Cristian Arzola
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Cristian Arzola has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
A. Perlas
Department of Anesthesia and Pain Management, Mount Sinai Hospital, University of Toronto, Toronto, ON, Canada
3 shared publicationsK. Downey
3 shared publicationsJ. Cubillos
Department of Anesthesia and Pain Management, Mount Sinai Hospital, University of Toronto, Toronto, ON, Canada
2 shared publicationsJ.C. Carvalho
Department of Anesthesia and Pain Management, Mount Sinai Hospital, University of Toronto, Toronto, ON, Canada
2 shared publicationsAnahi Perlas
University Health Network and University of Toronto
1 shared publicationJ. C. A. Carvalho
Department of Anesthesia and Pain Management, Mount Sinai Hospital, University of Toronto, 600 University Avenue, Room 19-104, Toronto, ON, Canada M5G 1X5
1 shared publication
Latest Publications
- 1 December 2018
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 38 (4) , 223
Lumbar Spine Anatomy in Women Sustaining Unintentional Dural Puncture During Labor Epidural Placement: A Descriptive Study Using Magnetic Resonance Imaging and Ultrasound
(Reg Anesth Pain Med. 2018;43:92–96) Unintentional puncture of the dura mater is one of the most common complications of epidural catheter placement and can result in a postdural puncture headache. The incidence of this complication has remained unchanged and efforts to identify patient risk factors have been unsuccessful. There has not been success in identifying risk factors for this complication. A retrospective study showed there was a higher risk of atypical sonoanatomy of the ligamentum flavum/dura mater unit among women who experienced unintentional dural puncture during epidural placement compared with a control group. It was not clear whether this was a limitation of ultrasound imaging or a representation of abnormal anatomy. The objectives of this study were to assess for abnormal lumbar anatomy in women sustaining unintentional dural punctures during labor epidural placement utilizing magnetic resonance imaging (MRI) and ultrasound.
- 1 December 2018
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 38 (4) , 223
Lumbar Spine Anatomy in Women Sustaining Unintentional Dural Puncture During Labor Epidural Placement: A Descriptive Study Using Magnetic Resonance Imaging and Ultrasound
(Reg Anesth Pain Med. 2018;43:92–96) Unintentional puncture of the dura mater is one of the most common complications of epidural catheter placement and can result in a postdural puncture headache. The incidence of this complication has remained unchanged and efforts to identify patient risk factors have been unsuccessful. There has not been success in identifying risk factors for this complication. A retrospective study showed there was a higher risk of atypical sonoanatomy of the ligamentum flavum/dura mater unit among women who experienced unintentional dural puncture during epidural placement compared with a control group. It was not clear whether this was a limitation of ultrasound imaging or a representation of abnormal anatomy. The objectives of this study were to assess for abnormal lumbar anatomy in women sustaining unintentional dural punctures during labor epidural placement utilizing magnetic resonance imaging (MRI) and ultrasound.
- 1 September 2016
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 36 (3) , 146-147
Bedside Gastric Ultrasonography in Term Pregnant Women Before Elective Cesarean Delivery: A Prospective Cohort Study
(Anesth Analg. 2015;121:752–758) Bedside ultrasonography can be used to establish the gastric contents of pregnant women about to undergo general anesthesia for elective cesarean delivery. This could help avoid the serious complication of pulmonary aspiration by prompting anesthesiologists to discourage general anesthesia in a woman found to have a full stomach. In the past ultrasonography was not able to detect an empty stomach, but technological improvements have made this a possibility. This study investigated the qualitative and quantitative sonographic patterns of the gastric antrum in fasted pregnant patients.
- 1 September 2016
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 36 (3) , 146-147
Bedside Gastric Ultrasonography in Term Pregnant Women Before Elective Cesarean Delivery: A Prospective Cohort Study
(Anesth Analg. 2015;121:752–758) Bedside ultrasonography can be used to establish the gastric contents of pregnant women about to undergo general anesthesia for elective cesarean delivery. This could help avoid the serious complication of pulmonary aspiration by prompting anesthesiologists to discourage general anesthesia in a woman found to have a full stomach. In the past ultrasonography was not able to detect an empty stomach, but technological improvements have made this a possibility. This study investigated the qualitative and quantitative sonographic patterns of the gastric antrum in fasted pregnant patients.
