J.P. Charton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
J.P. Charton has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
H. Neuhaus
4 shared publicationsB. Schumacher
Evangelisches Krankenhaus
2 shared publicationsA. Nemeth
1 shared publication- André Van Gossum
Erasme Hospital, Free University of Brussels
1 shared publication C. Carretero
1 shared publicationC. Hassan
1 shared publication
Latest Publications
- 1 February 2014
- Published by Georg Thieme Verlag KG in Endo-Praxis
- Vol. 30 (01) , 18-22
POEM – Erste klinische Erfahrungen nach Einführung der neuen Methode zur Behandlung der Achalasie
Die Therapiemöglichkeiten bei Achalasie – Ballondilata-tion, Botulinumtoxin-Injektion und Heller'sche Myotomie – werden durch die neue, minimalinvasive Option der peroralen endoskopischen Myotomie (POEM) ergänzt, die nun auf dem Prüfstand steht.
- 1 February 2014
- Published by Georg Thieme Verlag KG in Endo-Praxis
- Vol. 30 (01) , 18-22
POEM – Erste klinische Erfahrungen nach Einführung der neuen Methode zur Behandlung der Achalasie
Die Therapiemöglichkeiten bei Achalasie – Ballondilata-tion, Botulinumtoxin-Injektion und Heller'sche Myotomie – werden durch die neue, minimalinvasive Option der peroralen endoskopischen Myotomie (POEM) ergänzt, die nun auf dem Prüfstand steht.
- 1 September 2013
- Published by Georg Thieme Verlag KG in Endoskopie heute
- Vol. 26 (03) , 192-195
Kapselendoskopie des Kolons - Update 2013
Die neue Generation der Kolonkapsel stellt eine alternative, sichere und nicht invasive Option zur Visualisierung der Kolonmukosa dar. Empfehlungen bezüglich der Indikationsstellung und Durchführung wurden in einer 2012 publizierten ESGE-Leitlinie prägnant zusammengefasst. Insbesondere bei Kontraindikationen oder nach inkompletter Koloskopie ist die Kolonkapselendoskopie eine sinnvolle Alternative und Ergänzung zur konventionellen Koloskopie. Eine Empfehlung zum Monitoring chronisch entzündlicher Darmerkrankungen mittels Kolonkapsel wird aktuell bei nicht ausreichender Datenlage nicht ausgesprochen, obwohl einige Studien über eine Korrelation zwischen Kapsel- und Koloskopiebefunden berichten. Vielversprechend scheint die Möglichkeit, mit der Kapselendoskopie des Kolons in der Bevölkerung höhere Teilnahmeraten am Screening auf kolorektale Karzinome zu erzielen. Weitere Studien werden zeigen müssen, ob sich hieraus unter Umständen ein erweitertes Einsatzspektrum für die Videokapselendoskopie des Dickdarms ergibt. The new generation of colon capsule provides an alternative, safe and non-invasive option for the visualization of the colonic mucosa. Recommendations on indication and execution have been summarized concisely in a guideline published in 2012 by the ESGE. In case of contraindications or incomplete colonoscopy, the colon capsule is a reasonable alternative and complement to conventional colonoscopy. Currently, a recommendation on monitoring inflammatory bowel disease by the colon capsule is not available because of insufficient data, although some studies have reported of a correlation between capsule and colonoscopy findings. With the introduction of colon capsule endoscopy a higher participation in screening for colorectal cancer may be achieved. Further studies are needed to show if there are extended fields of application for colon capsule endoscopy.
- 1 September 2013
- Published by Georg Thieme Verlag KG in Endoskopie heute
- Vol. 26 (03) , 192-195
Kapselendoskopie des Kolons - Update 2013
Die neue Generation der Kolonkapsel stellt eine alternative, sichere und nicht invasive Option zur Visualisierung der Kolonmukosa dar. Empfehlungen bezüglich der Indikationsstellung und Durchführung wurden in einer 2012 publizierten ESGE-Leitlinie prägnant zusammengefasst. Insbesondere bei Kontraindikationen oder nach inkompletter Koloskopie ist die Kolonkapselendoskopie eine sinnvolle Alternative und Ergänzung zur konventionellen Koloskopie. Eine Empfehlung zum Monitoring chronisch entzündlicher Darmerkrankungen mittels Kolonkapsel wird aktuell bei nicht ausreichender Datenlage nicht ausgesprochen, obwohl einige Studien über eine Korrelation zwischen Kapsel- und Koloskopiebefunden berichten. Vielversprechend scheint die Möglichkeit, mit der Kapselendoskopie des Kolons in der Bevölkerung höhere Teilnahmeraten am Screening auf kolorektale Karzinome zu erzielen. Weitere Studien werden zeigen müssen, ob sich hieraus unter Umständen ein erweitertes Einsatzspektrum für die Videokapselendoskopie des Dickdarms ergibt. The new generation of colon capsule provides an alternative, safe and non-invasive option for the visualization of the colonic mucosa. Recommendations on indication and execution have been summarized concisely in a guideline published in 2012 by the ESGE. In case of contraindications or incomplete colonoscopy, the colon capsule is a reasonable alternative and complement to conventional colonoscopy. Currently, a recommendation on monitoring inflammatory bowel disease by the colon capsule is not available because of insufficient data, although some studies have reported of a correlation between capsule and colonoscopy findings. With the introduction of colon capsule endoscopy a higher participation in screening for colorectal cancer may be achieved. Further studies are needed to show if there are extended fields of application for colon capsule endoscopy.
