Pratik Sinha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pratik Sinha has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Neil Soni
Chelsea and Westminster Hospital
2 shared publicationsN. Soni
1 shared publicationN.J. Fauvel
1 shared publication- Neil Soni
Co-editor JICS, Consultant Intensivist, Chelsea and Westminister Hospital
1 shared publication - Nicholas J Fauvel
Magill Department of Anaesthesia, Intensive Care Medicine and Pain Management, Chelsea and Westminster Hospital, 369 Fulham Road, London SW10 9NH, UK
1 shared publication Oliver Flower
University College London Hospitals’ NHS Foundation Trust
1 shared publication
Latest Publications
- Open Access
- 27 February 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (1) , R34
Analysis of ventilatory ratio as a novel method to monitor ventilatory adequacy at the bedside
Introduction: Due to complexities in its measurement, adequacy of ventilation is seldom used to categorize disease severity and guide ventilatory strategies. Ventilatory ratio (VR) is a novel index to monitor ventilatory adequacy at the bedside. VR = ( V ˙ E m e a s u r e d × P a C O 2 m e a s u r e d ) / ( V ˙ E p r e d i c t e d × P a C O 2 i d e a l ) . V ˙ E p r e d i c t e d is 100 mL.Kg-1.min-1 and P a C O 2 i d e a l is 5 kPa. Physiological analysis shows that VR is influenced by dead space (VD/VT) and CO2 production ( V ˙ C O 2 ) . Two studies were conducted to explore the physiological properties of VR and assess its use in clinical practice. Methods: Both studies were conducted in adult mechanically ventilated ICU patients. In Study 1, volumetric capnography was used to estimate daily VD/VT and measure V ˙ C O 2 in 48 patients. Simultaneously, ventilatory ratio was calculated using arterial blood gas measurements alongside respiratory and ventilatory variables. This data was used to explore the physiological properties of VR. In Study 2, 224 ventilated patients had daily VR and other respiratory variables, baseline characteristics, and outcome recorded. The database was used to examine the prognostic value of VR. Results: Study 1 showed that there was significant positive correlation between VR and VD/VT (modified r = 0.71) and V ˙ C O 2 (r = 0.14). The correlation between VR and VD/VT was stronger in mandatory ventilation compared to spontaneous ventilation. Linear regression analysis showed that VD/VT had a greater influence on VR than V ˙ C O 2 (standardized regression coefficient 1/1-VD/VT: 0.78, V ˙ C O 2 : 0.44). Study 2 showed that VR was significantly higher in non-survivors compared to survivors (1.55 vs. 1.32; P < 0.01). Univariate logistic regression showed that higher VR was associated with mortality (OR 2.3, P < 0.01), this remained the case after adjusting for confounding variables (OR 2.34, P = 0.04). Conclusions: VR is an easy to calculate bedside index of ventilatory adequacy and appears to yield clinically useful information.
- 27 February 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (1) , R34
Open AccessAnalysis of ventilatory ratio as a novel method to monitor ventilatory adequacy at the bedside
Introduction: Due to complexities in its measurement, adequacy of ventilation is seldom used to categorize disease severity and guide ventilatory strategies. Ventilatory ratio (VR) is a novel index to monitor ventilatory adequacy at the bedside. VR = ( V ˙ E m e a s u r e d × P a C O 2 m e a s u r e d ) / ( V ˙ E p r e d i c t e d × P a C O 2 i d e a l ) . V ˙ E p r e d i c t e d is 100 mL.Kg-1.min-1 and P a C O 2 i d e a l is 5 kPa. Physiological analysis shows that VR is influenced by dead space (VD/VT) and CO2 production ( V ˙ C O 2 ) . Two studies were conducted to explore the physiological properties of VR and assess its use in clinical practice. Methods: Both studies were conducted in adult mechanically ventilated ICU patients. In Study 1, volumetric capnography was used to estimate daily VD/VT and measure V ˙ C O 2 in 48 patients. Simultaneously, ventilatory ratio was calculated using arterial blood gas measurements alongside respiratory and ventilatory variables. This data was used to explore the physiological properties of VR. In Study 2, 224 ventilated patients had daily VR and other respiratory variables, baseline characteristics, and outcome recorded. The database was used to examine the prognostic value of VR. Results: Study 1 showed that there was significant positive correlation between VR and VD/VT (modified r = 0.71) and V ˙ C O 2 (r = 0.14). The correlation between VR and VD/VT was stronger in mandatory ventilation compared to spontaneous ventilation. Linear regression analysis showed that VD/VT had a greater influence on VR than V ˙ C O 2 (standardized regression coefficient 1/1-VD/VT: 0.78, V ˙ C O 2 : 0.44). Study 2 showed that VR was significantly higher in non-survivors compared to survivors (1.55 vs. 1.32; P < 0.01). Univariate logistic regression showed that higher VR was associated with mortality (OR 2.3, P < 0.01), this remained the case after adjusting for confounding variables (OR 2.34, P = 0.04). Conclusions: VR is an easy to calculate bedside index of ventilatory adequacy and appears to yield clinically useful information.
