JKJuha M. Kortelainen

Juha M. Kortelainen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Juha M. Kortelainen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multi-Scale Evaluation of Sleep Quality Based on Motion Signal from Unobtrusive Device

    by Davide Coluzzi, Giuseppe Baselli, Anna Maria Bianchi, Guillermina Guerrero-Mora, Juha M. Kortelainen, Mirja L. Tenhunen, Martin O. Mendez

    Sleep disorders are a growing threat nowadays as they are linked to neurological, cardiovascular and metabolic diseases. The gold standard methodology for sleep study is polysomnography (PSG), an intrusive and onerous technique that can disrupt normal routines. In this perspective, m-Health technologies offer an unobtrusive and rapid solution for home monitoring. We developed a multi-scale method based on motion signal extracted from an unobtrusive device to evaluate sleep behavior. Data used in this study were collected during two different acquisition campaigns by using a Pressure Bed Sensor (PBS). The first one was carried out with 22 subjects for sleep problems, and the second one comprises 11 healthy shift workers. All underwent full PSG and PBS recordings. The algorithm consists of extracting sleep quality and fragmentation indexes correlating to clinical metrics. In particular, the method classifies sleep windows of 1-s of the motion signal into: displacement (DI), quiet sleep (QS), disrupted sleep (DS) and absence from the bed (ABS). QS proved to be positively correlated (0.72±0.014) to Sleep Efficiency (SE) and DS/DI positively correlated (0.85±0.007) to the Apnea-Hypopnea Index (AHI). The work proved to be potentially helpful in the early investigation of sleep in the home environment. The minimized intrusiveness of the device together with a low complexity and good performance might provide valuable indications for the home monitoring of sleep disorders and for subjects’ awareness.


  • Open Access

    Vital Sign Monitoring Using FMCW Radar in Various Sleeping Scenarios

    by Emmi Turppa, Juha M. Kortelainen, Oleg Antropov, Tero Kiuru

    Remote monitoring of vital signs for studying sleep is a user-friendly alternative to monitoring with sensors attached to the skin. For instance, remote monitoring can allow unconstrained movement during sleep, whereas detectors requiring a physical contact may detach and interrupt the measurement and affect sleep itself. This study evaluates the performance of a cost-effective frequency modulated continuous wave (FMCW) radar in remote monitoring of heart rate and respiration in scenarios resembling a set of normal and abnormal physiological conditions during sleep. We evaluate the vital signs of ten subjects in different lying positions during various tasks. Specifically, we aim for a broad range of both heart and respiration rates to replicate various real-life scenarios and to test the robustness of the selected vital sign extraction methods consisting of fast Fourier transform based cepstral and autocorrelation analyses. As compared to the reference signals obtained using Embla titanium, a certified medical device, we achieved an overall relative mean absolute error of 3.6% (86% correlation) and 9.1% (91% correlation) for the heart rate and respiration rate, respectively. Our results promote radar-based clinical monitoring by showing that the proposed radar technology and signal processing methods accurately capture even such alarming vital signs as minimal respiration. Furthermore, we show that common parameters for heart rate variability can also be accurately extracted from the radar signal, enabling further sleep analyses.


  • Sleep Staging Based on Signals Acquired Through Bed Sensor

    by Juha M. Kortelainen, Martin O Mendez, Anna Maria Bianchi, Matteo Matteucci, Sergio Cerutti

    We describe a system for the evaluation of the sleep macrostructure on the basis of Emfit sensor foils placed into bed mattress and of advanced signal processing. The signals on which the analysis is based are heart-beat interval (HBI) and movement activity obtained from the bed sensor, the relevant features and parameters obtained through a time-variant autoregressive model (TVAM) used as feature extractor, and the classification obtained through a hidden Markov model (HMM). Parameters coming from the joint probability of the HBI features were used as input to a HMM, while movement features are used for wake period detection. A total of 18 recordings from healthy subjects, including also reference polysomnography, were used for the validation of the system. When compared to wake-nonrapid-eye-movement (NREM)-REM classification provided by experts, the described system achieved a total accuracy of 79±9% and a kappa index of 0.43±0.17 with only two HBI features and one movement parameter, and a total accuracy of 79±10% and a kappa index of 0.44±0.19 with three HBI features and one movement parameter. These results suggest that the combination of HBI and movement features could be a suitable alternative for sleep staging with the advantage of low cost and simplicity.


  • FFT averaging of multichannel BCG signals from bed mattress sensor to improve estimation of heart beat interval

    by Juha M. Kortelainen, Jussi Virkkala

    A multichannel pressure sensing Emfit foil was integrated to a bed mattress for measuring ballistocardiograph signals during sleep. We calculated the heart beat interval with cepstrum method, by applying FFT for short time windows including pair of consequent heart beats. We decreased the variance of FFT by averaging the multichannel data in the frequency domain. Relative error of our method in reference to electrocardiograph RR interval was only 0.35% for 15 night recordings with six normal subjects, when 12% of data was automatically removed due to movement artifacts. Background motivation for this work is given from the studies applying heart rate variability for the sleep staging.