 and the energy consumption was 0.26, 0.32, and 0.67 with flow rate at 20, 10 and 5 mL/minute, respectively. These results are very necessary to improve drinking water treatment.
- 14 March 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 156, 03038
Open AccessDrinking Water Treatment by Inductively Coupled Plasma System to Remove of Microorganisms in River Water
Inductively coupled plasma system was used in drinking water treatment system to kill the microorganisms in water such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC) from river water. The aim of this study was to investigate the effect of flowrate on removal efficiency (RE), death rate, and death yield and energy consumption of bacteria's. The frequency of the system was set at 4.6 MHz. The results show that the removal efficiencies and death rate of TC, FC and OC decreased with increasing flowrate. Compared to FC, the first-order reactions of TC and OC were lower in the following order: FC > OC > TC. The death yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 19.44 to 20.55 W/cm2 and the energy consumption was 0.26, 0.32, and 0.67 with flow rate at 20, 10 and 5 mL/minute, respectively. These results are very necessary to improve drinking water treatment.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1931 (1) , 030012
Behavior of microorganisms in drinking water treatment by inductively coupled plasma system: Case study in ground water
Pathogenic bacteria, such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC), were removed from groundwater by inductively coupled plasma system treatment in continuous flow experiments. The objective of this study is to investigate the effect of flowrate and frequency on the behavior of microorganisms in drinking water treatment using inductively coupled plasma system (ICPS). The results showed that after 120 minutes of ICPS treatment, the removal efficiency with respect to TC, FC and OC decreased with increasing flowrate. The removal efficiency of FC was achieved at 100% in all runs. Compared to FC, the removal efficiencies with respect to TC and FC were lower than those with respect to TC and OC in the following order: FC >OC> TC. The disinfection yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 8.08±0.46 to 10.54±0.19 W/cm2. The results in the present work can be used to design a new technology for drinking water treatment to remove all pathogenic bacteria without using hazardous chemicals.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1931 (1) , 030012
Behavior of microorganisms in drinking water treatment by inductively coupled plasma system: Case study in ground water
Pathogenic bacteria, such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC), were removed from groundwater by inductively coupled plasma system treatment in continuous flow experiments. The objective of this study is to investigate the effect of flowrate and frequency on the behavior of microorganisms in drinking water treatment using inductively coupled plasma system (ICPS). The results showed that after 120 minutes of ICPS treatment, the removal efficiency with respect to TC, FC and OC decreased with increasing flowrate. The removal efficiency of FC was achieved at 100% in all runs. Compared to FC, the removal efficiencies with respect to TC and FC were lower than those with respect to TC and OC in the following order: FC >OC> TC. The disinfection yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 8.08±0.46 to 10.54±0.19 W/cm2. The results in the present work can be used to design a new technology for drinking water treatment to remove all pathogenic bacteria without using hazardous chemicals.
- Open Access
- 29 December 2017
- Published by The Institute for Research and Community Services (LPPM) ITB in Journal of Engineering and Technological Sciences
- Vol. 49 (6) , 737-749
Disinfection Performance against Salmonella Typhi in Water by Radio Frequency Inductive Couple Plasma System
Disinfection Performance against Salmonella Typhi in Water by Radio Frequency Inductive Couple Plasma System
- 29 December 2017
- Published by The Institute for Research and Community Services (LPPM) ITB in Journal of Engineering and Technological Sciences
- Vol. 49 (6) , 737-749
Open AccessDisinfection Performance against Salmonella Typhi in Water by Radio Frequency Inductive Couple Plasma System
Disinfection Performance against Salmonella Typhi in Water by Radio Frequency Inductive Couple Plasma System
- Open Access
- 1 July 2017
- Published by Universitas Ahmad Dahlan in CHEMICA: Jurnal Teknik Kimia
- Vol. 4 (1) , 27-32
Kombinasi Proses Filtrasi dan Ion Exchange Secara Kontinu pada Pembuatan Aquadm (Demineralized Water)
Demineralized water is water free of dissolved mineral. Combination of filtration and ion exchanger processes were studied to treat demineralized water. The source of raw water is from Mountain Talang in District Solok. The study was conducted to investigate the effect of the amount of resin cartridge to electric conductivity (EC), pH and total dissolved solid (TDS). The flow rate was set at 50 ml/menit. The results showed that the number of resin cartridge 4 (2 anion and cation 2), the removal efficiency of EC and TDS achieved at 89.09% and 90.91%, respectively. As for the number of cartridges 6 (3 anions and cations 3), the removal efficiency of EC and TDS obtained at 95.45% and 96.36%, respectively. In addition, the effect of flow rate was also studied using cartridges resin 6 (3 anions and cations 3). Demineralized water has met the quality standard with a value of 0 ppm TDS, EC 0 μS / cm, pH 7.5. This studies shown that the combination of filtration and ion exchange filtration process can use effectively to treat demineralized water with high quality standard.
