Kenji Nemoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenji Nemoto has a total of 151 co-authors. Here are the top co-authors by number of shared publications:
- Hiroshi Tsuji
QST Hospital, National Institutes for Quantum Science and Technology, Chiba-Shi 263-8555, Japan
5 shared publications - Takashi Ono
Department of Radiation Oncology, Faculty of Medicine, Yamagata University, Yamagata 990-9585, Japan.
5 shared publications - Hitoshi Wada
Department of Radiation Oncology, Southern TOHOKU Proton Therapy Center, Koriyama, Fukushima 963-8052, Japan
3 shared publications - Keiichi Jingu
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan
3 shared publications - Ken Takeda
Department of Radiological Technology, School of Health Sciences, Faculty of medicine, Tohoku University, Sendai, Japan
3 shared publications - Motohisa Suzuki
Department of Radiation Oncology, Southern TOHOKU Proton Therapy Center, Koriyama 963-8052, Japan
3 shared publications
Latest Publications
- Open Access
The Risk Factors for Radiation Pneumonitis after Single-Fraction Carbon-Ion Radiotherapy for Lung Cancer or Metastasis
There are no studies on the risk factors of radiation pneumonitis (RP) after carbon-ion radiotherapy at a dose of 50 Gy (relative biological effectiveness (RBE)) in a single fraction. The objective of this study was to identify factors associated with RP after radiotherapy, including dose–volume parameters. Ninety-eight patients without a history of thoracic radiotherapy who underwent treatment for solitary lung tumors between July 2013 and April 2016 were retrospectively analyzed. Treatment was planned using Xio-N. The median follow-up duration was 53 months, and the median clinical target volume was 32.3 mL. Three patients developed grade 2 RP, and one patient developed grade 3 interstitial pneumonitis. None of the patients developed grade 4 or 5 RP. The dose-volume parameters of the normal lung irradiated at least with 5–30 Gy (RBE), and the mean lung dose was significantly lower in patients with grade 0–1 RP than in those with grade 2–3 RP. Pretreatment with higher SP-D and interstitial pneumonitis were significant factors for the occurrence of symptomatic RP. The present study showed a certain standard for single-fraction carbon-ion radiotherapy that does not increase the risk of RP; however, further validation studies are needed.
Open AccessThe Risk Factors for Radiation Pneumonitis after Single-Fraction Carbon-Ion Radiotherapy for Lung Cancer or Metastasis
There are no studies on the risk factors of radiation pneumonitis (RP) after carbon-ion radiotherapy at a dose of 50 Gy (relative biological effectiveness (RBE)) in a single fraction. The objective of this study was to identify factors associated with RP after radiotherapy, including dose–volume parameters. Ninety-eight patients without a history of thoracic radiotherapy who underwent treatment for solitary lung tumors between July 2013 and April 2016 were retrospectively analyzed. Treatment was planned using Xio-N. The median follow-up duration was 53 months, and the median clinical target volume was 32.3 mL. Three patients developed grade 2 RP, and one patient developed grade 3 interstitial pneumonitis. None of the patients developed grade 4 or 5 RP. The dose-volume parameters of the normal lung irradiated at least with 5–30 Gy (RBE), and the mean lung dose was significantly lower in patients with grade 0–1 RP than in those with grade 2–3 RP. Pretreatment with higher SP-D and interstitial pneumonitis were significant factors for the occurrence of symptomatic RP. The present study showed a certain standard for single-fraction carbon-ion radiotherapy that does not increase the risk of RP; however, further validation studies are needed.
- Open Access
- 23 June 2021
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (4) , 743
Corrigendum to: Prediction of the minimum spacer thickness required for definitive radiotherapy with carbon ions and photons for pelvic tumors: an in silico planning study using virtual spacers
When this paper first published online, the author name Rei Mastueda was incorrect. It should have been Rei Matsueda. This has now been corrected online.