- 1 December 2015
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 35 (4) , 200-201
Interrater Reliability of Qualitative Ultrasound Assessment of Gastric Content in the Third Trimester of Pregnancy
(Br J Anaesth. 2014;113(6):1018–1023)
- 1 December 2015
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 35 (4) , 200-201
Interrater Reliability of Qualitative Ultrasound Assessment of Gastric Content in the Third Trimester of Pregnancy
(Br J Anaesth. 2014;113(6):1018–1023)
- 1 January 2015
- Published by Sociedad Colombiana de Anestesiologia y Reanimacion (SCARE) in Colombian Journal of Anesthesiology
- Vol. 43 (4) , 261-262
Point-of-care ultrasonography for anesthesiologists☆
- 1 January 2015
- Published by Sociedad Colombiana de Anestesiologia y Reanimacion (SCARE) in Colombian Journal of Anesthesiology
- Vol. 43 (4) , 261-262
Point-of-care ultrasonography for anesthesiologists☆
- Open Access
- 30 July 2014
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 113 (6) , 1018-1023
Interrater reliability of qualitative ultrasound assessment of gastric content in the third trimester of pregnancy
Pulmonary aspiration of gastric contents in pregnant women undergoing general anaesthesia is one of the most feared complications in obstetric anaesthesia. Bedside gastric ultrasonography is a feasible imaging tool to assess the gastric content. The purpose of this study was to investigate the reliability of qualitative bedside assessment of the gastric content performed by anaesthesiologists on third trimester pregnant women. Pregnant women (≥32 weeks gestational age) were randomized to undergo ultrasound (US) assessments of their stomach in a fasting state (>8 h), or after ingestion of clear fluids only, or solid food. Three anaesthesiologists trained in gastric ultrasonography performed the assessments using a low-frequency curved-array US transducer (5–2 MHz). Primary outcome of the study was the consistency of raters in diagnosing the correct status of the gastric content, which was used to determine the interrater reliability among the three anaesthesiologists. Secondary outcomes were overall proportion of correct and incorrect diagnoses and the specific proportions of correct diagnosis across the three gastric content groups. We analysed 32 pregnant women. The interrater reliability displayed a kappa statistic of 0.74 (bias corrected 95% CI: 0.68–0.84). The overall proportion of correct diagnosis was 87.5% (84 of 96). The odds of correct diagnosis for ‘solid contents’ were 16.7 times the odds for ‘empty’, and 14.3 times for ‘clear fluid’. Our results show the consistency of the qualitative US assessment of gastric contents of pregnant women in the third trimester by anaesthesiologists. A kappa of 0.74 suggests substantial agreement in terms of interrater reliability for this diagnostic measurement. ClinicalTrials.gov identifier: NCT01564030.
- 30 July 2014
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 113 (6) , 1018-1023
Open AccessInterrater reliability of qualitative ultrasound assessment of gastric content in the third trimester of pregnancy
Pulmonary aspiration of gastric contents in pregnant women undergoing general anaesthesia is one of the most feared complications in obstetric anaesthesia. Bedside gastric ultrasonography is a feasible imaging tool to assess the gastric content. The purpose of this study was to investigate the reliability of qualitative bedside assessment of the gastric content performed by anaesthesiologists on third trimester pregnant women. Pregnant women (≥32 weeks gestational age) were randomized to undergo ultrasound (US) assessments of their stomach in a fasting state (>8 h), or after ingestion of clear fluids only, or solid food. Three anaesthesiologists trained in gastric ultrasonography performed the assessments using a low-frequency curved-array US transducer (5–2 MHz). Primary outcome of the study was the consistency of raters in diagnosing the correct status of the gastric content, which was used to determine the interrater reliability among the three anaesthesiologists. Secondary outcomes were overall proportion of correct and incorrect diagnoses and the specific proportions of correct diagnosis across the three gastric content groups. We analysed 32 pregnant women. The interrater reliability displayed a kappa statistic of 0.74 (bias corrected 95% CI: 0.68–0.84). The overall proportion of correct diagnosis was 87.5% (84 of 96). The odds of correct diagnosis for ‘solid contents’ were 16.7 times the odds for ‘empty’, and 14.3 times for ‘clear fluid’. Our results show the consistency of the qualitative US assessment of gastric contents of pregnant women in the third trimester by anaesthesiologists. A kappa of 0.74 suggests substantial agreement in terms of interrater reliability for this diagnostic measurement. ClinicalTrials.gov identifier: NCT01564030.