- 15 August 2012
- Published by Springer Nature in Intensive Care Medicine
- Vol. 38 (10) , 1712-1717
Comparison of volumetric capnography and mixed expired gas methods to calculate physiological dead space in mechanically ventilated ICU patients
Physiological dead space should be a routine measurement in ventilated patients but measuring dead space using the Douglas bag (DB) method is cumbersome and requires corrections for compressed ventilator gas. These factors make this method impractical in the critical care setting. Volumetric capnography (VCAP) offers a relatively simple solution to calculating dead space. Few studies have been conducted to directly compare dead space measured by VCAP and the DB method in critically unwell adults. Prospective observational study of 48 mechanically ventilated adults ICU patients. Dead space was calculated simultaneously using VCAP (CO2SMO) and the Bohr–Enghoff equation. In total, 168 paired readings were taken. Single-breath CO2 waveform areas under the curve were computed automatically by software to calculate physiological dead space. The calculated value of \( P_{{\bar{E}_{{{\text{CO}}_{2} }} }} \) was also recorded from the CO2SMO device. Exhaust ventilator gas was collected in a 10-l mixing chamber. \( P_{{\bar{E}_{{{\text{CO}}_{2} }} }} \) was measured in the chamber following correction for compressed gas. The study demonstrated good agreement between physiological V D/V T calculated by VCAP and corrected (mean bias 0.03), and uncorrected (mean bias 0.02) Bohr–Enghoff method. There was good correlation between the two methods of measurement (VCAP vs corrected r 2 = 0.90 P < 0.001, VCAP vs uncorrected r 2 = 0.90, P < 0.001). There was good correlation between \( P_{{\bar{E}_{{{\text{CO}}_{2} }} }} \) calculated by the CO2SMO and in the exhaust collected gas (mean bias 0.08). VCAP shows good agreement with Douglas Bag method in measuring physiological V D/V T over a wide range of dead space fractions.- 15 August 2012
- Published by Springer Nature in Intensive Care Medicine
- Vol. 38 (10) , 1712-1717
Comparison of volumetric capnography and mixed expired gas methods to calculate physiological dead space in mechanically ventilated ICU patients
Physiological dead space should be a routine measurement in ventilated patients but measuring dead space using the Douglas bag (DB) method is cumbersome and requires corrections for compressed ventilator gas. These factors make this method impractical in the critical care setting. Volumetric capnography (VCAP) offers a relatively simple solution to calculating dead space. Few studies have been conducted to directly compare dead space measured by VCAP and the DB method in critically unwell adults. Prospective observational study of 48 mechanically ventilated adults ICU patients. Dead space was calculated simultaneously using VCAP (CO2SMO) and the Bohr–Enghoff equation. In total, 168 paired readings were taken. Single-breath CO2 waveform areas under the curve were computed automatically by software to calculate physiological dead space. The calculated value of \( P_{{\bar{E}_{{{\text{CO}}_{2} }} }} \) was also recorded from the CO2SMO device. Exhaust ventilator gas was collected in a 10-l mixing chamber. \( P_{{\bar{E}_{{{\text{CO}}_{2} }} }} \) was measured in the chamber following correction for compressed gas. The study demonstrated good agreement between physiological V D/V T calculated by VCAP and corrected (mean bias 0.03), and uncorrected (mean bias 0.02) Bohr–Enghoff method. There was good correlation between the two methods of measurement (VCAP vs corrected r 2 = 0.90 P < 0.001, VCAP vs uncorrected r 2 = 0.90, P < 0.001). There was good correlation between \( P_{{\bar{E}_{{{\text{CO}}_{2} }} }} \) calculated by the CO2SMO and in the exhaust collected gas (mean bias 0.08). VCAP shows good agreement with Douglas Bag method in measuring physiological V D/V T over a wide range of dead space fractions.- 11 March 2011
- Published by Springer Nature in Intensive Care Medicine
- Vol. 37 (5) , 735-746
Deadspace ventilation: a waste of breath!
Problems with ventilatory efficiency results in abnormal CO2 clearance. Measuring deadspace ventilation should be the most reliable method of monitoring ventilatory efficiency in mechanically ventilated patients. Since its first description by Bohr in the late 19th century to the current use of single-breath test for volumetric CO2, our understanding of the physiological deadspace has vastly improved. Yet indices of oxygenation seem to be the mainstay when instigating or fine-tuning ventilatory strategies. Deadspace and with it ventilatory efficiency has been largely forgotten. Recently though there has been a resurgence of interest in ventilatory efficiency. Several indices have been described that either predict deadspace or track ventilatory efficiency at the bedside. Thus making it more accessible and easy to monitor and study in large groups of patients, factors which have perhaps resulted in its under-utilisation in critical care. This review revisits the physiological concepts and methods of measuring deadspace. Described are the various clinical applications of deadspace measurements in the critically unwell. The potential reasons that have led to the variable being under-used are also examined. Finally we describe the indices currently available to track ventilatory efficiency at the bedside.
