Andrea Luparia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrea Luparia has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Giovanni Gandini
University of Torino
6 shared publications - Anna Sapino
INOC - Istituto Nazionale Oncologico Candiolo; IRCCS, Candiolo, Italy
4 shared publications G. Mariscotti
Istituto di Radiologia Diagnostica ed Interventistica, Università di Torino, AOU San Giovanni Battista di Torino, Sede Molinette, Torino, Italy
4 shared publicationsD. Lucarelli
Istituto di Radiologia Diagnostica e Interventistica, Torino, Italy
3 shared publicationsE. Regini
Istituto di Radiologia Diagnostica ed Interventistica, Università di Torino, AOU San Giovanni Battista di Torino, Sede Molinette, Torino, Italy
3 shared publicationsP. Campanino
Istituto di Radiologia Diagnostica e Interventistica, Torino, Italy
3 shared publications
Latest Publications
- 1 March 2014
- Vol. 34 (3) , 1219-25
Accuracy of mammography, digital breast tomosynthesis, ultrasound and MR imaging in preoperative assessment of breast cancer.
To define the accuracy of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to digital mammography (DM) and ultrasound (US) in the preoperative assessment of breast cancer. We performed a prospective study of 200 consecutive women with histologically-proven breast cancer using the above imaging techniques. Accuracy measurements were estimated using a lesion-by-lesion analysis for unifocal, multifocal/multicentric, bilateral and all carcinomas. We also calculated sensitivity according to breast density. DBT had higher sensitivity than DM (90.7% vs. 85.2%). Combined DM and DBT with US yielded a 97.7% sensitivity; despite high sensitivity of MRI (98.8%), the addition of MRI to combined DM with DBT and US did not significantly improve sensitivity. Overall accuracy did not significantly differ between MRI and DM with DBT and US (92.3% vs. 93.7%). Breast density affected sensitivity of DM and DBT (statistically significant difference for DM), not MRI. There is little gain in sensitivity and no gain in overall accuracy, by performing MRI for patients who have been evaluated with DM with DBT and US.
- 1 March 2014
- Vol. 34 (3) , 1219-25
Accuracy of mammography, digital breast tomosynthesis, ultrasound and MR imaging in preoperative assessment of breast cancer.
To define the accuracy of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to digital mammography (DM) and ultrasound (US) in the preoperative assessment of breast cancer. We performed a prospective study of 200 consecutive women with histologically-proven breast cancer using the above imaging techniques. Accuracy measurements were estimated using a lesion-by-lesion analysis for unifocal, multifocal/multicentric, bilateral and all carcinomas. We also calculated sensitivity according to breast density. DBT had higher sensitivity than DM (90.7% vs. 85.2%). Combined DM and DBT with US yielded a 97.7% sensitivity; despite high sensitivity of MRI (98.8%), the addition of MRI to combined DM with DBT and US did not significantly improve sensitivity. Overall accuracy did not significantly differ between MRI and DM with DBT and US (92.3% vs. 93.7%). Breast density affected sensitivity of DM and DBT (statistically significant difference for DM), not MRI. There is little gain in sensitivity and no gain in overall accuracy, by performing MRI for patients who have been evaluated with DM with DBT and US.
- 25 June 2013
- Published by Springer Nature in La radiologia medica
- Vol. 118 (7) , 1119-1136
Accuracy of tumour size assessment in the preoperative staging of breast cancer: comparison of digital mammography, tomosynthesis, ultrasound and MRI
Purpose Accurate measurement of breast tumour size is fundamental for treatment planning. We compared the accuracy of digital mammography (DM), digital breast tomosynthesis (DBT), ultrasound (US) and magnetic resonance imaging (MRI) for the preoperative evaluation of breast cancer size. Materials and methods We retrospectively reviewed 149 breast cancers in 110 patients who underwent DM, DBT, US and MRI between January 2010 and December 2011, before definitive surgery. The lesions were measured by two radiologists, without knowledge of the final histological examination, considered the gold standard. For each imaging modality, the maximum tumour size was measured to the nearest millimetre; the measurements were considered concordant if they were within ±5 mm. Pearson’s correlation coefficient was calculated for each imaging modality. Results The median pathological tumour size was 22.3 mm. MRI and DBT had a level of concordance with pathology of 70% and 66%, respectively, which was higher than that of DM (54%). DBT and MRI measurements had a better correlation with pathological tumour size (R:0.89 and R:0.92, respectively) compared to DM (R:0.83) and US (R:0.77). Conclusions DBT and MRI are superior to DM and US in the preoperative assessment of breast tumour size. DBT seems to improve the accuracy of DM, although MRI remains the most accurate imaging modality for breast cancer extension.
