Mitsutomo Hirota
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mitsutomo Hirota has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Tsutomu Saito
2 shared publications- Tsutomu Saito
Muroran Institute of Technology
2 shared publications - Yuichiro Yamada
Hokkaido University
2 shared publications - Yuji Nakamura
Hokkaido University
2 shared publications H. Inokuchi
1 shared publicationI. Sekimoto
1 shared publication
Latest Publications
- 1 January 2018
- Published by Japan Society for Aeronautical and Space Sciences in JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES
- Vol. 66 (1) , 1-6
Characteristics of Subsonic FTV Nozzle and Its Flight Demonstration
The characteristics of a subsonic nozzle with Fluidic Thrust Vectoring (FTV) in the pitch angle are investigated experimentally using a wind tunnel. The transient response of the FTV nozzle is also tested by mounting it on an aircraft flying at 25m/s. The FTV nozzle is designed so that a secondary jet branched from the main flow is joined at the nozzle throat and the main flow is separated from the nozzle wall surface. The deflection angle and deceleration rate of the main flow are measured with a pitot tube, and flow is visualized using a laser light sheet. The deflection angle without ventilation to the wind tunnel is up to 14deg at 100% throttle. When the FTV nozzle is operated in an air stream of 11m/s in a wind tunnel, the deflection angle is suppressed to 40%. In addition, the flight test demonstrates that the system can be used to control the flight attitude in pitch angle. During flight, there are transient delays of 1.5 seconds in pitch angle and 3 seconds in flight altitude.
- 1 January 2018
- Published by Japan Society for Aeronautical and Space Sciences in JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES
- Vol. 66 (1) , 1-6
Characteristics of Subsonic FTV Nozzle and Its Flight Demonstration
The characteristics of a subsonic nozzle with Fluidic Thrust Vectoring (FTV) in the pitch angle are investigated experimentally using a wind tunnel. The transient response of the FTV nozzle is also tested by mounting it on an aircraft flying at 25m/s. The FTV nozzle is designed so that a secondary jet branched from the main flow is joined at the nozzle throat and the main flow is separated from the nozzle wall surface. The deflection angle and deceleration rate of the main flow are measured with a pitot tube, and flow is visualized using a laser light sheet. The deflection angle without ventilation to the wind tunnel is up to 14deg at 100% throttle. When the FTV nozzle is operated in an air stream of 11m/s in a wind tunnel, the deflection angle is suppressed to 40%. In addition, the flight test demonstrates that the system can be used to control the flight attitude in pitch angle. During flight, there are transient delays of 1.5 seconds in pitch angle and 3 seconds in flight altitude.
- Open Access
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in Journal of Thermal Science and Technology
- Vol. 12 (2) , JTST0024
Soot control of laminar jet-diffusion lifted flame excited by high-frequency acoustic oscillation
A novel technology to reduce soot is developed utilizing a high-frequency standing wave of 20 kHz applied to a methane-air lifted jet flame base. The amount of soot was measured using the transmitted light attenuation method. A mixing profile of the fuel jet was visualized using acetone planar-laser-induced fluorescence in order to measure the mixing status when the ultrasonic wave was applied. The blow-off and reattached limit were increased by the standing wave. Soot was also clearly decreased under some conditions. This was detected both through a disappearance of the luminous flame and a qualitative measurement using the transmitted light attenuation method. The luminous intensity of the acetone fluorescence at the middle of the fuel jet decreased with height because the fuel jet diffused more efficiently with ultrasonic waves.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in Journal of Thermal Science and Technology
- Vol. 12 (2) , JTST0024
Open AccessSoot control of laminar jet-diffusion lifted flame excited by high-frequency acoustic oscillation
A novel technology to reduce soot is developed utilizing a high-frequency standing wave of 20 kHz applied to a methane-air lifted jet flame base. The amount of soot was measured using the transmitted light attenuation method. A mixing profile of the fuel jet was visualized using acetone planar-laser-induced fluorescence in order to measure the mixing status when the ultrasonic wave was applied. The blow-off and reattached limit were increased by the standing wave. Soot was also clearly decreased under some conditions. This was detected both through a disappearance of the luminous flame and a qualitative measurement using the transmitted light attenuation method. The luminous intensity of the acetone fluorescence at the middle of the fuel jet decreased with height because the fuel jet diffused more efficiently with ultrasonic waves.
- 17 March 2016
- Published by Springer Nature in Shock Waves
- Vol. 27 (1) , 53-61
Evaluation of fluidic thrust vectoring nozzle via thrust pitching angle and thrust pitching moment
- 17 March 2016
- Published by Springer Nature in Shock Waves
- Vol. 27 (1) , 53-61
Evaluation of fluidic thrust vectoring nozzle via thrust pitching angle and thrust pitching moment
- 14 December 2010
- Published by Springer Nature in Journal of Visualization
- Vol. 14 (1) , 75-84
Strategy to diagnose ultra-lean (ϕ < 0.6) premixed flames by acetone-OH simultaneous PLIF with one-laser and one-detector combination
- 14 December 2010
- Published by Springer Nature in Journal of Visualization
- Vol. 14 (1) , 75-84
Strategy to diagnose ultra-lean (ϕ < 0.6) premixed flames by acetone-OH simultaneous PLIF with one-laser and one-detector combination
- 1 May 1994
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 26 (04) , 365-366
Characteristic “Fish-mouth” Wound, Visible via Colonoscopy, Produced by Conventional Biopsy for Systemic Amyloidosis
- 1 May 1994
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 26 (04) , 365-366
Characteristic “Fish-mouth” Wound, Visible via Colonoscopy, Produced by Conventional Biopsy for Systemic Amyloidosis