- 31 March 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43, S115
PC.1.1: SECOND-GENERATION PILLCAM® COLON CAPSULE COMPARED WITH COLONOSCOPY
- 31 March 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43, S115
PC.1.1: SECOND-GENERATION PILLCAM® COLON CAPSULE COMPARED WITH COLONOSCOPY
- 17 October 2009
- Published by Springer Nature in Der Gastroenterologe
- Vol. 4 (6) , 548-551
Ungewöhnliche Ursache einer mittleren gastrointestinalen Blutung bei einer 72-jährigen Patientin
- 17 October 2009
- Published by Springer Nature in Der Gastroenterologe
- Vol. 4 (6) , 548-551
Ungewöhnliche Ursache einer mittleren gastrointestinalen Blutung bei einer 72-jährigen Patientin
- 14 April 2004
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 36 (05) , 464
Reply to Dr. Lapeyre: Duration of Esophagogastroduodenoscopy Procedures
We very much appreciate the letter from Dr. B. Lapeyre, stating his view that the duration of unsedated esophagogastroduodenoscopy (EGD) procedures has an important impact on patients’ tolerance of them. Our data do not support this hypothesis. As we reported, sedation became necessary in 44 % of all conventional EGD procedures. In 86.4 % of these cases (19 of 22 patients), sedation was administered at the patient’s request shortly after insertion of the endoscope. Only 13.6 % of the patients (three of 22) received sedation for the first time at a later stage of EGD [ 1 ]. The differences between our results and those reported in the study by Birkner et al. [ 2 ] appear to have a different basis. One striking difference is that we excluded 19.4 % of the study population when obligatory sedation for EGD was requested. The corresponding rate was 58.7 % (352 of 600) in the study by Birkner et al., suggesting a stronger selection of patients with a high tolerance for unsedated interventions. The time required for EGD probably does not depend on the examiners’ level of expertise in endoscopy, which was high in both groups. In contrast to Birkner et al., we routinely took at least six biopsies per patient, which prolonged the procedure. A procedure time of 3 min for EGD, frequently reported by Western endoscopists, is sufficient to look for obvious reasons for symptoms - e. g., reflux esophagitis, ulcers, or elevated lesions. From our point of view, considerably more time is needed if we follow the strategies used by endoscopists in the Far East, which additionally include a careful search for type O-II lesions or small tongues of Barrett’s epithelium, chromoendoscopy of suspicious areas, and biopsy studies - e. g., to determine the type of gastritis present. In addition, high-quality digital imaging documentation of the esophagogastric junction, all parts of the stomach, and the proximal duodenum, as suggested by the European Society of Gastrointestinal Endoscopy, takes additional time. If an EGD examination is being conducted, the opportunity should be taken to detect or exclude early neoplastic lesions or their precursors - and an average of 9 min does not seem to be too long to do this.
- 14 April 2004
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 36 (05) , 464
Reply to Dr. Lapeyre: Duration of Esophagogastroduodenoscopy Procedures
We very much appreciate the letter from Dr. B. Lapeyre, stating his view that the duration of unsedated esophagogastroduodenoscopy (EGD) procedures has an important impact on patients’ tolerance of them. Our data do not support this hypothesis. As we reported, sedation became necessary in 44 % of all conventional EGD procedures. In 86.4 % of these cases (19 of 22 patients), sedation was administered at the patient’s request shortly after insertion of the endoscope. Only 13.6 % of the patients (three of 22) received sedation for the first time at a later stage of EGD [ 1 ]. The differences between our results and those reported in the study by Birkner et al. [ 2 ] appear to have a different basis. One striking difference is that we excluded 19.4 % of the study population when obligatory sedation for EGD was requested. The corresponding rate was 58.7 % (352 of 600) in the study by Birkner et al., suggesting a stronger selection of patients with a high tolerance for unsedated interventions. The time required for EGD probably does not depend on the examiners’ level of expertise in endoscopy, which was high in both groups. In contrast to Birkner et al., we routinely took at least six biopsies per patient, which prolonged the procedure. A procedure time of 3 min for EGD, frequently reported by Western endoscopists, is sufficient to look for obvious reasons for symptoms - e. g., reflux esophagitis, ulcers, or elevated lesions. From our point of view, considerably more time is needed if we follow the strategies used by endoscopists in the Far East, which additionally include a careful search for type O-II lesions or small tongues of Barrett’s epithelium, chromoendoscopy of suspicious areas, and biopsy studies - e. g., to determine the type of gastritis present. In addition, high-quality digital imaging documentation of the esophagogastric junction, all parts of the stomach, and the proximal duodenum, as suggested by the European Society of Gastrointestinal Endoscopy, takes additional time. If an EGD examination is being conducted, the opportunity should be taken to detect or exclude early neoplastic lesions or their precursors - and an average of 9 min does not seem to be too long to do this.