- 23 June 2021
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (4) , 743
Open AccessCorrigendum to: Prediction of the minimum spacer thickness required for definitive radiotherapy with carbon ions and photons for pelvic tumors: an in silico planning study using virtual spacers
When this paper first published online, the author name Rei Mastueda was incorrect. It should have been Rei Matsueda. This has now been corrected online.
- 1 February 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 155, e18-e19
In response to Liu et al
- 1 February 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 155, e18-e19
In response to Liu et al
- Open Access
Long Term Results of Single-Fraction Carbon-Ion Radiotherapy for Non-small Cell Lung Cancer
Background: The purpose of the present study was to evaluate the efficacy and safety of single-fraction carbon-ion radiotherapy (CIRT) in patients with non-small cell lung cancer. Methods: Patients with histologically confirmed non-small cell lung cancer, stage T1-2N0M0, and treated with single-fraction CIRT (50Gy (relative biological effectiveness)) between June 2011 and April 2016 were identified in our database and retrospectively analyzed. Toxicity was evaluated using the Common Terminology Criteria for Adverse Events version 4.0. Results: The study included 57 patients, 22 (38.6%) of whom had inoperable cancer. The median age was 75 years (range: 42–94 years), and the median follow-up time was 61 months (range: 6–97 months). The 3- and 5-year overall survival rates were 91.2% and 81.7%, respectively. All survivors were followed up for more than three years. The 3- and 5-year local control rates were 96.4% and 91.8%, respectively. No case of ≥ grade 2 pneumonitis was recorded. Conclusions: This study suggests that single-fraction CIRT for T1-2N0M0 non-small cell lung cancer patients is feasible and can be considered as one of the treatment choices, especially in medically inoperable patients.
Open AccessLong Term Results of Single-Fraction Carbon-Ion Radiotherapy for Non-small Cell Lung Cancer
Background: The purpose of the present study was to evaluate the efficacy and safety of single-fraction carbon-ion radiotherapy (CIRT) in patients with non-small cell lung cancer. Methods: Patients with histologically confirmed non-small cell lung cancer, stage T1-2N0M0, and treated with single-fraction CIRT (50Gy (relative biological effectiveness)) between June 2011 and April 2016 were identified in our database and retrospectively analyzed. Toxicity was evaluated using the Common Terminology Criteria for Adverse Events version 4.0. Results: The study included 57 patients, 22 (38.6%) of whom had inoperable cancer. The median age was 75 years (range: 42–94 years), and the median follow-up time was 61 months (range: 6–97 months). The 3- and 5-year overall survival rates were 91.2% and 81.7%, respectively. All survivors were followed up for more than three years. The 3- and 5-year local control rates were 96.4% and 91.8%, respectively. No case of ≥ grade 2 pneumonitis was recorded. Conclusions: This study suggests that single-fraction CIRT for T1-2N0M0 non-small cell lung cancer patients is feasible and can be considered as one of the treatment choices, especially in medically inoperable patients.
- Open Access
- 7 December 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (12) , 3958
Relationship between Standard Uptake Values of Positron Emission Tomography/Computed Tomography and Salivary Metabolites in Oral Cancer: A Pilot Study
18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) is usually used for staging or evaluation of treatment response rather than for cancer screening. However, 18F-FDG PET/CT has also been used in Japan for cancer screening in people with no cancer symptoms, and accumulating evidence supports this application of 18F-FDG PET/CT. Previously, we have observed a correlation between the saliva and tumor metabolomic profiles in patients with oral cancer. Hence, if salivary metabolites demonstrate a significant correlation with PET parameters such as the maximum standardized uptake value (SUVmax), they may have the potential to be used as a screening tool before PET/CT to identify patients with high SUVmax. Hence, in this study, we aimed to explore the relationship between salivary metabolites and SUVmax of 18F-FDG PET/CT using previously collected data. 18F-FDG PET/CT was performed for staging 26 patients with oral cancer. The collected data were integrated and analyzed along with quantified salivary hydrophilic metabolites obtained from the same patients with oral cancer and controls (n = 44). In total, 11 metabolites showed significant correlations with SUVmax in the delayed phases. A multiple logistic regression model of the two metabolites showed the ability to discriminate between patients with oral cancer and controls, with an area under the receiver operating characteristic curve of 0.738 (p = 0.001). This study uniquely confirmed a relationship between salivary metabolites and SUVmax of PET/CT in patients with oral cancer; salivary metabolites were significantly correlated with SUVmax. These salivary metabolites can be used as a screening tool before PET/CT to identify patients with high SUVmax, i.e., to detect the presence of oral cancer.