- 24 May 2013
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 60 (8) , 771-779
Anesthesiologists’ learning curves for bedside qualitative ultrasound assessment of gastric content: a cohort study
Focused assessment of the gastric antrum by ultrasound is a feasible tool to evaluate the quality of the stomach content. We aimed to determine the amount of training an anesthesiologist would need to achieve competence in the bedside ultrasound technique for qualitative assessment of gastric content.
- 24 May 2013
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 60 (8) , 771-779
Anesthesiologists’ learning curves for bedside qualitative ultrasound assessment of gastric content: a cohort study
Focused assessment of the gastric antrum by ultrasound is a feasible tool to evaluate the quality of the stomach content. We aimed to determine the amount of training an anesthesiologist would need to achieve competence in the bedside ultrasound technique for qualitative assessment of gastric content.
- 1 September 2012
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 32 (3) , 194-195
Efficacy of Low-dose Bupivacaine in Spinal Anesthesia for Cesarean Delivery
- 1 September 2012
- Published by Wolters Kluwer Health in Obstetric Anesthesia Digest
- Vol. 32 (3) , 194-195
Efficacy of Low-dose Bupivacaine in Spinal Anesthesia for Cesarean Delivery
- 5 October 2011
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 58 (12) , 1069-1074
Identification of cervicothoracic intervertebral spaces by surface landmarks and ultrasound
Precise localization of the cervicothoracic vertebral levels is essential for accurate placement of epidural catheters. Previous studies have demonstrated that anesthesiologists are inaccurate when using surface anatomy to locate lumbar vertebral levels. Our study was designed to determine the agreement between anatomical landmarks and the ultrasound technique in identifying the T7-8 and C7-T1 intervertebral spaces. Adult healthy volunteers were assessed for the identification of cervicothoracic intervertebral spaces, initially in the anatomic position (AP)—upright, back straight, arms at the sides, and palms forward and then in the epidural position (EP) routinely used for epidural placement—seated, back arched, neck flexed, and arms across the chest. The T7 and C7 spinous processes were identified by one investigator using the inferior tip of the scapula and the vertebra prominens, respectively, as landmarks. Ultrasound was then used by a second investigator to identify the intervertebral spaces corresponding to the previously marked levels. Fifty-five volunteers (23 males, 32 females) were recruited. The T7-8 intervertebral space determined by ultrasound coincided with the landmark findings in the AP and in the EP in 18% and 36% of the cases, respectively. The C7-T1 interspace identified by ultrasound corresponded with the surface landmarks in the AP and in the EP in 53% and 58% of the cases, respectively. In most cases, when the surface landmark and ultrasound findings of T7-8 did not agree, the surface landmark identified a lower interspace than ultrasound. Identification of cervicothoracic intervertebral spaces by surface landmarks corresponded poorly with their identification using ultrasound. However, compared with the upright position, agreement in identifying the T7-8 interspace improved in the epidural position. La localisation précise des niveaux vertébraux cervicothoraciques est cruciale pour positionner de façon précise les cathéters périduraux. Des études ont précédemment démontré que les anesthésiologistes sont peu précis lorsqu’ils se servent des repères anatomiques pour localiser les niveaux vertébraux lombaires. Notre étude a été conçue afin de déterminer la correspondance des résultats obtenus en se fondant sur des repères anatomiques ou une technique par échographie pour déterminer l’emplacement des espaces intervertébraux T7-8 et C7-T1. Des volontaires sains adultes ont été évalués afin de déterminer l’emplacement des espaces intervertébraux cervicothoraciques, d’abord en position anatomique (PA) – soit debout, le dos droit, les bras le long du corps et les paumes vers l’avant, puis en position péridurale (PP), communément utilisée pour l’installation des péridurales – soit assis, le dos cambré, le cou fléchi et les bras croisés devant la poitrine. Les apophyses épineuses T7 et C7 ont été identifiées par un chercheur qui s’est servi de la pointe inférieure de l’omoplate et de la septième vertèbre cervicale (vertèbre proéminente), respectivement, comme repères. Un deuxième chercheur s’est ensuite servi de l’échographie pour déterminer l’emplacement des espaces intervertébraux correspondant aux niveaux précédemment marqués. Cinquante-cinq volontaires (23 hommes, 32 femmes) ont été recrutés. L’espace intervertébral T7-8 déterminé par échographie correspondait à l’espace déterminé par repère anatomique en PA et en PP dans 18 % et 36 % des cas, respectivement. L’espace intervertébral C7-T1 tel que déterminé par échographie correspondait à celui déterminé par repère anatomique en PA et en PP dans 53 % et 58 % des cas, respectivement. Dans la plupart des cas, lorsque les repères anatomiques et les résultats par échographie ne correspondaient pas au niveau T7-8, le repère anatomique avait identifié un espace intervertébral plus bas que l’échographie. La détermination de l’emplacement des espaces intervertébraux cervicothoraciques par des repères anatomiques correspond mal à leur localisation à l’aide de l’échographie. Toutefois, il existe une meilleure correspondance entre les deux techniques pour l’espace intervertébral T7-8 en position péridurale qu’en position anatomique.
