Panu Takala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Panu Takala has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
H Hänninen
BioMag Laboratory, Medical Engineering Centre, Helsinki University Central Hospital, FIN-00029 HUCH, Finland
1 shared publicationH. Hänninen
BioMag Laboratory, Helsinki University Central Hospital, 00029 HUCH, Helsinki, Finland
1 shared publicationHelena Hänninen
Helsinki University Central Hospital
1 shared publicationJ Montonen
Laboratory of Biomedical Engineering, Helsinki University of Technology, FIN-02015 HUT, Finland
1 shared publicationJ Nenonen
Laboratory of Biomedical Engineering, Helsinki University of Technology, FIN-02015 HUT, Finland
1 shared publicationJ. Montonen
Helsinki University of Technology, Laboratory of Biomedical Engineering, P.O. Box 2200, 02015 HUT, Espoo, Finland, Tel.: +358-9/451-5841, Fax: +358-9/451-3182
1 shared publication
Latest Publications
- 1 January 2002
- Published by Springer Nature in Basic Research in Cardiology
- Vol. 97 (1) , 88-96
Heart rate adjustment of magnetic field map rotation in detection of myocardial ischemia in exercise magnetocardiography.
- 1 January 2002
- Published by Springer Nature in Basic Research in Cardiology
- Vol. 97 (1) , 88-96
Heart rate adjustment of magnetic field map rotation in detection of myocardial ischemia in exercise magnetocardiography.
- 1 June 2001
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 29 (6) , 501-509
Magnetocardiographic and Electrocardiographic Exercise Mapping in Healthy Subjects
In 12-lead electrocardiography (ECG), detection of myocardial ischemia is based on ST-segment changes in exercise testing. Magnetocardiography (MCG) is a complementary method to the ECG for a noninvasive study of the electric activity of the heart. In the MCG, ST-segment changes due to stress have also been found in healthy subjects. To further study the normal response to exercise, we performed MCG mappings in 12 healthy volunteers during supine bicycle ergometry. We also recorded body surface potential mappings (BSPM) with 123 channels using the same protocol. In this paper we compare, for the first time, multichannel MCG recorded in bicycle exercise testing with BSPM over the whole thorax in middle-aged healthy subjects. We quantified changes induced by the exercise in the MCG and BSPM with parameters based on signal amplitude, and correlation between signal distributions at rest and after exercise. At the ST-segment and T-wave apex, the exercise induced a magnetic field component outward the precordium and the minimum value of the MCG signal over the mapped area was found to be amplified. The response to exercise was smaller in the BSPM than in the MCG. A negative component in the MCG signal at the repolarization period of the cardiac cycle should be considered as a normal response to exercise. Therefore, maximum ST-segment depression over the mapped area in the MCG may not be an eligible parameter when evaluating the presence of ischemia. © 2001 Biomedical Engineering Society. PAC01: 8719Nn, 8719Hh, 8780Tq
- 1 June 2001
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 29 (6) , 501-509
Magnetocardiographic and Electrocardiographic Exercise Mapping in Healthy Subjects
In 12-lead electrocardiography (ECG), detection of myocardial ischemia is based on ST-segment changes in exercise testing. Magnetocardiography (MCG) is a complementary method to the ECG for a noninvasive study of the electric activity of the heart. In the MCG, ST-segment changes due to stress have also been found in healthy subjects. To further study the normal response to exercise, we performed MCG mappings in 12 healthy volunteers during supine bicycle ergometry. We also recorded body surface potential mappings (BSPM) with 123 channels using the same protocol. In this paper we compare, for the first time, multichannel MCG recorded in bicycle exercise testing with BSPM over the whole thorax in middle-aged healthy subjects. We quantified changes induced by the exercise in the MCG and BSPM with parameters based on signal amplitude, and correlation between signal distributions at rest and after exercise. At the ST-segment and T-wave apex, the exercise induced a magnetic field component outward the precordium and the minimum value of the MCG signal over the mapped area was found to be amplified. The response to exercise was smaller in the BSPM than in the MCG. A negative component in the MCG signal at the repolarization period of the cardiac cycle should be considered as a normal response to exercise. Therefore, maximum ST-segment depression over the mapped area in the MCG may not be an eligible parameter when evaluating the presence of ischemia. © 2001 Biomedical Engineering Society. PAC01: 8719Nn, 8719Hh, 8780Tq
- 1 March 2001
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (4) , 975-982
Beat-to-beat analysis method for magnetocardiographic recordings during interventions
Multichannel magnetocardiography (MCG) during exercise testing has been shown to detect myocardial ischaemia in patients with coronary artery disease. Previous studies on exercise MCG have focused on one or few time intervals during the recovery period and only a fragment of the data available has been utilized. We present a method for beat-to-beat analysis and parametrization of the MCG signal. The method can be used for studying and quantifying the changes induced in the MCG by interventions. We test the method with data recorded in bicycle exercise testing in healthy volunteers and patients with coronary artery disease. Information in all cardiac cycles recorded during the recovery period of exercise MCG testing is, for the first time, utilized in the signal analysis. Exercise-induced myocardial ischaemia was detected by heart rate adjustment of change in magnetic field map orientation. In addition to the ST segment, the T wave in the MCG was also found to provide information related to myocardial ischaemia. The method of analysis efficiently utilizes the spatial and temporal properties of multichannel MCG mapping, providing a new tool for detecting and quantifying fast phenomena during interventional MCG studies. The method can also be applied to an on-line analysis of MCG data.
- 1 March 2001
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (4) , 975-982
Beat-to-beat analysis method for magnetocardiographic recordings during interventions
Multichannel magnetocardiography (MCG) during exercise testing has been shown to detect myocardial ischaemia in patients with coronary artery disease. Previous studies on exercise MCG have focused on one or few time intervals during the recovery period and only a fragment of the data available has been utilized. We present a method for beat-to-beat analysis and parametrization of the MCG signal. The method can be used for studying and quantifying the changes induced in the MCG by interventions. We test the method with data recorded in bicycle exercise testing in healthy volunteers and patients with coronary artery disease. Information in all cardiac cycles recorded during the recovery period of exercise MCG testing is, for the first time, utilized in the signal analysis. Exercise-induced myocardial ischaemia was detected by heart rate adjustment of change in magnetic field map orientation. In addition to the ST segment, the T wave in the MCG was also found to provide information related to myocardial ischaemia. The method of analysis efficiently utilizes the spatial and temporal properties of multichannel MCG mapping, providing a new tool for detecting and quantifying fast phenomena during interventional MCG studies. The method can also be applied to an on-line analysis of MCG data.