- 7 December 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (12) , 3958
Open AccessRelationship between Standard Uptake Values of Positron Emission Tomography/Computed Tomography and Salivary Metabolites in Oral Cancer: A Pilot Study
18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) is usually used for staging or evaluation of treatment response rather than for cancer screening. However, 18F-FDG PET/CT has also been used in Japan for cancer screening in people with no cancer symptoms, and accumulating evidence supports this application of 18F-FDG PET/CT. Previously, we have observed a correlation between the saliva and tumor metabolomic profiles in patients with oral cancer. Hence, if salivary metabolites demonstrate a significant correlation with PET parameters such as the maximum standardized uptake value (SUVmax), they may have the potential to be used as a screening tool before PET/CT to identify patients with high SUVmax. Hence, in this study, we aimed to explore the relationship between salivary metabolites and SUVmax of 18F-FDG PET/CT using previously collected data. 18F-FDG PET/CT was performed for staging 26 patients with oral cancer. The collected data were integrated and analyzed along with quantified salivary hydrophilic metabolites obtained from the same patients with oral cancer and controls (n = 44). In total, 11 metabolites showed significant correlations with SUVmax in the delayed phases. A multiple logistic regression model of the two metabolites showed the ability to discriminate between patients with oral cancer and controls, with an area under the receiver operating characteristic curve of 0.738 (p = 0.001). This study uniquely confirmed a relationship between salivary metabolites and SUVmax of PET/CT in patients with oral cancer; salivary metabolites were significantly correlated with SUVmax. These salivary metabolites can be used as a screening tool before PET/CT to identify patients with high SUVmax, i.e., to detect the presence of oral cancer.
- Open Access
- 1 March 2020
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 21, 19-24
Influence of dose-averaged linear energy transfer on tumour control after carbon-ion radiation therapy for pancreatic cancer
- 1 March 2020
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 21, 19-24
Open AccessInfluence of dose-averaged linear energy transfer on tumour control after carbon-ion radiation therapy for pancreatic cancer
- Open Access
- 7 January 2020
- Published by Springer Nature in Esophagus
- Vol. 17 (2) , 122-126
Comparison of the effects of radiotherapy doses of 50.4 Gy and 60 Gy on outcomes of chemoradiotherapy for thoracic esophageal cancer: subgroup analysis based on the Comprehensive Registry of Esophageal Cancer in Japan from 2009 to 2011 by the Japan Esophageal Society
Background: In definitive chemoradiotherapy (CRTx) for esophageal cancer, a radiotherapy (RT) dose of 50.4 Gy in 28 fractions has been the standard in many countries, while 60 Gy in 30 fractions has been frequently used in Japan. To clarify the optimal RT dose in CRTx for esophageal cancer, we compared clinical outcomes with the two doses using data from the Comprehensive Registry of Esophageal Cancer in Japan by the Japan Esophageal Society (JES). Methods: Of the patients enrolled in the registry for 2015–2017 surveys (patients treated between 2009 and 2011), 996 patients who received definitive CRTx with 50.4 Gy or 60 Gy for thoracic esophageal cancer were eligible for analysis. Results: The complete response (CR) rates in the 50.4 Gy and 60 Gy groups were 49.1% and 46.4%, respectively (p = 0.5851). The 5-year overall survival (OS) rates in the 50.4 Gy group and 60 Gy group for stages I, II/III and IV were 64.2% and 57.2%, 35.0% and 27.0%, and 18.0% and 15.3%, respectively. Since no significant difference was found between the two groups, the 50.4 Gy group was not inferior to the 60 Gy group with regard to OS. Conclusions: The analysis revealed that the 50.4 Gy group had a non-inferior outcome in comparison with the 60 Gy group for stages I, II/III and IV thoracic esophageal cancer. These results were obtained from a large database for the first time in Japan.
