Lizhu Hou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lizhu Hou has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Bill Hu
Yellow River Research Institute, North China University of Water Resources and Electric Power, Zhengzhou 450046, China
2 shared publications - Chuanping Feng
School of Water Resources and Environment, MOE Key Laboratory of Groundwater Circulation and Environmental Evolution, China University of Geosciences (Beijing), Beijing 100083, PR China
2 shared publications Li Wan
MOE Key Laboratory of Groundwater Circulation and Environmental Evolution China University of Geosciences (Beijing) Beijing China
2 shared publicationsXue Xu
School of Water Resources and Environment, China University of Geosciences (Beijing), No. 29 Xueyuan Road, Haidian District, Beijing, 100083, China
2 shared publicationsFang Liu
School of Water Resources and Environmental Science, China University of Geosciences (Beijing), No. 29 Xueyuan Road, Haidian District, Beijing 100083, China
1 shared publicationHaiyuan Lu
School of Water Resources and Environment, China University of Geosciences (Beijing), No. 29, Xueyuan Road, Haidian District, Beijing 100083, China
1 shared publication
Latest Publications
- Open Access
- 20 September 2018
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 123 (18) , 10183-10195
Potential Impacts of Climate Variation on Potato Field Evapotranspiration: Field Experiment and Numerical Simulation of Potato Water Use in an Arid Site
Climate change would significantly affect crop evapotranspiration processes. Many studies have been conducted for various crops. However, there is a lack of sufficient observational evidence on how climate change would influence potato evapotranspiration. In this paper, an experimental potato field in Maowusu Desert, northwest of China, was used to investigate the effect of climate change on potato evapotranspiration. Temporal variations in reference evapotranspiration (ET0) were comprehensively investigated during 1954–2013, which shows that annual temperature and ET0 had significant increasing trends in the past 60 years. Meanwhile, an experimental crop of potato was grown in Maowusu Desert to investigate water‐soil‐air‐plant‐human nexus in 2016, and a HYDRUS‐1D model for the unsaturated flow in a potato field was calibrated and validated with measured soil water tensions and soil water contents at various depths during the potato growing periods from 8 to 16 August 2016 and from 6 September to 3 October 2016, respectively. The model computed the actual potato evapotranspiration (ETa) as 183 mm during the whole growing period from 5 June to 3 October 2016. The groundwater contribution to potato water use was calculated to be 320 mm during the growing season in 2016. As the atmospheric temperature increases, the reference crop evapotranspiration increases, the actual potato evapotranspiration increases too. The actual potato evapotranspiration increase with temperature increase will lead to a bigger water resource pressure in this area. The study results provide the basis for managing crop irrigation in the region in the future.
- 20 September 2018
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 123 (18) , 10183-10195
Open AccessPotential Impacts of Climate Variation on Potato Field Evapotranspiration: Field Experiment and Numerical Simulation of Potato Water Use in an Arid Site
Climate change would significantly affect crop evapotranspiration processes. Many studies have been conducted for various crops. However, there is a lack of sufficient observational evidence on how climate change would influence potato evapotranspiration. In this paper, an experimental potato field in Maowusu Desert, northwest of China, was used to investigate the effect of climate change on potato evapotranspiration. Temporal variations in reference evapotranspiration (ET0) were comprehensively investigated during 1954–2013, which shows that annual temperature and ET0 had significant increasing trends in the past 60 years. Meanwhile, an experimental crop of potato was grown in Maowusu Desert to investigate water‐soil‐air‐plant‐human nexus in 2016, and a HYDRUS‐1D model for the unsaturated flow in a potato field was calibrated and validated with measured soil water tensions and soil water contents at various depths during the potato growing periods from 8 to 16 August 2016 and from 6 September to 3 October 2016, respectively. The model computed the actual potato evapotranspiration (ETa) as 183 mm during the whole growing period from 5 June to 3 October 2016. The groundwater contribution to potato water use was calculated to be 320 mm during the growing season in 2016. As the atmospheric temperature increases, the reference crop evapotranspiration increases, the actual potato evapotranspiration increases too. The actual potato evapotranspiration increase with temperature increase will lead to a bigger water resource pressure in this area. The study results provide the basis for managing crop irrigation in the region in the future.