- 11 March 2011
- Published by Springer Nature in Intensive Care Medicine
- Vol. 37 (5) , 735-746
Deadspace ventilation: a waste of breath!
Problems with ventilatory efficiency results in abnormal CO2 clearance. Measuring deadspace ventilation should be the most reliable method of monitoring ventilatory efficiency in mechanically ventilated patients. Since its first description by Bohr in the late 19th century to the current use of single-breath test for volumetric CO2, our understanding of the physiological deadspace has vastly improved. Yet indices of oxygenation seem to be the mainstay when instigating or fine-tuning ventilatory strategies. Deadspace and with it ventilatory efficiency has been largely forgotten. Recently though there has been a resurgence of interest in ventilatory efficiency. Several indices have been described that either predict deadspace or track ventilatory efficiency at the bedside. Thus making it more accessible and easy to monitor and study in large groups of patients, factors which have perhaps resulted in its under-utilisation in critical care. This review revisits the physiological concepts and methods of measuring deadspace. Described are the various clinical applications of deadspace measurements in the critically unwell. The potential reasons that have led to the variable being under-used are also examined. Finally we describe the indices currently available to track ventilatory efficiency at the bedside.
- 1 May 2009
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 102 (5) , 692-697
Ventilatory ratio: a simple bedside measure of ventilation
Measures of oxygenation are traditionally used to monitor the progress of patients on positive pressure ventilation. Although CO2 elimination depends on fewer variables, measures of CO2 elimination are comparatively overlooked except when monitoring patients who are difficult to ventilate. CO2 elimination is dependent upon CO2 production and alveolar ventilation, which together determine Pa(CO2). Alveolar ventilation is the efficient portion of minute ventilation ('E'). In the clinical setting, problems with CO2 elimination are observed as increasing Pa(CO2), increasing minute ventilation, or both. In conventional tests of respiratory function, actual measurements are frequently compared with predicted measurements. However, this approach has rarely been applied to the measurement of ventilatory efficiency. We have developed a ratio, called the ventilatory ratio (VR), which compares actual measurements and predicted values of minute ventilation and Pa(CO2). VR = (V(E measured) x Pa(CO2 measured))/(V(E predicted) x Pa(CO2 predicted)). V(E predicted) is taken to be 100 (ml kg(-1) min(-1)) based on predicted body weight, and Pa(CO2 predicted)) is taken to be 5 kPa. Inspection shows VR to be a unitless ratio that can be easily calculated at the bedside. VR is governed by carbon dioxide production and ventilatory efficiency in a logically intuitive way. We suggest that VR provides a simple guide to changes in ventilatory efficiency. A value close to 1 is predicted for normal individuals and an increasing value would correspond with worsening ventilation, increased CO2 production, or both. VR is a new tool providing additional information for clinicians managing ventilated patients.
- 1 May 2009
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 102 (5) , 692-697
Ventilatory ratio: a simple bedside measure of ventilation
Measures of oxygenation are traditionally used to monitor the progress of patients on positive pressure ventilation. Although CO2 elimination depends on fewer variables, measures of CO2 elimination are comparatively overlooked except when monitoring patients who are difficult to ventilate. CO2 elimination is dependent upon CO2 production and alveolar ventilation, which together determine Pa(CO2). Alveolar ventilation is the efficient portion of minute ventilation ('E'). In the clinical setting, problems with CO2 elimination are observed as increasing Pa(CO2), increasing minute ventilation, or both. In conventional tests of respiratory function, actual measurements are frequently compared with predicted measurements. However, this approach has rarely been applied to the measurement of ventilatory efficiency. We have developed a ratio, called the ventilatory ratio (VR), which compares actual measurements and predicted values of minute ventilation and Pa(CO2). VR = (V(E measured) x Pa(CO2 measured))/(V(E predicted) x Pa(CO2 predicted)). V(E predicted) is taken to be 100 (ml kg(-1) min(-1)) based on predicted body weight, and Pa(CO2 predicted)) is taken to be 5 kPa. Inspection shows VR to be a unitless ratio that can be easily calculated at the bedside. VR is governed by carbon dioxide production and ventilatory efficiency in a logically intuitive way. We suggest that VR provides a simple guide to changes in ventilatory efficiency. A value close to 1 is predicted for normal individuals and an increasing value would correspond with worsening ventilation, increased CO2 production, or both. VR is a new tool providing additional information for clinicians managing ventilated patients.