- 1 July 2017
- Published by Universitas Ahmad Dahlan in CHEMICA: Jurnal Teknik Kimia
- Vol. 4 (1) , 27-32
Open AccessKombinasi Proses Filtrasi dan Ion Exchange Secara Kontinu pada Pembuatan Aquadm (Demineralized Water)
Demineralized water is water free of dissolved mineral. Combination of filtration and ion exchanger processes were studied to treat demineralized water. The source of raw water is from Mountain Talang in District Solok. The study was conducted to investigate the effect of the amount of resin cartridge to electric conductivity (EC), pH and total dissolved solid (TDS). The flow rate was set at 50 ml/menit. The results showed that the number of resin cartridge 4 (2 anion and cation 2), the removal efficiency of EC and TDS achieved at 89.09% and 90.91%, respectively. As for the number of cartridges 6 (3 anions and cations 3), the removal efficiency of EC and TDS obtained at 95.45% and 96.36%, respectively. In addition, the effect of flow rate was also studied using cartridges resin 6 (3 anions and cations 3). Demineralized water has met the quality standard with a value of 0 ppm TDS, EC 0 μS / cm, pH 7.5. This studies shown that the combination of filtration and ion exchange filtration process can use effectively to treat demineralized water with high quality standard.
- Open Access
- 1 September 2014
- Published by Universitas Andalas in JURNAL NASIONAL TEKNIK ELEKTRO
- Vol. 3 (2) , 142-147
Teknologi Sistem Plasma Radio –Frekuensi (RF) Untuk Menghilangkan Bakteri Escherichia Coli Pada Air Minum
Jurnal Nasional Teknik Elektro
- 1 September 2014
- Published by Universitas Andalas in JURNAL NASIONAL TEKNIK ELEKTRO
- Vol. 3 (2) , 142-147
Open AccessTeknologi Sistem Plasma Radio –Frekuensi (RF) Untuk Menghilangkan Bakteri Escherichia Coli Pada Air Minum
Jurnal Nasional Teknik Elektro
- Open Access
- 1 September 2014
- Published by Universitas Andalas in JURNAL NASIONAL TEKNIK ELEKTRO
- Vol. 3 (2) , 142-147
Teknologi Sistem Plasma Radio –Frekuensi (RF) Untuk Menghilangkan Bakteri Escherichia Coli Pada Air Minum
Refill drinking water is a source of public drinking water in Indonesia, but the quality is not guaranteed. less optimal means of water treatment to remove pollutants in Drinking Water Refill (AMIU), especially for raw water containing total coliforms and fecal coliforms cause AMIU quality is uncontrolled. The use of radio frequency plasma technology on AMIU processing system can be used as a solution. Induced plasma system by radio frequency in water can form the active compound. The active compounds will react to microorganisms and causing microorganisms be reduced. In testing wastewater 35,000 MPN (100 %), with plasma frequency of 3,3 MHz, the bacteria can degrade to 6 % and with frequency of 3,7 MHz bacteria can degrade to 0,07 %. 23.000 MPN testing river water (100 %), with plasma frequency of 3,3 MHz setting can degrade the bacteria to 9 % and with 3,7 MHz frequency setting can degrade the bacteria to 6 %. Keyword : plasma, radio frequency, total coliform, fecal coliform Abstrak Air minum isi ulang merupakan salah satu sumber air minum masyarakat di Indonesia, namun kualitasnya tidak terjamin. Kurang optimalnya alat pengolah air guna menghilangkan polutan produk pada Air Minum Isi Ulang (AMIU), terutama untuk air baku yang mengandung total coliforms maupun fecal coliforms menyebabkan kualitas AMIU tidak terkontrol dengan baik. Penggunaan teknologi plasma radio frekuensi pada sistem pengolahan AMIU bisa dijadikan solusi. Sistem plasma yang terinduksi melalui radio frekuensi pada air dapat membentuk senyawa aktif. Senyawa aktif ini akan bereaksi terhadap mikroorganisme dan menyebabkan mikroorganisme mati. Pada pengujian air limbah 350.000 MPN (100 %), dengan frekuensi plasma 3,3 MHz dapat mendegradasi bakteri sampai 6 % dan dengan settingan frekuensi 3,7 MHz dapat mendegradasi bakteri hingga 0,07 %. Pada pengujian air sungai 23.000 MPN (100 %), dengan settingan frekuensi plasma 3,3 MHz dapat mendegradasi bakteri hingga 9 % dan dengan settingan frekuensi 3,7 MHz dapat mendegradasi bakteri hinggaa 6 %. Kata kunci : plasma, radio frekuensi, total coliform, fecal coliform.