- 1 April 2018
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 25 (10) , 9615-9625
Effect of intermittent operation model on the function of soil infiltration system
To enhance denitrification in a process of solute infiltration through a soil, a two-section mixed-medium soil infiltration system (TMSIS) for urban non-point pollution was developed. The artificial aerobic respiration and nitrification took place in the upper aerobic section (AES), while grass powders and sawdust were mixed in the bottom anaerobic section (ANS) to supply organic carbon source for denitrification bacteria, and the reduction was increased by iron addition in the ANS. Measured resident concentrations from the bottom of each ANS column were assumed to represent mean values averaged over the column cross-sectional area. The TMSIS with hydraulic loading rates (HLR) of 0.32, 0.24, and 0.16 m(3) m(-2) day(-1) and with wetting-drying ratio (R-WD) of 1.0 showed remarkable removal efficiencies for chemical oxygen demand (COD), NH4+-N, and TP, respectively. The hydraulic loading rate of 0.32 m(3) m(-2) day(-1) was selected as the optimal HLR due to the high contaminated runoff treatment efficiency. When R-WD was 1.0, 0.5, or 0.2 with hydraulic loading rate of 0.32 m(3) m(-2) day(-1), the TMSIS could treat synthetic urban runoff contaminants very well. The corresponding effluent water met the China's national quality standard for class V surface water. The wetting-drying ratio of 0.5 with hydraulic loading of 0.32 m(3) m(-2) day(-1) was selected as the optimal operation conditions for the TMSIS. Aerobic respiration and nitrification mainly took place in the upper AES, in which most of the COD and the NH4+-N were removed. Mixed sawdust and grass powders used as a carbon source and heterotrophic denitrification were put at the bottom of the ANS. The developed TMSIS has the potential to be applied for urban non-point pollution removal.
- 1 April 2018
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 25 (10) , 9615-9625
Effect of intermittent operation model on the function of soil infiltration system
To enhance denitrification in a process of solute infiltration through a soil, a two-section mixed-medium soil infiltration system (TMSIS) for urban non-point pollution was developed. The artificial aerobic respiration and nitrification took place in the upper aerobic section (AES), while grass powders and sawdust were mixed in the bottom anaerobic section (ANS) to supply organic carbon source for denitrification bacteria, and the reduction was increased by iron addition in the ANS. Measured resident concentrations from the bottom of each ANS column were assumed to represent mean values averaged over the column cross-sectional area. The TMSIS with hydraulic loading rates (HLR) of 0.32, 0.24, and 0.16 m(3) m(-2) day(-1) and with wetting-drying ratio (R-WD) of 1.0 showed remarkable removal efficiencies for chemical oxygen demand (COD), NH4+-N, and TP, respectively. The hydraulic loading rate of 0.32 m(3) m(-2) day(-1) was selected as the optimal HLR due to the high contaminated runoff treatment efficiency. When R-WD was 1.0, 0.5, or 0.2 with hydraulic loading rate of 0.32 m(3) m(-2) day(-1), the TMSIS could treat synthetic urban runoff contaminants very well. The corresponding effluent water met the China's national quality standard for class V surface water. The wetting-drying ratio of 0.5 with hydraulic loading of 0.32 m(3) m(-2) day(-1) was selected as the optimal operation conditions for the TMSIS. Aerobic respiration and nitrification mainly took place in the upper AES, in which most of the COD and the NH4+-N were removed. Mixed sawdust and grass powders used as a carbon source and heterotrophic denitrification were put at the bottom of the ANS. The developed TMSIS has the potential to be applied for urban non-point pollution removal.
- 15 August 2016
- Published by Taylor & Francis in Hydrological Sciences Journal
- Vol. 62 (1) , 1-11
Simulation of maize (Zea maysL.) water use with the HYDRUS-1D model in the semi-arid Hailiutu River catchment, Northwest China
Groundwater provides an important source of water for maize cultivation where the water table is shallow in the semi-arid Hailiutu River catchment of the Maowusu Desert on the Erdos Plateau in Northwest China. A HYDRUS-1D model of the unsaturated flow beneath a maize (Zea mays L.) field was calibrated and validated with measured soil water contents at various depths during the maize growing period from 30 April to 1 October 2011, and from 23 May to 27 September 2012, respectively. The model computed the actual maize evapotranspiration (ETa) as 580 mm during the whole growing period from 30 April to 1 October 2011. The groundwater contribution to ETa was calculated to be 220 mm, accounting for 38% of maize water use during the growing season in 2011. When the groundwater level drops below a depth of 157 cm, maize can no longer use groundwater for transpiration. The irrigation water requirement increases with the increase of groundwater table depth. These results are very important for managing crop irrigation in the area.
