Frederick L. Cardinali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Frederick L. Cardinali has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Benjamin C. Blount
Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention , Atlanta, GA 30341
2 shared publicationsDavid L. Ashley
Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention , Atlanta, GA 30341
1 shared publicationDeborah M. Moll
Division of Environmental Hazards and Health Effects, National Center for Environmental Health, Centers for Disease Control and Prevention , Atlanta, GA 30333
1 shared publicationJohn C. Morrow
Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention , Atlanta, GA 30341
1 shared publicationJohn Morrow
Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention , Atlanta, GA 30341
1 shared publicationRachael Schmidt
Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention , Atlanta, GA 30341
1 shared publication
Latest Publications
- Open Access
- 1 May 2008
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 46 (5) , 381-387
Measurement of Fuel Oxygenates in Tap Water Using Solid-Phase Microextraction Gas Chromatography--Mass Spectrometry
The presence of alkyl ether fuel oxygenates in drinking water supplies has raised public health concerns because of possible adverse health effects from chronic exposure to these compounds. To enable large exposure studies exploring possible relationships between chronic exposure to alkyl ether fuel oxygenates and health effects, we developed an improved analytical method, using headspace solid-phase microextraction coupled with capillary gas chromatography and mass spectrometry. This method quantifies trace levels of methyl tertiary-butyl ether, ethyl tertiary-butyl ether, di-isopropyl ether, and tertiary-amyl methyl ether in tap water. The method achieves detection limits of less than 0.025 µg/L for all analytes and linear ranges of three orders of magnitude in the measurement of the alkyl ether fuel oxygenates in 5-mL tap water samples. The relative percentage of recoveries of the alkyl ether fuel oxygenates ranged from 97% to 105%. The relative standard deviation ranged from 2% to 6%. Methyl tertiary-butyl ether was detected in samples of tap water taken from geographically diverse regions of the United States. The improved throughput and sensitivity of this method will enable large epidemiologic field studies of the prevalence and magnitude of exposure to alkyl ether fuel oxygenates in the general population.
- 1 May 2008
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 46 (5) , 381-387
Open AccessMeasurement of Fuel Oxygenates in Tap Water Using Solid-Phase Microextraction Gas Chromatography--Mass Spectrometry
The presence of alkyl ether fuel oxygenates in drinking water supplies has raised public health concerns because of possible adverse health effects from chronic exposure to these compounds. To enable large exposure studies exploring possible relationships between chronic exposure to alkyl ether fuel oxygenates and health effects, we developed an improved analytical method, using headspace solid-phase microextraction coupled with capillary gas chromatography and mass spectrometry. This method quantifies trace levels of methyl tertiary-butyl ether, ethyl tertiary-butyl ether, di-isopropyl ether, and tertiary-amyl methyl ether in tap water. The method achieves detection limits of less than 0.025 µg/L for all analytes and linear ranges of three orders of magnitude in the measurement of the alkyl ether fuel oxygenates in 5-mL tap water samples. The relative percentage of recoveries of the alkyl ether fuel oxygenates ranged from 97% to 105%. The relative standard deviation ranged from 2% to 6%. Methyl tertiary-butyl ether was detected in samples of tap water taken from geographically diverse regions of the United States. The improved throughput and sensitivity of this method will enable large epidemiologic field studies of the prevalence and magnitude of exposure to alkyl ether fuel oxygenates in the general population.
- Open Access
- 1 April 2004
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 42 (4) , 200-206
Measurement of Trihalomethanes and Methyl Tertiary-Butyl Ether in Tap Water Using Solid-Phase Microextraction GC-MS
The prevalence of water disinfection byproducts in drinking water supplies has raised concerns about possible health effects from chronic exposure to these compounds. To support studies exploring the relation between exposure to trihalomethanes (THMs) and health effects, we have developed an automated analytical method using headspace solid-phase microextraction coupled with capillary gas chromatography and mass spectrometry. This method quantitates trace levels of THMs (chloroform, bromodichloromethane, dibromochloromethane, and bromoform) and methyl tertiary-butyl ether in tap water. Detection limits of less than 100 ng/L for all analytes and linear ranges of three orders of magnitude are adequate for measuring the THMs in tap water samples tested from across the United States. THMs are stable for extended periods in tap water samples after quenching of residual chlorine and buffering to pH 6.5, thus enabling larger epidemiologic field studies with simplified sample collection protocols.
- 1 April 2004
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 42 (4) , 200-206
Open AccessMeasurement of Trihalomethanes and Methyl Tertiary-Butyl Ether in Tap Water Using Solid-Phase Microextraction GC-MS
The prevalence of water disinfection byproducts in drinking water supplies has raised concerns about possible health effects from chronic exposure to these compounds. To support studies exploring the relation between exposure to trihalomethanes (THMs) and health effects, we have developed an automated analytical method using headspace solid-phase microextraction coupled with capillary gas chromatography and mass spectrometry. This method quantitates trace levels of THMs (chloroform, bromodichloromethane, dibromochloromethane, and bromoform) and methyl tertiary-butyl ether in tap water. Detection limits of less than 100 ng/L for all analytes and linear ranges of three orders of magnitude are adequate for measuring the THMs in tap water samples tested from across the United States. THMs are stable for extended periods in tap water samples after quenching of residual chlorine and buffering to pH 6.5, thus enabling larger epidemiologic field studies with simplified sample collection protocols.