Tomoya Hayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tomoya Hayashi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
S. Tanaka
Japanese Red Cross Osaka Blood Center
3 shared publicationsY. Hori
Japanese Red Cross Osaka Blood Center
3 shared publicationsFumiya Hirayama
Japanese Red Cross Osaka Blood Center, Osaka, Japan
2 shared publicationsM. Inoue
Department of Biochemistry and Molecular Pathology, Medical School, Osaka City University, Osaka, Japan
2 shared publicationsC. Terada
Department of Research, Osaka Red Cross Blood Center, Osaka, Japan
1 shared publicationE. Amakishi
Japanese Red Cross Osaka Blood Center
1 shared publication
Latest Publications
- 9 August 2012
- Published by Wiley in Transfusion
- Vol. 52 (8) , 1837-1838
High‐resolution melting method for genotyping human platelet antigens on ITGB3 Exon 11
- 9 August 2012
- Published by Wiley in Transfusion
- Vol. 52 (8) , 1837-1838
High‐resolution melting method for genotyping human platelet antigens on ITGB3 Exon 11
- 1 February 2011
- Published by Springer Nature in International Journal of Hematology
- Vol. 93 (2) , 170-175
Establishment of a cell line panel for the detection of antibodies against human platelet antigen 4b
Antibodies against human platelet antigens (HPAs) play important roles in thrombocytopenia. In Japan, HPA-4b antibody is frequently responsible for HPA-related neonatal alloimmune thrombocytopenia. A highly sensitive assay using platelets has been developed for the detection of antibodies against HPAs. However, it is difficult to obtain the platelets expressing specific HPAs required for the assay. Therefore, an alternative method not requiring platelets would be helpful to detect antibodies against HPAs. Glycoprotein IIIa (GPIIIa) cDNA encoding HPA-4b was individually co-transduced with that of wild-type GPIIb in K562 cells, which is a non-adherent cell line, using a retroviral vector. The expression of transgene products in cultured cells were observed for over 6 months. Next, to evaluating the sensitivity and specificity of this cell line panel, we performed monoclonal antibody-specific immobilization of platelet antigens (MAIPA) assay with a serum previously identified by another method. All HPA-4b antibodies in serum samples were positive, and all serum samples, including normal serum and serum containing HLA antibodies were negative. No difference was observed in the specificity and sensitivity between our method and conventional MAIPA using platelets. The present results indicate that this established cell line panel permits highly sensitive detection of specific antibodies against HPA-4b.
- 1 February 2011
- Published by Springer Nature in International Journal of Hematology
- Vol. 93 (2) , 170-175
Establishment of a cell line panel for the detection of antibodies against human platelet antigen 4b
Antibodies against human platelet antigens (HPAs) play important roles in thrombocytopenia. In Japan, HPA-4b antibody is frequently responsible for HPA-related neonatal alloimmune thrombocytopenia. A highly sensitive assay using platelets has been developed for the detection of antibodies against HPAs. However, it is difficult to obtain the platelets expressing specific HPAs required for the assay. Therefore, an alternative method not requiring platelets would be helpful to detect antibodies against HPAs. Glycoprotein IIIa (GPIIIa) cDNA encoding HPA-4b was individually co-transduced with that of wild-type GPIIb in K562 cells, which is a non-adherent cell line, using a retroviral vector. The expression of transgene products in cultured cells were observed for over 6 months. Next, to evaluating the sensitivity and specificity of this cell line panel, we performed monoclonal antibody-specific immobilization of platelet antigens (MAIPA) assay with a serum previously identified by another method. All HPA-4b antibodies in serum samples were positive, and all serum samples, including normal serum and serum containing HLA antibodies were negative. No difference was observed in the specificity and sensitivity between our method and conventional MAIPA using platelets. The present results indicate that this established cell line panel permits highly sensitive detection of specific antibodies against HPA-4b.
- 6 January 2011
- Published by Wiley in Transfusion Medicine
- Vol. 21 (3) , 166-174
Role of mitochondria in the maintenance of platelet function during in vitro storage
Aims/Objectives: Platelets undergo structural and biochemical alterations during in vitro storage and these are collectively called platelet storage lesions (PSL). The mitochondrion is an important cell organelle involved not only in energy production but also in the regulation of cellular functions and viability. This implies that some platelet functions may be regulated by mitochondria; hence, preservation of mitochondrial functions may be important for the maintenance of platelet quality in stored platelet concentrates (PCs). This work describes the effects of various compounds on mitochondrial functions important for the maintenance of platelet quality in in vitro stored PCs. Methods: PCs were stored at 22 °C with gentle agitation in the presence or absence of 2,4‐dinitrophenol, antimycin A, acetyl‐l‐carnitine and ascorbic acid. The effects of these products on platelet quality were assessed by analysing glucose and lactate concentrations, pH of the storage medium, shape of the platelets, mitochondrial membrane potential and depolarisation, surface expression of CD62P and collagen‐induced platelet aggregation. Results: 2,4‐Dinitrophenol and antimycin A increased PSL levels, whereas acetyl‐l‐carnitine reduced the level of changes in pH and mitochondrial depolarisation. Ascorbic acid in the storage medium resulted in improved levels of collagen‐induced platelet aggregation. However, none of the examined reagents suppressed CD62P expression in platelets. Conclusions: These results suggest that preservation of mitochondrial function is fundamental, but not fully sufficient, for the maintenance of platelet in vitro quality during storage. Further research is necessary to develop methods for preserving both mitochondrial and platelet functions in in vitro stored PCs.
