WWWei Wang

Wei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wei Wang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Haosu Luo

    Chinese Academy of Sciences 1 Key Laboratory of Inorganic Functional Material and Device, Shanghai Institute of Ceramics Shanghai 201800, China

    3 shared publications
  • Xiangyong Zhao

    Key Laboratory of Optoelectronic Material and Device, Department of Physics, Shanghai Normal University, Shanghai, China

    3 shared publications
  • Yaoyao Zhang

    Chinese Academy of Sciences 1 Key Laboratory of Inorganic Functional Material and Device, Shanghai Institute of Ceramics Shanghai 201800, China

    3 shared publications
  • Jie Jiao

    Chinese Academy of Sciences 1 Key Laboratory of Inorganic Functional Material and Device, Shanghai Institute of Ceramics Shanghai 201800, China

    2 shared publications
  • Bo Ren

    Chinese Academy of Sciences 1 Key Laboratory of Inorganic Functional Material and Device, Shanghai Institute of Ceramics 215 Chengbei Road, Jiading, Shanghai 201800, China

    1 shared publication
  • Chung Ming Leung

    The Hong Kong Polytechnic University 2 Department of Electrical Engineering Hung Hom, Kowloon, Hong Kong

    1 shared publication

Latest Publications

  • Open Access

    Fabrication of a PMN-PT Single Crystal-Based Transcranial Doppler Transducer and the Power Regulation of Its Detection System

    by Qingwen Yue, Dongxu Liu, Wei Wang, Wenning Di, Di Lin, Xi'An Wang, Haosu Luo

    Doppler sonographic measurement of flow velocity in the basal cerebral arteries through the intact skull was developed using a pulsed Doppler technique and 2 MHz emitting frequency. Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) were chosen to be the piezoelectric transducer material due to their ultrahigh piezoelectric coefficients, high electromechanical coupling coefficients and low dielectric loss. The pulse-echo response of the transducer was measured using the conventional pulse-echo method in a water bath at room temperature. The −6 dB bandwidth of the transducer is 68.4% and the sensitivity is −17.4 dB. In order to get a good match between transducer and detection system, different transmission powers have been regulated by changing the impedance of the transmitting electric circuit. In the middle cerebral artery (MCA) measurement photograph results, as the transmission power is increasing, the detection results become clearer and clearer. A comparison at the same transmission power for different transducers shows that the detection photograph obtained by the crystal transducer was clearer than that obtained with a commercial transducer, which should make it easier for doctors to find the cerebral arteries.


  • Broadband ultrasonic linear array using ternary PIN-PMN-PT single crystal

    by Wei Wang, Xiangyong Zhao, Siu Wing Or, Chung Ming Leung, Yaoyao Zhang, Jie Jiao, Haosu Luo

    Ternary Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) single crystal was investigated for potential application in ultrasonic linear array. Orientation and temperature dependences of height extensional electromechanical coupling coefficient k′33 for PIN-PMN-PT single crystal were studied. It was found that the [001] poled PIN-PMN-PT diced along the [100] direction would achieve a maximum k′33 (∼87%) and the service temperature was up to 110 °C. Ultrasonic linear arrays using PIN-PMN-PT single crystal and PZT ceramic were fabricated and compared. The bandwidth at −6 dB, two-way insertion loss and pulse length of the PIN-PMN-PT array were 98.6%, −45.1 dB, and 0.28 μs, respectively, which were about 25% broader, 3.7dB higher, and 0.08 μs shorter than those of the PZT array. The experimental results agreed well with the theoretical simulation. These superior performances were attributable to the excellent piezoelectric properties of PIN-PMN-PT single crystal.


  • Shear-mode piezoelectric properties of ternary Pb(In1/2Nb1/2)O3–Pb(Mg1/3Nb2/3)O3–PbTiO3 single crystals

    by Wei Wang, Da'AN Liu, Qinhui Zhang, Bo Ren, Yaoyao Zhang, Jie Jiao, Di Lin, Xiangyong Zhao, Haosu Luo

    A systematic study of the optimized orientation and temperature dependence of shear-mode piezoelectric properties for ternary Pb(In1/2Nb1/2)O3–Pb(Mg1/3Nb2/3)O3–PbTiO3 (PIN–PMN–PT or PIMNT) piezocrystals was carried out. It was found that [111]-poled samples presented the best shear piezoelectric properties when driving along [11¯0] (the thickness direction). The electromechanical coupling coefficient k15 and piezoelectric coefficient d15 and g15 were found to be 96.4%, 5966 pC/N, and 0.047 Vm/N, respectively, for optimum-cut samples with platinum (Pt) electrode. Besides, the maximum service temperature for shear mode is around 105 °C , which is much higher than PMNT single crystals.