- 5 October 2011
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 58 (12) , 1069-1074
Identification of cervicothoracic intervertebral spaces by surface landmarks and ultrasound
Precise localization of the cervicothoracic vertebral levels is essential for accurate placement of epidural catheters. Previous studies have demonstrated that anesthesiologists are inaccurate when using surface anatomy to locate lumbar vertebral levels. Our study was designed to determine the agreement between anatomical landmarks and the ultrasound technique in identifying the T7-8 and C7-T1 intervertebral spaces. Adult healthy volunteers were assessed for the identification of cervicothoracic intervertebral spaces, initially in the anatomic position (AP)—upright, back straight, arms at the sides, and palms forward and then in the epidural position (EP) routinely used for epidural placement—seated, back arched, neck flexed, and arms across the chest. The T7 and C7 spinous processes were identified by one investigator using the inferior tip of the scapula and the vertebra prominens, respectively, as landmarks. Ultrasound was then used by a second investigator to identify the intervertebral spaces corresponding to the previously marked levels. Fifty-five volunteers (23 males, 32 females) were recruited. The T7-8 intervertebral space determined by ultrasound coincided with the landmark findings in the AP and in the EP in 18% and 36% of the cases, respectively. The C7-T1 interspace identified by ultrasound corresponded with the surface landmarks in the AP and in the EP in 53% and 58% of the cases, respectively. In most cases, when the surface landmark and ultrasound findings of T7-8 did not agree, the surface landmark identified a lower interspace than ultrasound. Identification of cervicothoracic intervertebral spaces by surface landmarks corresponded poorly with their identification using ultrasound. However, compared with the upright position, agreement in identifying the T7-8 interspace improved in the epidural position. La localisation précise des niveaux vertébraux cervicothoraciques est cruciale pour positionner de façon précise les cathéters périduraux. Des études ont précédemment démontré que les anesthésiologistes sont peu précis lorsqu’ils se servent des repères anatomiques pour localiser les niveaux vertébraux lombaires. Notre étude a été conçue afin de déterminer la correspondance des résultats obtenus en se fondant sur des repères anatomiques ou une technique par échographie pour déterminer l’emplacement des espaces intervertébraux T7-8 et C7-T1. Des volontaires sains adultes ont été évalués afin de déterminer l’emplacement des espaces intervertébraux cervicothoraciques, d’abord en position anatomique (PA) – soit debout, le dos droit, les bras le long du corps et les paumes vers l’avant, puis en position péridurale (PP), communément utilisée pour l’installation des péridurales – soit assis, le dos cambré, le cou fléchi et les bras croisés devant la poitrine. Les apophyses épineuses T7 et C7 ont été identifiées par un chercheur qui s’est servi de la pointe inférieure de l’omoplate et de la septième vertèbre cervicale (vertèbre proéminente), respectivement, comme repères. Un deuxième chercheur s’est ensuite servi de l’échographie pour déterminer l’emplacement des espaces intervertébraux correspondant aux niveaux précédemment marqués. Cinquante-cinq volontaires (23 hommes, 32 femmes) ont été recrutés. L’espace intervertébral T7-8 déterminé par échographie correspondait à l’espace déterminé par repère anatomique en PA et en PP dans 18 % et 36 % des cas, respectivement. L’espace intervertébral C7-T1 tel que déterminé par échographie correspondait à celui déterminé par repère anatomique en PA et en PP dans 53 % et 58 % des cas, respectivement. Dans la plupart des cas, lorsque les repères anatomiques et les résultats par échographie ne correspondaient pas au niveau T7-8, le repère anatomique avait identifié un espace intervertébral plus bas que l’échographie. La détermination de l’emplacement des espaces intervertébraux cervicothoraciques par des repères anatomiques correspond mal à leur localisation à l’aide de l’échographie. Toutefois, il existe une meilleure correspondance entre les deux techniques pour l’espace intervertébral T7-8 en position péridurale qu’en position anatomique.