- 6 January 2011
- Published by Wiley in Transfusion Medicine
- Vol. 21 (3) , 166-174
Role of mitochondria in the maintenance of platelet function during in vitro storage
Aims/Objectives: Platelets undergo structural and biochemical alterations during in vitro storage and these are collectively called platelet storage lesions (PSL). The mitochondrion is an important cell organelle involved not only in energy production but also in the regulation of cellular functions and viability. This implies that some platelet functions may be regulated by mitochondria; hence, preservation of mitochondrial functions may be important for the maintenance of platelet quality in stored platelet concentrates (PCs). This work describes the effects of various compounds on mitochondrial functions important for the maintenance of platelet quality in in vitro stored PCs. Methods: PCs were stored at 22 °C with gentle agitation in the presence or absence of 2,4‐dinitrophenol, antimycin A, acetyl‐l‐carnitine and ascorbic acid. The effects of these products on platelet quality were assessed by analysing glucose and lactate concentrations, pH of the storage medium, shape of the platelets, mitochondrial membrane potential and depolarisation, surface expression of CD62P and collagen‐induced platelet aggregation. Results: 2,4‐Dinitrophenol and antimycin A increased PSL levels, whereas acetyl‐l‐carnitine reduced the level of changes in pH and mitochondrial depolarisation. Ascorbic acid in the storage medium resulted in improved levels of collagen‐induced platelet aggregation. However, none of the examined reagents suppressed CD62P expression in platelets. Conclusions: These results suggest that preservation of mitochondrial function is fundamental, but not fully sufficient, for the maintenance of platelet in vitro quality during storage. Further research is necessary to develop methods for preserving both mitochondrial and platelet functions in in vitro stored PCs.
- 6 January 2011
- Published by Wiley in Transfusion Medicine
- Vol. 21 (3) , 199-204
Establishment of a cell line panel as an alternative source of platelet antigens for a screening assay of anti‐human platelet antibodies
Background: A panel of platelets expressing various human platelet antigens (HPAs) for a platelet antibody screening assay is difficult to prepare because some antigens are rarely expressed. Therefore, an alternative method without using platelets would be helpful in detecting HPA antibodies. This study describes the establishment of cell lines that stably express specific HPAs and their application for detecting specific antibodies. Methods: Wild‐type β3, HPA‐1b, ‐6b, ‐7b and ‐7 variant cDNA as well as wild‐type αIIb and HPA‐3b cDNA were individually co‐transduced with wild‐type αIIb and β3 cDNA in the K562 cell line. We performed an immunobead monoclonal antibody immobilisation of platelet antigens (MAIPA) assay to evaluate this cell line panel for antibody detection using identified sera containing HPA antibodies, whose specificities had been determined by the mixed passive haemagglutination test. Results and Conclusion: Of the 12 sera containing HPA‐1a (n = 2), HPA‐3a (n = 6), HPA‐6b (n = 3) or HPA‐7 variant (n = 1) antibodies, all antibodies were detected and determined by our new method, except for two HPA‐3a antibodies. One of the two antibodies was also negative for conventional platelet MAIPA, suggesting that the cell line panel might be used as an alternative source of platelet antigens in the MAIPA assay.
- 6 January 2011
- Published by Wiley in Transfusion Medicine
- Vol. 21 (3) , 199-204
Establishment of a cell line panel as an alternative source of platelet antigens for a screening assay of anti‐human platelet antibodies
Background: A panel of platelets expressing various human platelet antigens (HPAs) for a platelet antibody screening assay is difficult to prepare because some antigens are rarely expressed. Therefore, an alternative method without using platelets would be helpful in detecting HPA antibodies. This study describes the establishment of cell lines that stably express specific HPAs and their application for detecting specific antibodies. Methods: Wild‐type β3, HPA‐1b, ‐6b, ‐7b and ‐7 variant cDNA as well as wild‐type αIIb and HPA‐3b cDNA were individually co‐transduced with wild‐type αIIb and β3 cDNA in the K562 cell line. We performed an immunobead monoclonal antibody immobilisation of platelet antigens (MAIPA) assay to evaluate this cell line panel for antibody detection using identified sera containing HPA antibodies, whose specificities had been determined by the mixed passive haemagglutination test. Results and Conclusion: Of the 12 sera containing HPA‐1a (n = 2), HPA‐3a (n = 6), HPA‐6b (n = 3) or HPA‐7 variant (n = 1) antibodies, all antibodies were detected and determined by our new method, except for two HPA‐3a antibodies. One of the two antibodies was also negative for conventional platelet MAIPA, suggesting that the cell line panel might be used as an alternative source of platelet antigens in the MAIPA assay.
- Open Access
- 3 February 2005
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 3 (3) , 489-496
Insertion of a C in the exon 28 of integrin αIIb gene leading to a frameshift mutation is responsible for Glanzmann thrombasthenia in a Japanese case
- 3 February 2005
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 3 (3) , 489-496
Open AccessInsertion of a C in the exon 28 of integrin αIIb gene leading to a frameshift mutation is responsible for Glanzmann thrombasthenia in a Japanese case