- 15 August 2016
- Published by Taylor & Francis in Hydrological Sciences Journal
- Vol. 62 (1) , 1-11
Simulation of maize (Zea maysL.) water use with the HYDRUS-1D model in the semi-arid Hailiutu River catchment, Northwest China
Groundwater provides an important source of water for maize cultivation where the water table is shallow in the semi-arid Hailiutu River catchment of the Maowusu Desert on the Erdos Plateau in Northwest China. A HYDRUS-1D model of the unsaturated flow beneath a maize (Zea mays L.) field was calibrated and validated with measured soil water contents at various depths during the maize growing period from 30 April to 1 October 2011, and from 23 May to 27 September 2012, respectively. The model computed the actual maize evapotranspiration (ETa) as 580 mm during the whole growing period from 30 April to 1 October 2011. The groundwater contribution to ETa was calculated to be 220 mm, accounting for 38% of maize water use during the growing season in 2011. When the groundwater level drops below a depth of 157 cm, maize can no longer use groundwater for transpiration. The irrigation water requirement increases with the increase of groundwater table depth. These results are very important for managing crop irrigation in the area.
- 28 May 2015
- Published by IWA Publishing in Hydrology Research
- Vol. 47 (1) , 128-136
A two-stage soil infiltration system incorporated with heterotrophic denitrification (TSISHD) for urban runoff treatment
To enhance denitrification performance of soil infiltration, a soil infiltration system incorporated with heterotrophic denitrification (TSISHD) for urban runoff treatment was developed. Sawdust and grass powders were added in the anaerobic stage (ANS) to provide organic carbon sources for the denitrification process, and the reduction environment was improved by iron addition in the ANS. Aerobic respiration and nitrification primarily occurred in the upper aerobic stage (AES), which removed 86.68% of the chemical oxygen demand (COD) and 91.80% of the NH4+-N. Moreover, heterotrophic denitrification occurred in the bottom ANS when added sawdust and grass powders were used as a carbon source. Overall, the TSISHD showed remarkable removal efficiencies of 88.29%, 82.50%, 92.05%, and 78.10% for COD, NO3--N, NH4+-N, and total phosphorus, respectively, and the corresponding effluent concentrations met the national quality standard of China for class V surface water. The removal efficiencies were significantly higher than those of the previous soil infiltration systems without inoculated microbes. The developed system has the potential to treat urban runoff.
- 28 May 2015
- Published by IWA Publishing in Hydrology Research
- Vol. 47 (1) , 128-136
A two-stage soil infiltration system incorporated with heterotrophic denitrification (TSISHD) for urban runoff treatment
To enhance denitrification performance of soil infiltration, a soil infiltration system incorporated with heterotrophic denitrification (TSISHD) for urban runoff treatment was developed. Sawdust and grass powders were added in the anaerobic stage (ANS) to provide organic carbon sources for the denitrification process, and the reduction environment was improved by iron addition in the ANS. Aerobic respiration and nitrification primarily occurred in the upper aerobic stage (AES), which removed 86.68% of the chemical oxygen demand (COD) and 91.80% of the NH4+-N. Moreover, heterotrophic denitrification occurred in the bottom ANS when added sawdust and grass powders were used as a carbon source. Overall, the TSISHD showed remarkable removal efficiencies of 88.29%, 82.50%, 92.05%, and 78.10% for COD, NO3--N, NH4+-N, and total phosphorus, respectively, and the corresponding effluent concentrations met the national quality standard of China for class V surface water. The removal efficiencies were significantly higher than those of the previous soil infiltration systems without inoculated microbes. The developed system has the potential to treat urban runoff.
- 9 April 2015
- Published by IWA Publishing in Water Supply
- Vol. 15 (5) , 924-932
Soil water movement under a drip irrigation double-point source
Particularly in dry regions, the scarcity of high-quality fresh water has heightened the importance of urban runoff water re-use, leading as well to the improvement of water use efficiency through the surface drip irrigation method. Given the limited research on wetting front migration under a surface drip irrigation emitter, soil water movement under a double-point-source irrigation emitter was investigated. An experimental soil bin was designed and filled with silt loam soil, and time domain reflectometry and tensiometers were used to measure soil moisture contents and soil water potential, respectively. The results show that under the conditions of 6 hours of irrigation with two drippers each delivering 1.05 L hr−1 and spaced at 45 cm, the soil moisture content of the 0–30 cm layer increased rapidly and reached 0.29 cm3 cm−3, and was greater than that in the 30–60 cm layer as irrigation proceeded. After 6 hours the irrigation was stopped, such that in the redistribution phase, soil moisture of the top layer gradually decreased, while that of the sublayer gradually increased. The results indicate that 6 hours of irrigation under given emitter flow conditions produced adequate soil moisture down to 30 cm for most shallow-rooted crops.