- 25 June 2013
- Published by Springer Nature in La radiologia medica
- Vol. 118 (7) , 1119-1136
Accuracy of tumour size assessment in the preoperative staging of breast cancer: comparison of digital mammography, tomosynthesis, ultrasound and MRI
Purpose Accurate measurement of breast tumour size is fundamental for treatment planning. We compared the accuracy of digital mammography (DM), digital breast tomosynthesis (DBT), ultrasound (US) and magnetic resonance imaging (MRI) for the preoperative evaluation of breast cancer size. Materials and methods We retrospectively reviewed 149 breast cancers in 110 patients who underwent DM, DBT, US and MRI between January 2010 and December 2011, before definitive surgery. The lesions were measured by two radiologists, without knowledge of the final histological examination, considered the gold standard. For each imaging modality, the maximum tumour size was measured to the nearest millimetre; the measurements were considered concordant if they were within ±5 mm. Pearson’s correlation coefficient was calculated for each imaging modality. Results The median pathological tumour size was 22.3 mm. MRI and DBT had a level of concordance with pathology of 70% and 66%, respectively, which was higher than that of DM (54%). DBT and MRI measurements had a better correlation with pathological tumour size (R:0.89 and R:0.92, respectively) compared to DM (R:0.83) and US (R:0.77). Conclusions DBT and MRI are superior to DM and US in the preoperative assessment of breast tumour size. DBT seems to improve the accuracy of DM, although MRI remains the most accurate imaging modality for breast cancer extension.
- 8 August 2012
- Published by Springer Nature in La radiologia medica
- Vol. 118 (3) , 401-414
Breast cancer surveillance in patients treated by radiotherapy for Hodgkin’s lymphoma
Purpose The authors evaluated the relative risk of developing radiation-induced breast cancer (BC) in women treated with radiotherapy for Hodgkin’s disease (HD) and analysed the imaging features of these breast neoplasms. Materials and methods We retrospectively studied 54 women who had all undergone radiotherapy between 1980 and 2010 (median age, 36.6 years). Women aged ≤30 years were screened with clinical breast examination, ultrasound (US) and, if necessary, mammography; women >30 years had clinical breast examination, US and mammography. Three women underwent magnetic resonance (MR) imaging as well. Results Mammography detected seven invasive breast cancers in 6/54 women (11.1%). Median age at diagnosis was 26.1 years for HD and 42.4 for breast cancer. Breast cancer was diagnosed following a median latent period from radiotherapy of 15.1 years. Mean radiation dose was 37.6 Gy in women who developed breast cancer and 31.3 Gy in the other women. Conclusions In our study, women who were exposed to radiation for HD had a 6.2-fold higher risk of developing breast cancer than the general population. In consideration of the young age and high breast density, women aged ≤30 years should be monitored by US and MR imaging; women aged >30 years should be monitored by US, mammography and, when necessary, MR imaging.
- 8 August 2012
- Published by Springer Nature in La radiologia medica
- Vol. 118 (3) , 401-414
Breast cancer surveillance in patients treated by radiotherapy for Hodgkin’s lymphoma
Purpose The authors evaluated the relative risk of developing radiation-induced breast cancer (BC) in women treated with radiotherapy for Hodgkin’s disease (HD) and analysed the imaging features of these breast neoplasms. Materials and methods We retrospectively studied 54 women who had all undergone radiotherapy between 1980 and 2010 (median age, 36.6 years). Women aged ≤30 years were screened with clinical breast examination, ultrasound (US) and, if necessary, mammography; women >30 years had clinical breast examination, US and mammography. Three women underwent magnetic resonance (MR) imaging as well. Results Mammography detected seven invasive breast cancers in 6/54 women (11.1%). Median age at diagnosis was 26.1 years for HD and 42.4 for breast cancer. Breast cancer was diagnosed following a median latent period from radiotherapy of 15.1 years. Mean radiation dose was 37.6 Gy in women who developed breast cancer and 31.3 Gy in the other women. Conclusions In our study, women who were exposed to radiation for HD had a 6.2-fold higher risk of developing breast cancer than the general population. In consideration of the young age and high breast density, women aged ≤30 years should be monitored by US and MR imaging; women aged >30 years should be monitored by US, mammography and, when necessary, MR imaging.