- 1 September 2014
- Published by Universitas Andalas in JURNAL NASIONAL TEKNIK ELEKTRO
- Vol. 3 (2) , 142-147
Open AccessTeknologi Sistem Plasma Radio –Frekuensi (RF) Untuk Menghilangkan Bakteri Escherichia Coli Pada Air Minum
Refill drinking water is a source of public drinking water in Indonesia, but the quality is not guaranteed. less optimal means of water treatment to remove pollutants in Drinking Water Refill (AMIU), especially for raw water containing total coliforms and fecal coliforms cause AMIU quality is uncontrolled. The use of radio frequency plasma technology on AMIU processing system can be used as a solution. Induced plasma system by radio frequency in water can form the active compound. The active compounds will react to microorganisms and causing microorganisms be reduced. In testing wastewater 35,000 MPN (100 %), with plasma frequency of 3,3 MHz, the bacteria can degrade to 6 % and with frequency of 3,7 MHz bacteria can degrade to 0,07 %. 23.000 MPN testing river water (100 %), with plasma frequency of 3,3 MHz setting can degrade the bacteria to 9 % and with 3,7 MHz frequency setting can degrade the bacteria to 6 %. Keyword : plasma, radio frequency, total coliform, fecal coliform Abstrak Air minum isi ulang merupakan salah satu sumber air minum masyarakat di Indonesia, namun kualitasnya tidak terjamin. Kurang optimalnya alat pengolah air guna menghilangkan polutan produk pada Air Minum Isi Ulang (AMIU), terutama untuk air baku yang mengandung total coliforms maupun fecal coliforms menyebabkan kualitas AMIU tidak terkontrol dengan baik. Penggunaan teknologi plasma radio frekuensi pada sistem pengolahan AMIU bisa dijadikan solusi. Sistem plasma yang terinduksi melalui radio frekuensi pada air dapat membentuk senyawa aktif. Senyawa aktif ini akan bereaksi terhadap mikroorganisme dan menyebabkan mikroorganisme mati. Pada pengujian air limbah 350.000 MPN (100 %), dengan frekuensi plasma 3,3 MHz dapat mendegradasi bakteri sampai 6 % dan dengan settingan frekuensi 3,7 MHz dapat mendegradasi bakteri hingga 0,07 %. Pada pengujian air sungai 23.000 MPN (100 %), dengan settingan frekuensi plasma 3,3 MHz dapat mendegradasi bakteri hingga 9 % dan dengan settingan frekuensi 3,7 MHz dapat mendegradasi bakteri hinggaa 6 %. Kata kunci : plasma, radio frekuensi, total coliform, fecal coliform.
- Open Access
- 1 September 2013
- Published by Universitas Andalas in JURNAL NASIONAL TEKNIK ELEKTRO
- Vol. 2 (2) , 46-50
Aplikasi Plasma Dengan Metoda Dielectric Barrier Discharge (DBD) Untuk Pengolahan Limbah Cair Kelapa Sawit
- 1 September 2013
- Published by Universitas Andalas in JURNAL NASIONAL TEKNIK ELEKTRO
- Vol. 2 (2) , 46-50
Open AccessAplikasi Plasma Dengan Metoda Dielectric Barrier Discharge (DBD) Untuk Pengolahan Limbah Cair Kelapa Sawit