RCR. K. Choudhury

R. K. Choudhury

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


R. K. Choudhury has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Threshold anomaly in the elastic scattering of the weakly bound projectile 7Li on the medium-mass target 116Sn

    by N. N. Deshmukh, S. Mukherjee, B. K. Nayak, D. C. Biswas, S. Santra, S. Appannababu, E. T. Mirgule, A. Saxena, D. Patel, R. K. Choudhury, et al.

    Elastic scattering angular distributions using the weakly bound projectile 7Li on medium-mass target 116Sn were measured for 10 different beam energies from much below to above the Coulomb barrier. Optical model (OM) analysis was carried out using the famous double folding São Paulo Potential (SPP) to investigate the energy dependence of the interacting polarizing potentials. The absence of the usual Threshold Anomaly (TA) is observed. Thus this unusual behavior of the interacting potentials indicates the coupling of the breakup channels with the elastic ones.


  • Systematic study of projectile-structure effect on the fusion-barrier distribution

    by Pratap Roy, A. Saxena, B. K. Nayak, E. T. Mirgule, B. John, Y. K. Gupta, L. S. Danu, R. P. Vind, Ashok Kumar, R. K. Choudhury

    Quasielastic excitation function measurement has been carried out for the 4He + 232Th system at θlab=160∘ with respect to the beam direction, to obtain a representation of the fusion-barrier distribution. Using the present data along with previously measured barrier distribution results on 12C, 16O, and 19F + 232Th systems, a systematic analysis has been carried out to investigate the role of target and/or projectile structures on fusion-barrier distribution. It is observed that for 4He, 12C, and 16O + 232Th reactions, the couplings due to target states only are required in coupled-channel fusion calculations to explain the experimental data, whereas for the 19F + 232Th system along with the coupling of target states, inelastic states of 19F are also required to explain the experimental results on fusion-barrier distribution. The width of the barrier distribution shows interesting transition behavior when plotted with respect to the target-projectile charge product for the above systems. DOI: http://dx.doi.org/10.1103/PhysRevC.84.011602 ©2011 American Physical Society


  • Quasi-elastic scattering in theLi6+Th232reaction

    by S. Mukherjee, B. K. Nayak, D. S. Monteiro, J. Lubian, P. R. S. Gomes, S. Appannababu, R. K. Choudhury

    Quasi-elastic scattering measurements at large backward angles have been carried out for the Li6+Th232 system at energies around the Coulomb barrier. Barrier distribution has been obtained from the excitation function data. Coupled channel calculations using a double-folding potential as the bare potential have been performed. The disagreement between data and theoretical predictions shows a large breakup effect in the quasi-elastic scattering of a weakly bound projectile on a deformed target.


  • Ballistic Deficits for Ionization Chamber Pulses in Pulse Shaping Amplifiers

    by G. Anil Kumar, S. L. Sharma, R. K. Choudhury

    In order to understand the dependence of the ballistic deficit on the shape of rising portion of the voltage pulse at the input of a pulse shaping amplifier, we have estimated the ballistic deficits for the pulses from a two-electrode parallel plate ionization chamber as well as for the pulses from a gridded parallel plate ionization chamber. These estimations have been made using numerical integration method when the pulses are processed through the CR-RCn (n=1-6) shaping network as well as when the pulses are processed through the complex shaping network of the ORTEC Model 472 spectroscopic amplifier. Further, we have made simulations to see the effect of ballistic deficit on the pulse-height spectra under different conditions. We have also carried out measurements of the ballistic deficits for the pulses from a two-electrode parallel plate ionization chamber as well as for the pulses from a gridded parallel plate ionization chamber when these pulses are processed through the ORTEC 572 linear amplifier having a simple CR-RC shaping network. The reasonable matching of the simulated ballistic deficits with the experimental ballistic deficits for the CR-RC shaping network clearly establishes the validity of the simulation technique


  • Elimination of Ballistic Deficits for Ionization Chamber Pulses by using Trapezoidal Pulse shaper

    by G.A. Kumar, S. L. Sharma, D. C. Biswas, R. K. Choudhury, G. AnilKumar

    In a typical charged particle spectrometer employing charge sensitive preamplifier, the ballistic deficits can noticeably reduce the resolution of spectrometer when the pulse shaping networks produce short pulses with sharp peaks. Recently, it has been demonstrated that the effect of ballistic deficit can be eliminated by using flat-topped shapes. We have made simulation of the voltage pulses from the two-electrode parallel plate ionization chamber as well as pulses from the gridded parallel plate ionization chamber for heavy ions in order to understand the importance of flat-topped shapes in eliminating the effect of ballistic deficit. These detector pulses have been processed through preamplifier and CR-differentiator having pole-zero cancellation followed by a combination of rectangular and truncated ramp shaping network. The simulations of the voltage pulses have been made using numerical integration method for different angles the heavy ion track makes with the electric field. The simulations clearly show that the dependence of ballistic deficit on the angle of the charged particle track with electric field can be made negligibly small by using trapezoidal pulse shaper.

  • Large Pulse-Height Loss due to Capacitive Decay in the Detector-Circuit During Collection of Charges

    by S. L. Sharma, G. Anil Kumar, D. C. Biswas, R. K. Choudhury

    Ionization chambers produce voltage pulses across the load having rise-time characteristics dependent upon the electron transport. During the rise-time of a pulse, the effect of the capacitive decay in the detector-circuit during charge collection on the pulse-height is invariably ignored. This is quite reasonable as long as the detector-circuit time constant is appreciably large compared to the collection time of electrons. In a real situation, however, the capacitive decay can be very important. In order to understand the effect of capacitive decay in the detector-circuit during collection of charges on the pulse shapes and pulse-height spectra, we have recently made Monte Carlo simulations of the response of two-electrode parallel plate ionization chamber and gridded parallel plate ionization chamber for energetic heavy ions. Simulations have shown that the capacitive decay in the detector-circuit during rise-time of each pulse produces large pulse-height loss, if the detector-circuit time constant is of the order of maximum electron collection time. There, however, exists no data in support. So, we have carried out measurements on the pulse-height loss due to the capacitive decay in the detector-circuit during collection of charges for two-electrode parallel plate ionization chamber. Experimental data on the pulse-height loss match reasonably well with the theoretical predictions.