- 7 January 2020
- Published by Springer Nature in Esophagus
- Vol. 17 (2) , 122-126
Open AccessComparison of the effects of radiotherapy doses of 50.4 Gy and 60 Gy on outcomes of chemoradiotherapy for thoracic esophageal cancer: subgroup analysis based on the Comprehensive Registry of Esophageal Cancer in Japan from 2009 to 2011 by the Japan Esophageal Society
Background: In definitive chemoradiotherapy (CRTx) for esophageal cancer, a radiotherapy (RT) dose of 50.4 Gy in 28 fractions has been the standard in many countries, while 60 Gy in 30 fractions has been frequently used in Japan. To clarify the optimal RT dose in CRTx for esophageal cancer, we compared clinical outcomes with the two doses using data from the Comprehensive Registry of Esophageal Cancer in Japan by the Japan Esophageal Society (JES). Methods: Of the patients enrolled in the registry for 2015–2017 surveys (patients treated between 2009 and 2011), 996 patients who received definitive CRTx with 50.4 Gy or 60 Gy for thoracic esophageal cancer were eligible for analysis. Results: The complete response (CR) rates in the 50.4 Gy and 60 Gy groups were 49.1% and 46.4%, respectively (p = 0.5851). The 5-year overall survival (OS) rates in the 50.4 Gy group and 60 Gy group for stages I, II/III and IV were 64.2% and 57.2%, 35.0% and 27.0%, and 18.0% and 15.3%, respectively. Since no significant difference was found between the two groups, the 50.4 Gy group was not inferior to the 60 Gy group with regard to OS. Conclusions: The analysis revealed that the 50.4 Gy group had a non-inferior outcome in comparison with the 60 Gy group for stages I, II/III and IV thoracic esophageal cancer. These results were obtained from a large database for the first time in Japan.
- Open Access
- 21 November 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-10
In silico comparison of the dosimetric impacts of a greater omentum spacer for abdominal and pelvic tumors in carbon-ion, proton and photon radiotherapy
Purpose: The purpose of this study was to compare carbon-ion (C-ion), proton and photon radiotherapy (RT) plans with regard to dose reduction of the gastrointestinal (GI) tract by using a greater omentum spacer (GO spacer).Methods: We retrospectively retrieved data for ten patients who received the GO spacer as surgical spacer placement for abdominal and pelvic tumors. Simulation plans were created on pre-spacer Computed Tomography (CT) and post-spacer CT for C-ion RT, proton RT and photon RT to compare the dose of the GI tract. The plans were normalized so that at least 95% of the planning target volume (PTV) received 70 Gy (relative biological effectiveness equivalent) delivered in 35 fractions. All plans were created with the lowest possible dose to the GI tract under conditions that meet the dose constraints for the PTV and spinal cord (maximum dose < 45 Gy). The part of the GI tract to be evaluated was defined as that most adjacent to the PTV. C-ion RT plans and proton RT plans were calculated by a spot scanning technique, and photon RT plans were calculated employing by fixed-field intensity-modulated radiation therapy.Results: D2 cc and V10–70 of the GI tract were significantly lower on post-spacer plans than on pre-spacer plans for all three RT modalities. Regarding post-spacer plans, D2 cc of the GI tract was significantly lower on C-ion RT plans and proton RT plans than on photon RT plans (C-ion vs photonp = 0.001, proton vs photonp = 0.002). However, there was no significant difference between C-ion RT plans and proton RT plans for D2 cc of the GI tract (C-ion vs protonp = 0.992). In the photon RT plan for one patient, D2 cc of the GI tract did not meet < 50 Gy.Conclusions: The GO spacer shows a significant dose reduction effect on the GI tract.