- 9 April 2015
- Published by IWA Publishing in Water Supply
- Vol. 15 (5) , 924-932
Soil water movement under a drip irrigation double-point source
Particularly in dry regions, the scarcity of high-quality fresh water has heightened the importance of urban runoff water re-use, leading as well to the improvement of water use efficiency through the surface drip irrigation method. Given the limited research on wetting front migration under a surface drip irrigation emitter, soil water movement under a double-point-source irrigation emitter was investigated. An experimental soil bin was designed and filled with silt loam soil, and time domain reflectometry and tensiometers were used to measure soil moisture contents and soil water potential, respectively. The results show that under the conditions of 6 hours of irrigation with two drippers each delivering 1.05 L hr−1 and spaced at 45 cm, the soil moisture content of the 0–30 cm layer increased rapidly and reached 0.29 cm3 cm−3, and was greater than that in the 30–60 cm layer as irrigation proceeded. After 6 hours the irrigation was stopped, such that in the redistribution phase, soil moisture of the top layer gradually decreased, while that of the sublayer gradually increased. The results indicate that 6 hours of irrigation under given emitter flow conditions produced adequate soil moisture down to 30 cm for most shallow-rooted crops.
- 5 November 2013
- Published by IWA Publishing in Water Science & Technology
- Vol. 69 (2) , 398-406
Removal of chemical oxygen demand and dissolved nutrients by a sunken lawn infiltration system during intermittent storm events
Urban surface water runoff typically contains high but varying amounts of organic matter and nutrients that require removal before reuse. Infiltration systems such as sunken lawns can improve water quality. However, there is currently insufficient information describing the treatment efficiency of lawn-based infiltration systems. In this study, novel sunken lawn infiltration systems (SLISs) were designed and their pollutant removal effectiveness was assessed. The results revealed that SLISs with Poa pratensis and Lolium perenne effectively removed most chemical oxygen demand (CODCr) and dissolved nutrients. Average CODCr, total nitrogen (TN), ammonium–nitrogen (NH4+-N) and total phosphorus (TP) concentrations were reduced by 78.93, 66.64, 71.86 and 75.83%, respectively, and the corresponding effluent concentrations met the standard for urban miscellaneous water consumption in China. The NH4+-N in the synthetic runoff was shown to be removed by adsorption during the stormwater dosing and nitrification during subsequent dry days, as well as through uptake by plants. Phosphorus was mainly removed by adsorption and chemical precipitation. The NH4+-N and phosphorus Langmuir isotherm model fitted the clay loam soil adsorption process better than the Freundlich model. Overall, these results indicate that an SLIS provides an alternative means of removing runoff pollutants owing to its efficiency, easy operation and maintenance.
- 5 November 2013
- Published by IWA Publishing in Water Science & Technology
- Vol. 69 (2) , 398-406
Removal of chemical oxygen demand and dissolved nutrients by a sunken lawn infiltration system during intermittent storm events
Urban surface water runoff typically contains high but varying amounts of organic matter and nutrients that require removal before reuse. Infiltration systems such as sunken lawns can improve water quality. However, there is currently insufficient information describing the treatment efficiency of lawn-based infiltration systems. In this study, novel sunken lawn infiltration systems (SLISs) were designed and their pollutant removal effectiveness was assessed. The results revealed that SLISs with Poa pratensis and Lolium perenne effectively removed most chemical oxygen demand (CODCr) and dissolved nutrients. Average CODCr, total nitrogen (TN), ammonium–nitrogen (NH4+-N) and total phosphorus (TP) concentrations were reduced by 78.93, 66.64, 71.86 and 75.83%, respectively, and the corresponding effluent concentrations met the standard for urban miscellaneous water consumption in China. The NH4+-N in the synthetic runoff was shown to be removed by adsorption during the stormwater dosing and nitrification during subsequent dry days, as well as through uptake by plants. Phosphorus was mainly removed by adsorption and chemical precipitation. The NH4+-N and phosphorus Langmuir isotherm model fitted the clay loam soil adsorption process better than the Freundlich model. Overall, these results indicate that an SLIS provides an alternative means of removing runoff pollutants owing to its efficiency, easy operation and maintenance.
