Frank Nagl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Frank Nagl has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Andreas Schuessler
ADMEDES Schuessler GmbH
1 shared publicationGerd Siekmeyer
Acandis GmbH & Co. KG
1 shared publication- Joachim Berkefeld
Johann Wolfgang Goethe-Universität Frankfurt
1 shared publication - Katharina Wenger
Department of Neuroradiology, Johann Wolfgang Goethe University, Schleusenweg 2-16, Haus 95, 60528, Frankfurt am Main, Germany,
1 shared publication - Marlies Wagner
Institute of Neuroradiology, University Hospital Frankfurt, Goethe-University, 60528 Frankfurt am Main, Germany
1 shared publication Michael Quellmalz
Acandis GmbH & Co. KG
1 shared publication
Latest Publications
- 15 June 2012
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (1) , 192-197
Improvement of Stent Retriever Design and Efficacy of Mechanical Thrombectomy in a Flow Model
Purpose In vitro experiments were performed to evaluate the efficacy of mechanical intracranial thrombectomy comparing the newly developed Aperio stent retriever and standard devices for stroke treatment. Methods The Aperio (A), with an increased working length of 4 cm and a special cell design for capturing and withholding clots, was compared to three benchmark devices: the Solitaire retrievable stent (B), the Merci X6 (C), and the Merci L5 retriever (D). In a vascular glass model with pulsatile flow, reminiscent of the M1 segment of the middle cerebral artery, we repeatedly induced occlusion by generating thrombi via a modified Chandler loop system. The numbers of recanalization attempts, peripheral embolizations, and recanalizations at the site of occlusion were recorded during 10 retrieval experiments with each device. Results Eleven devices were able to remove the blood clots from the occluded branch. In 34 of 40 experiments, restoration of flow was obtained in 1–3 attempts. The main differences between the study devices were observed in terms of clot withholding and fragmentation during retrieval. Although there was only one fragmentation recorded for device A, disengagement of the whole clot or peripheral embolization of fragments occurred more frequently (5–7 times) with devices B, C, and D. Conclusion In a vascular model, the design of device A was best at capturing and withholding thrombi during retrieval. Further study will be necessary to see whether this holds true in clinical applications.
- 15 June 2012
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (1) , 192-197
Improvement of Stent Retriever Design and Efficacy of Mechanical Thrombectomy in a Flow Model
Purpose In vitro experiments were performed to evaluate the efficacy of mechanical intracranial thrombectomy comparing the newly developed Aperio stent retriever and standard devices for stroke treatment. Methods The Aperio (A), with an increased working length of 4 cm and a special cell design for capturing and withholding clots, was compared to three benchmark devices: the Solitaire retrievable stent (B), the Merci X6 (C), and the Merci L5 retriever (D). In a vascular glass model with pulsatile flow, reminiscent of the M1 segment of the middle cerebral artery, we repeatedly induced occlusion by generating thrombi via a modified Chandler loop system. The numbers of recanalization attempts, peripheral embolizations, and recanalizations at the site of occlusion were recorded during 10 retrieval experiments with each device. Results Eleven devices were able to remove the blood clots from the occluded branch. In 34 of 40 experiments, restoration of flow was obtained in 1–3 attempts. The main differences between the study devices were observed in terms of clot withholding and fragmentation during retrieval. Although there was only one fragmentation recorded for device A, disengagement of the whole clot or peripheral embolization of fragments occurred more frequently (5–7 times) with devices B, C, and D. Conclusion In a vascular model, the design of device A was best at capturing and withholding thrombi during retrieval. Further study will be necessary to see whether this holds true in clinical applications.
- 1 July 2011
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 20 (4-5) , 737-744
A Comparison of Different Nitinol Material Data Sources for Finite Element Analysis
- 1 July 2011
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 20 (4-5) , 737-744
A Comparison of Different Nitinol Material Data Sources for Finite Element Analysis