- Open Access
- 14 July 2011
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 107 (3) , 308-318
Efficacy of low-dose bupivacaine in spinal anaesthesia for Caesarean delivery: systematic review and meta-analysis
Spinal anaesthesia is the preferred anaesthetic technique for elective Caesarean deliveries. Hypotension is the most common side-effect and has both maternal and neonatal consequences. Different strategies have been attempted to prevent spinal-induced hypotension, including the use of low-dose bupivacaine. We conducted a systematic search for randomized controlled trials comparing the efficacy of spinal bupivacaine in low dose (LD ≤8 mg) with conventional dose (CD >8 mg) for elective Caesarean delivery. Thirty-five trials were identified for eligibility assessment, 15 were selected for data extraction, and 12 were finally included in the meta-analysis. We investigated sources of heterogeneity, subgroup analysis, and meta-regression for confounding variables (baricity, intrathecal opioids, lateral vs sitting position, uterine exteriorization, and study population). Sensitivity analysis was performed to test the robustness of the results. In the LD group, the need for analgesic supplementation during surgery was significantly higher [risk ratio (RR)=3.76, 95% confidence interval (95% CI)=2.38–5.92] and the number needed to treat for an additional harmful outcome (NNTH) was 4 (95% CI=2–7). Furthermore, the LD group exhibited a lower risk of hypotension (RR=0.78, 95% CI=0.65–0.93) and nausea/vomiting (RR=0.71, 95% CI=0.55–0.93). Conversion to general anaesthesia occurred only in the LD group (two events). Neonatal outcomes (Apgar score, acid–base status) and clinical quality variables (patient satisfaction, surgical conditions) showed non-significant differences between LD and CD. This meta-analysis demonstrates that low-dose bupivacaine in spinal anaesthesia compromises anaesthetic efficacy (risk of analgesic supplementation: high grade of evidence), despite the benefit of lower maternal side-effects (hypotension, nausea/vomiting: moderate grade of evidence).
- 14 July 2011
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 107 (3) , 308-318
Open AccessEfficacy of low-dose bupivacaine in spinal anaesthesia for Caesarean delivery: systematic review and meta-analysis
Spinal anaesthesia is the preferred anaesthetic technique for elective Caesarean deliveries. Hypotension is the most common side-effect and has both maternal and neonatal consequences. Different strategies have been attempted to prevent spinal-induced hypotension, including the use of low-dose bupivacaine. We conducted a systematic search for randomized controlled trials comparing the efficacy of spinal bupivacaine in low dose (LD ≤8 mg) with conventional dose (CD >8 mg) for elective Caesarean delivery. Thirty-five trials were identified for eligibility assessment, 15 were selected for data extraction, and 12 were finally included in the meta-analysis. We investigated sources of heterogeneity, subgroup analysis, and meta-regression for confounding variables (baricity, intrathecal opioids, lateral vs sitting position, uterine exteriorization, and study population). Sensitivity analysis was performed to test the robustness of the results. In the LD group, the need for analgesic supplementation during surgery was significantly higher [risk ratio (RR)=3.76, 95% confidence interval (95% CI)=2.38–5.92] and the number needed to treat for an additional harmful outcome (NNTH) was 4 (95% CI=2–7). Furthermore, the LD group exhibited a lower risk of hypotension (RR=0.78, 95% CI=0.65–0.93) and nausea/vomiting (RR=0.71, 95% CI=0.55–0.93). Conversion to general anaesthesia occurred only in the LD group (two events). Neonatal outcomes (Apgar score, acid–base status) and clinical quality variables (patient satisfaction, surgical conditions) showed non-significant differences between LD and CD. This meta-analysis demonstrates that low-dose bupivacaine in spinal anaesthesia compromises anaesthetic efficacy (risk of analgesic supplementation: high grade of evidence), despite the benefit of lower maternal side-effects (hypotension, nausea/vomiting: moderate grade of evidence).