- 28 July 2011
- Published by Springer Nature in La radiologia medica
- Vol. 116 (6) , 982-984
B3 core biopsies should be assumed as positive findings for accuracy purposes
- 28 July 2011
- Published by Springer Nature in La radiologia medica
- Vol. 116 (6) , 982-984
B3 core biopsies should be assumed as positive findings for accuracy purposes
- 12 January 2011
- Published by Springer Nature in La radiologia medica
- Vol. 116 (3) , 477-488
Biopsia percutanea vacuum assistita nelle lesioni mammarie non palpabili: analisi dell’efficacia e dei costi su 602 casi in cinque anni di esperienza
- 12 January 2011
- Published by Springer Nature in La radiologia medica
- Vol. 116 (3) , 477-488
Biopsia percutanea vacuum assistita nelle lesioni mammarie non palpabili: analisi dell’efficacia e dei costi su 602 casi in cinque anni di esperienza
- 30 September 2009
- Published by Springer Nature in La radiologia medica
- Vol. 115 (2) , 225-237
Role of axillary ultrasound in the preoperative diagnosis of lymph node metastases in patients affected by breast carcinoma
This study was conducted to evaluate the diagnostic accuracy of axillary ultrasound (US) alone or in combination with fine-needle-aspiration cytology (FNAC) in patients with breast carcinoma, in comparison with the final histological examination (sentinel node biopsy and/or axillary dissection). Between January 2005 and June 2008, we evaluated 427 breast cancer patients with axillary US. The findings were classified according to the following criteria: hilum and cortex morphology, ratio between longitudinal and transverse diameter and ratio between hilar and longitudinal diameter of the lymph node. Patients with breast lesions ≤3 cm (n=147) underwent FNAC of the most suspicious lymph node. Overall concordance between axillary US and final histological examination was 85%, sensitivity was 72.3% and specificity was 93.4%. Concordance between FNAC and final histological examination was 93%, sensitivity was 88.1% and specificity was 100%. In 48.3% of patients, the combination of axillary US and FNAC guided treatment decisions towards immediate axillary dissection, thus sparing the patients sentinel node biopsy, with a significant reduction of costs and hospitalization time. Scopo del nostro lavoro è stato valutare, in pazienti affette da carcinoma mammario, l’accuratezza diagnostica dell’ecografia (US) del cavo ascellare da sola oppure associata ad agoaspirato con ago sottile (FNAC) assumendo come parametro di confronto l’esame istologico definitivo (biopsia del linfonodo sentinella e/o dissezione ascellare). Tra gennaio 2005 e giugno 2008 in 427 pazienti affette da neoplasia mammaria è stato eseguito lo studio ecografico del cavo ascellare. Per la classificazione dei reperti ecografici sono stati valutati: la morfologia dell’ilo e della corticale, il rapporto tra diametro longitudinale e trasversale e il rapporto tra diametro della regione ilare e longitudinale del linfonodo. In 147 pazienti, con neoplasia mammaria≤3 cm, è stata eseguita l’US-FNAC del linfonodo più sospetto. Si è evidenziata una concordanza complessiva tra US del cavo ascellare e istologico definitivo dell’85%, una sensibilità del 72,3% ed una specificità del 93,4%. La concordanza dell’US-FNAC con l’istologico definitivo è risultata del 93%, la sensibilità dell’88,1% e la specificità del 100%. L’ecografia del cavo ascellare associata alla FNAC nel 48,3% dei casi ha permesso di evitare la biopsia del linfonodo sentinella, orientando il trattamento chirurgico verso una dissezione ascellare immediata, con sensibile riduzione dei costi e del tempo di ospedalizzazione.
- 30 September 2009
- Published by Springer Nature in La radiologia medica
- Vol. 115 (2) , 225-237
Role of axillary ultrasound in the preoperative diagnosis of lymph node metastases in patients affected by breast carcinoma
This study was conducted to evaluate the diagnostic accuracy of axillary ultrasound (US) alone or in combination with fine-needle-aspiration cytology (FNAC) in patients with breast carcinoma, in comparison with the final histological examination (sentinel node biopsy and/or axillary dissection). Between January 2005 and June 2008, we evaluated 427 breast cancer patients with axillary US. The findings were classified according to the following criteria: hilum and cortex morphology, ratio between longitudinal and transverse diameter and ratio between hilar and longitudinal diameter of the lymph node. Patients with breast lesions ≤3 cm (n=147) underwent FNAC of the most suspicious lymph node. Overall concordance between axillary US and final histological examination was 85%, sensitivity was 72.3% and specificity was 93.4%. Concordance between FNAC and final histological examination was 93%, sensitivity was 88.1% and specificity was 100%. In 48.3% of patients, the combination of axillary US and FNAC guided treatment decisions towards immediate axillary dissection, thus sparing the patients sentinel node biopsy, with a significant reduction of costs and hospitalization time. Scopo del nostro lavoro è stato valutare, in pazienti affette da carcinoma mammario, l’accuratezza diagnostica dell’ecografia (US) del cavo ascellare da sola oppure associata ad agoaspirato con ago sottile (FNAC) assumendo come parametro di confronto l’esame istologico definitivo (biopsia del linfonodo sentinella e/o dissezione ascellare). Tra gennaio 2005 e giugno 2008 in 427 pazienti affette da neoplasia mammaria è stato eseguito lo studio ecografico del cavo ascellare. Per la classificazione dei reperti ecografici sono stati valutati: la morfologia dell’ilo e della corticale, il rapporto tra diametro longitudinale e trasversale e il rapporto tra diametro della regione ilare e longitudinale del linfonodo. In 147 pazienti, con neoplasia mammaria≤3 cm, è stata eseguita l’US-FNAC del linfonodo più sospetto. Si è evidenziata una concordanza complessiva tra US del cavo ascellare e istologico definitivo dell’85%, una sensibilità del 72,3% ed una specificità del 93,4%. La concordanza dell’US-FNAC con l’istologico definitivo è risultata del 93%, la sensibilità dell’88,1% e la specificità del 100%. L’ecografia del cavo ascellare associata alla FNAC nel 48,3% dei casi ha permesso di evitare la biopsia del linfonodo sentinella, orientando il trattamento chirurgico verso una dissezione ascellare immediata, con sensibile riduzione dei costi e del tempo di ospedalizzazione.