  • Measurements of Ballistic Deficits for Parallel Plate Ionization Chambers

    by S. L. Sharma, G. Anil Kumar, D. C. Biswas, R. K. Choudhury

    Ionization chambers are the important gas-filled ionization detectors for heavy ion detection and spectroscopy. As the effect of ballistic deficit is the imprecision in the measurement of the pulse-height, the measurements of ballistic deficits for the pulses from ionization chambers of different types are expected to play very important role in the heavy ion spectroscopy. We have carried out measurements on the ballistic deficits for the pulses from the two-electrode parallel plate ionization chamber as well as for the pulses from the gridded parallel plate ionization chamber by processing these pulses through a simple CR-RC shaping network with pole-zero cancellation. The height of the shaped pulse versus shaping time curves for these ionization chambers show saturation at higher shaping times. Taking saturated pulse-height as the maximum possible pulse-height, the ballistic deficits have been estimated for different shaping times and are compared with the calculations based on the numerical integration method. The experimental results are in good agreement with the theoretical predictions, showing clearly that the ballistic deficits can be made negligibly small by choosing the shaping time about four-times the maximum electron collection time.

  • A Simple Technique for Identifying Natural Alpha Emitters

    by S. L. Sharma, G. Anil Kumar, R. K. Choudhury

    It is well known that the pulse-height spectrum for the two-electrode parallel plate ionization chamber is rectangular in shape with the lower and upper bounds due to the charged particles making angles 0deg and 90deg respectively with the electric field. Clearly, by allowing charged particles of narrow range of angles only, the pulse-height spectrum can be reduced to a narrow peaking spectrum. We have made Monte Carlo simulation of the pulse-height spectra for alpha particles of energies in the range 3-9 MeV for the above ionization chamber for several electrode separations and for several narrow angular openings and optimized the electrode separation for each angular opening in order to get a linear peak position versus alpha energy plot. Each combination of the electrode separation and angular opening with the linear plot of peak position versus energy then makes the detector an important tool for identifying the alpha activities due to different natural alpha emitters found in the rock samples, sediments and environment. The emission of the charged particles from the source, charge carrier generation in the active volume, transport of the charge carriers, induction of charges on the electrodes, pulse shaping with a simple CR-RC network having pole-zero cancellation, etc. have been incorporated in these simulations. Some of these results have already been verified experimentally. Further experimental work is in progress.

  • Open Access

    Dynamical Effects in the Region of Heavy and Super-Heavy Nuclei

    by D. Fabris, A. Saxena, G. Prete, D. V. Shetty, G. Viesti, B. K. Nayak, D. C. Biswas, R. K. Choudhury, S. S. Kapoor, M. Barbui, et al.

    The transfer-induced fission channel has been studied in the collision of 340 MeV 28Si on 232Th as a function of the atomic number of the projectile-like fragments (PLF) by using a 4π detector array. The average excitation energy of the target-like fragment (TLF) is derived from the measured energy loss, whereas its angular momentum has been obtained from the angular distribution of fission fragments. The measured ratio of transfer-fission yield to PLF singles, Yf, first increase up to a net charge transfer ΔZ = 4, then shows a plateau around the values Yf = 0.4 - 0.6. This ratio can be identified as the cumulative fission probability of the populated nuclei for net charge transfer ΔZ≤6, suggesting a significant survival probability against fission of these TLF nuclei, in marked disagreement with the standard statistical model predictions. The observed survival probability implies that there is a strong hindrance to fission in the early stages of the deexcitation, such effects are important in the population of nuclei in the heavy and superheavy mass region by transfer reactions. Moreover pre- and post-scission multiplicities of neutrons and alpha particles have been simultaneously measured for the fission-like channel of the same reaction. Dynamical model calculations using HICOL code predict that 90% of the observed events are of quasi-fission type while the remaining 10% are from compound nucleus fission decay. From a comparison of PACE2 Statistical Model predictions with the measured pre-scission neutron multiplicity, the fission delay is estimated to be of 5+7−3×10−20s, which overlaps with the average duration of fission-like process from the contact to the scission point (2×10-20s) as determined from HICOL-based dynamical calculations.

  • Fission fragment angular distributions: A probe to study heavy-ion fusion dynamics

    by R. G. Thomas, R. K. Choudhury, A. K. Mohanty, A. Saxena, S. S. Kapoor

    It is shown that when fusion is initiated at relatively larger distances due to the presence of rotational couplings, the Businaro-Gallone barrier shifts towards higher mass asymmetry, thus favoring further mass equilibration towards symmetric configurations. This leads to the occurrence of preequilibrium fission events for all systems which affect the fission fragment angular distributions at subbarrier energies. The fission fragment angular distributions calculated as an admixture of compound nuclear and preequilibrium components explains quite well the energy dependence of the angular anisotropies for many systems around the actinide regions irrespective of the entrance channel mass asymmetries at energies both well below and above the Coulomb barrier. From the fits to the angular distributions, K-equilibration time is deduced to be ∼6×10−20 s for a temperature ∼1MeV.