- 17 August 2013
- Published by IWA Publishing in Hydrology Research
- Vol. 45 (2) , 282-291
Comparing urban runoff quality of a felt roof and an asphalt road in Beijing
Water pollution and water shortage are two of the most important environmental problems in Beijing, China. Water quality of rainfall from July to August 2011 and runoff from a felt roof and an asphalt road were analyzed chemically and further investigated because these are potential sources for augmenting city supplies. Results indicate that chemical oxygen demand (CODCr), total phosphorus (TP), total nitrogen (TN), and ammonia nitrogen (NH4+-N) concentrations of initial runoff from roofs and roads all exceeded the Class V surface water quality standard developed by the Ministry of Environmental Protection of the People's Republic of China (MEP). CODCr concentration from road surfaces was more than 313.55 mg/L at the initial runoff stage, decreasing asymptotically to lower levels with increased rainfall duration. There is strong correlation between CODCr, TP, TN concentrations and that of total suspended solids in road runoff. Runoff from roofs, after treatment by grid filter, flocculation and sedimentation, can be used as city municipal and domestic water except during the initial runoff stage. However, runoff from road surfaces cannot be directly reused. For city planning, this conclusion may benefit the promotion of rainwater as a renewable water supply, and avoid flooding and water scarcity.
- 17 August 2013
- Published by IWA Publishing in Hydrology Research
- Vol. 45 (2) , 282-291
Comparing urban runoff quality of a felt roof and an asphalt road in Beijing
Water pollution and water shortage are two of the most important environmental problems in Beijing, China. Water quality of rainfall from July to August 2011 and runoff from a felt roof and an asphalt road were analyzed chemically and further investigated because these are potential sources for augmenting city supplies. Results indicate that chemical oxygen demand (CODCr), total phosphorus (TP), total nitrogen (TN), and ammonia nitrogen (NH4+-N) concentrations of initial runoff from roofs and roads all exceeded the Class V surface water quality standard developed by the Ministry of Environmental Protection of the People's Republic of China (MEP). CODCr concentration from road surfaces was more than 313.55 mg/L at the initial runoff stage, decreasing asymptotically to lower levels with increased rainfall duration. There is strong correlation between CODCr, TP, TN concentrations and that of total suspended solids in road runoff. Runoff from roofs, after treatment by grid filter, flocculation and sedimentation, can be used as city municipal and domestic water except during the initial runoff stage. However, runoff from road surfaces cannot be directly reused. For city planning, this conclusion may benefit the promotion of rainwater as a renewable water supply, and avoid flooding and water scarcity.
- 1 April 2013
- Published by IWA Publishing in Water Science & Technology
- Vol. 67 (8) , 1851-1858
Efficiencies of multilayer infiltration systems for the removal of urban runoff pollutants
Current rates of urban development will result in water runoff becoming a major complication of urban water pollution. To address the worsening situation regarding water resource shortage and pollution, novel multilayer infiltration systems were designed and their effectiveness for removing pollutants in urban runoff tested experimentally. The multilayer infiltration systems effectively removed most pollutants, including organic matter (chemical oxygen demand (CODCr)), total nitrogen (TN), ammonia-nitrogen (NH4(+)-N) and total phosphorus (TP). CODCr, TN, NH4(+)-N, and TP were reduced by 68.67, 23.98, 82.66 and 92.11%, respectively. The main mechanism for nitrogen removal was biological nitrogen removal through nitrification and denitrification. Phosphorus in the urban runoff was removed mainly by fixation processes in the soil, such as adsorption and chemical precipitation. The results indicate that the proposed novel system has potential for removal of pollutants from urban runoff and subsequent reuse of the treated water.
- 1 April 2013
- Published by IWA Publishing in Water Science & Technology
- Vol. 67 (8) , 1851-1858
Efficiencies of multilayer infiltration systems for the removal of urban runoff pollutants
Current rates of urban development will result in water runoff becoming a major complication of urban water pollution. To address the worsening situation regarding water resource shortage and pollution, novel multilayer infiltration systems were designed and their effectiveness for removing pollutants in urban runoff tested experimentally. The multilayer infiltration systems effectively removed most pollutants, including organic matter (chemical oxygen demand (CODCr)), total nitrogen (TN), ammonia-nitrogen (NH4(+)-N) and total phosphorus (TP). CODCr, TN, NH4(+)-N, and TP were reduced by 68.67, 23.98, 82.66 and 92.11%, respectively. The main mechanism for nitrogen removal was biological nitrogen removal through nitrification and denitrification. Phosphorus in the urban runoff was removed mainly by fixation processes in the soil, such as adsorption and chemical precipitation. The results indicate that the proposed novel system has potential for removal of pollutants from urban runoff and subsequent reuse of the treated water.