Pierre Le Béguec
Pierre Le Béguec has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- François Bonnomet
Hôpital de Hautepierre, CHU Strasbourg, avenue Molière, 67098, Strasbourg Cedex, France
2 shared publications - François Canovas
Hôpital Lapeyronie, CHU Montpellier, 371 Avenue du Doyen Gaston Giraud, 34295, Montpellier Cedex, France
2 shared publications - Olivier Roche
Centre Chirurgical Emile Gallé, 49 rue Hermite, 54000, Nancy, France
2 shared publications H. P. Sieber
Centre hospitalier de Bienne
1 shared publication- Henri Migaud
Orthopaedics & Traumatology: Surgery & Research, 56 rue Boissonade, 75014, Paris, France
1 shared publication Julien Girard
Hôpital Roger Salengro, CHU Lille, 2 Avenue Oscar Lambret, 59037, Lille Cedex, France
1 shared publication
Latest Publications
- 7 October 2017
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (5) , 1007-1013
Global radiological score for femoral cementless revision stem
The purpose of this study was to evaluate the outcomes of total hip arthroplasty (THA) revision with cementless stems using a numeric global radiological score (GRxS) that summarizes two previously validated scores: secondary bone stock (SBS) and osseointegration–secondary stability (O-SS).
- 7 October 2017
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (5) , 1007-1013
Global radiological score for femoral cementless revision stem
The purpose of this study was to evaluate the outcomes of total hip arthroplasty (THA) revision with cementless stems using a numeric global radiological score (GRxS) that summarizes two previously validated scores: secondary bone stock (SBS) and osseointegration–secondary stability (O-SS).
- 17 November 2015
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (5) , 907-912
Assessment of fixation in cementless femoral revision of total hip arthroplasty: comparison of the Engh score versus radiolucent line measurement
To assess osseointegration and stability of a primary cementless femoral stem, many scoring systems have been developed, but none of them have taken into account only the radiolucent line. The purposes of this study were (1) to compare the results between the Engh score to assess osseointegration and stability of the cementless stem with results of a score called the O-SS score (osseointegration-secondary stability), which takes into account the radiolucent line, (2) to verify the relationship between these two scores and the functional results, and (3) to verify if there is a relationship between the O-SS score and secondary subsidence or a pedestal. A clinical and radiological evaluation was performed in a group of 100 hip prosthesis revisions comparing the results obtained by Engh score and O-SS score for which reproducibility was analysed. Inter-observer reproducibility was estimated to be average at 0.5 and intra-observer reproducibility good at 0.7. The correlation with the Engh score was good at r = 0.59 (p < 0.0001). For the 80 cases assessed O-SS score as very good/good, Harris hip score was at 83.7 versus 78.25 for the 20 cases assessed as average/poor (p = 0.07). For the 73 cases with assessed Engh score as very good/good, this score was at 82.8 versus 82.14 for the 27 cases assessed as average/poor. No correlation between the O-SS score and secondary subsidence (p = 0.2) or pedestal (p = 0.2) was noticed. The evaluation of the clear radiolucent line alone, extent and location, is a sufficient condition to assess osseointegration and secondary stability of a cementless femoral stem.
- 17 November 2015
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (5) , 907-912
Assessment of fixation in cementless femoral revision of total hip arthroplasty: comparison of the Engh score versus radiolucent line measurement
To assess osseointegration and stability of a primary cementless femoral stem, many scoring systems have been developed, but none of them have taken into account only the radiolucent line. The purposes of this study were (1) to compare the results between the Engh score to assess osseointegration and stability of the cementless stem with results of a score called the O-SS score (osseointegration-secondary stability), which takes into account the radiolucent line, (2) to verify the relationship between these two scores and the functional results, and (3) to verify if there is a relationship between the O-SS score and secondary subsidence or a pedestal. A clinical and radiological evaluation was performed in a group of 100 hip prosthesis revisions comparing the results obtained by Engh score and O-SS score for which reproducibility was analysed. Inter-observer reproducibility was estimated to be average at 0.5 and intra-observer reproducibility good at 0.7. The correlation with the Engh score was good at r = 0.59 (p < 0.0001). For the 80 cases assessed O-SS score as very good/good, Harris hip score was at 83.7 versus 78.25 for the 20 cases assessed as average/poor (p = 0.07). For the 73 cases with assessed Engh score as very good/good, this score was at 82.8 versus 82.14 for the 27 cases assessed as average/poor. No correlation between the O-SS score and secondary subsidence (p = 0.2) or pedestal (p = 0.2) was noticed. The evaluation of the clear radiolucent line alone, extent and location, is a sufficient condition to assess osseointegration and secondary stability of a cementless femoral stem.
- 1 June 2008
- Published by Springer Nature in Interactive Surgery
- Vol. 3 (2) , 89-96
The press-fit concept: an effective but demanding concept!
- 1 June 2008
- Published by Springer Nature in Interactive Surgery
- Vol. 3 (2) , 89-96
The press-fit concept: an effective but demanding concept!