- 21 November 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-10
Open AccessIn silico comparison of the dosimetric impacts of a greater omentum spacer for abdominal and pelvic tumors in carbon-ion, proton and photon radiotherapy
Purpose: The purpose of this study was to compare carbon-ion (C-ion), proton and photon radiotherapy (RT) plans with regard to dose reduction of the gastrointestinal (GI) tract by using a greater omentum spacer (GO spacer).Methods: We retrospectively retrieved data for ten patients who received the GO spacer as surgical spacer placement for abdominal and pelvic tumors. Simulation plans were created on pre-spacer Computed Tomography (CT) and post-spacer CT for C-ion RT, proton RT and photon RT to compare the dose of the GI tract. The plans were normalized so that at least 95% of the planning target volume (PTV) received 70 Gy (relative biological effectiveness equivalent) delivered in 35 fractions. All plans were created with the lowest possible dose to the GI tract under conditions that meet the dose constraints for the PTV and spinal cord (maximum dose < 45 Gy). The part of the GI tract to be evaluated was defined as that most adjacent to the PTV. C-ion RT plans and proton RT plans were calculated by a spot scanning technique, and photon RT plans were calculated employing by fixed-field intensity-modulated radiation therapy.Results: D2 cc and V10–70 of the GI tract were significantly lower on post-spacer plans than on pre-spacer plans for all three RT modalities. Regarding post-spacer plans, D2 cc of the GI tract was significantly lower on C-ion RT plans and proton RT plans than on photon RT plans (C-ion vs photonp = 0.001, proton vs photonp = 0.002). However, there was no significant difference between C-ion RT plans and proton RT plans for D2 cc of the GI tract (C-ion vs protonp = 0.992). In the photon RT plan for one patient, D2 cc of the GI tract did not meet < 50 Gy.Conclusions: The GO spacer shows a significant dose reduction effect on the GI tract.
- Open Access
- 5 February 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 1-7
Clinical results of proton beam therapy for elderly patients with non-small cell lung cancer
The purpose of the present study was to evaluate retrospectively the efficacy and safety of proton beam therapy for elderly patients (≥80 years of age) with non-small cell lung cancer. Patients diagnosed with T1–4 N0 M0 non-small cell lung cancer and treated with proton beam therapy between January 2009 and 2015 were recruited from our database retrospectively. Toxicity was evaluated using The Common Terminology Criteria for Adverse Events version 4.0. Thirty-five patients, including 25 (71%) with clinically inoperable lung cancer, were administered proton beam therapy. The median age was 82 years (range: 80–87 years), and the median follow-up time was 34 months (range: 10–72 months). The median dose of proton beam therapy was 80.0 Gy relative biological effectiveness (RBE) (range: 60.0–80.0 Gy [RBE]), and all patients completed the treatments. All patients were followed for at least 23 months or until their death. The 3-year overall survival rate was 67.2% (90.0% in patients with operable lung cancer, and 58.2% in those with inoperable lung cancer). The 3-year local control rate was 86.5%. Two patients presented with grade 2 pneumonitis. The occurrence rate of grade 2 pneumonitis was significantly correlated with a high lung V20 (p = 0.030), and a high mean lung dose (p = 0.030), and a low ratio of lung volume spared from 0.05 Gy (RBE) dose (total lung volume minus lung volume irradiated at least 0.05 Gy [RBE]) (p = 0.030). However, there were no cases of grade 3 or higher radiation pneumonitis. This study suggests that the proton beam therapy was feasible for elderly patients with non-small cell lung cancer and can be considered as one of the treatment choices for elderly patients with lung cancer.
- 5 February 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 1-7
Open AccessClinical results of proton beam therapy for elderly patients with non-small cell lung cancer
The purpose of the present study was to evaluate retrospectively the efficacy and safety of proton beam therapy for elderly patients (≥80 years of age) with non-small cell lung cancer. Patients diagnosed with T1–4 N0 M0 non-small cell lung cancer and treated with proton beam therapy between January 2009 and 2015 were recruited from our database retrospectively. Toxicity was evaluated using The Common Terminology Criteria for Adverse Events version 4.0. Thirty-five patients, including 25 (71%) with clinically inoperable lung cancer, were administered proton beam therapy. The median age was 82 years (range: 80–87 years), and the median follow-up time was 34 months (range: 10–72 months). The median dose of proton beam therapy was 80.0 Gy relative biological effectiveness (RBE) (range: 60.0–80.0 Gy [RBE]), and all patients completed the treatments. All patients were followed for at least 23 months or until their death. The 3-year overall survival rate was 67.2% (90.0% in patients with operable lung cancer, and 58.2% in those with inoperable lung cancer). The 3-year local control rate was 86.5%. Two patients presented with grade 2 pneumonitis. The occurrence rate of grade 2 pneumonitis was significantly correlated with a high lung V20 (p = 0.030), and a high mean lung dose (p = 0.030), and a low ratio of lung volume spared from 0.05 Gy (RBE) dose (total lung volume minus lung volume irradiated at least 0.05 Gy [RBE]) (p = 0.030). However, there were no cases of grade 3 or higher radiation pneumonitis. This study suggests that the proton beam therapy was feasible for elderly patients with non-small cell lung cancer and can be considered as one of the treatment choices for elderly patients with lung cancer.
- 1 April 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1072) , 20160790
Dose escalation study with respiratory-gated carbon-ion scanning radiotherapy using a simultaneous integrated boost for pancreatic cancer: simulation with four-dimensional computed tomography
Objective:Pancreatic cancer is a difficult to treat disease with a persistently high mortality rate. We evaluated dose distribution simulation with respiratory-gated carbon-ion pencil beam scanning (C-PBS) with a simultaneous integrated boost (SIB) to increase tumour dose, sparing organs at risk (OARs).Methods:Using four-dimensional CT data of 12 patients, we delineated gross tumour volume and two clinical target volumes (CTVs). To consider beam range intrafractional uncertainty, we calculated field-specific target volumes, from which two planning target volumes (PTVs) were generated. PTV1 would receive a planned dose of 55.2 Gy [relative biological effectiveness (RBE)-weighted absorbed dose] in 12 fractions, and PTV2 would receive an SIB dose up to 67.2 Gy (RBE). Dose assessments were conducted with regard to the targets and OARs.Results:CTV2 dose covering 95% of the volume (D95%) increased from 50.3 ± 5.1 Gy (RBE) to 62.5 ± 3.5 Gy (RBE) for a planned dose from 55.2 Gy (RBE) to 67.2 Gy (RBE). For 4 of 12...
- 1 April 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1072) , 20160790
Dose escalation study with respiratory-gated carbon-ion scanning radiotherapy using a simultaneous integrated boost for pancreatic cancer: simulation with four-dimensional computed tomography
Objective:Pancreatic cancer is a difficult to treat disease with a persistently high mortality rate. We evaluated dose distribution simulation with respiratory-gated carbon-ion pencil beam scanning (C-PBS) with a simultaneous integrated boost (SIB) to increase tumour dose, sparing organs at risk (OARs).Methods:Using four-dimensional CT data of 12 patients, we delineated gross tumour volume and two clinical target volumes (CTVs). To consider beam range intrafractional uncertainty, we calculated field-specific target volumes, from which two planning target volumes (PTVs) were generated. PTV1 would receive a planned dose of 55.2 Gy [relative biological effectiveness (RBE)-weighted absorbed dose] in 12 fractions, and PTV2 would receive an SIB dose up to 67.2 Gy (RBE). Dose assessments were conducted with regard to the targets and OARs.Results:CTV2 dose covering 95% of the volume (D95%) increased from 50.3 ± 5.1 Gy (RBE) to 62.5 ± 3.5 Gy (RBE) for a planned dose from 55.2 Gy (RBE) to 67.2 Gy (RBE). For 4 of 12...