Nicola J. Cairns
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Nicola J. Cairns has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Clayton J. Adam
Queensland University of Technology
2 shared publicationsJames Smeathers
Queensland University of Technology
2 shared publications- Mark John Pearcy
Paediatric Spine Research Group, Queensland University of Technology and Mater Health Services Brisbane Ltd, Queensland, Australia
2 shared publications - Angus Kennedy McFadyen
Akm-stats, Glasgow, Scotland, UK
1 shared publication Jonathan Corney
Department of Design, Manufacture and Engineering Management, University of Strathclyde, Glasgow, UK
1 shared publicationKevin Murray
National Centre for Prosthetics and Orthotics, Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
1 shared publication
Latest Publications
- Open Access
- 1 December 2014
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 38 (6) , 467-473
Satisfaction with cosmesis and priorities for cosmesis design reported by lower limb amputees in the United Kingdom
Amputee satisfaction with cosmesis and the importance they place on cosmesis design have not been published in the literature. To investigate the current satisfaction levels of amputees in the United Kingdom with their cosmesis and the importance placed on attributes of cosmesis design to inform future cosmesis redesign. Cross-sectional questionnaire study. Questionnaires were administered to lower limb amputees in the United Kingdom. Satisfaction scores and the overall importance ranking of cosmesis features were calculated. Statistically significant relationships between two demographic, satisfaction or importance variables were tested using Fisher’s exact tests (one-tailed) at a significance level p = 0.05. Between 49% and 64% of respondents reported neutral or dissatisfied opinions with the cosmesis features (greater than 50% for five of the nine features). The three most important features identified were shape matching the cosmesis to the sound limb, free prosthetic joint movement underneath the cosmesis and natural fit of clothing over the cosmesis. The results indicate that current cosmesis satisfaction levels of amputees in the United Kingdom are below what the medical device industry and clinical community would desire. The most important cosmesis features identified by the sample can be used to direct future cosmesis design research. The findings will enable the medical device industry to improve cosmesis design in the areas that are important to amputees. The findings also counter anecdotal opinions held by clinicians, providing an opportunity for them to evaluate any preconceptions they harbour and how this might influence their clinical work.
- 1 December 2014
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 38 (6) , 467-473
Open AccessSatisfaction with cosmesis and priorities for cosmesis design reported by lower limb amputees in the United Kingdom
Amputee satisfaction with cosmesis and the importance they place on cosmesis design have not been published in the literature. To investigate the current satisfaction levels of amputees in the United Kingdom with their cosmesis and the importance placed on attributes of cosmesis design to inform future cosmesis redesign. Cross-sectional questionnaire study. Questionnaires were administered to lower limb amputees in the United Kingdom. Satisfaction scores and the overall importance ranking of cosmesis features were calculated. Statistically significant relationships between two demographic, satisfaction or importance variables were tested using Fisher’s exact tests (one-tailed) at a significance level p = 0.05. Between 49% and 64% of respondents reported neutral or dissatisfied opinions with the cosmesis features (greater than 50% for five of the nine features). The three most important features identified were shape matching the cosmesis to the sound limb, free prosthetic joint movement underneath the cosmesis and natural fit of clothing over the cosmesis. The results indicate that current cosmesis satisfaction levels of amputees in the United Kingdom are below what the medical device industry and clinical community would desire. The most important cosmesis features identified by the sample can be used to direct future cosmesis design research. The findings will enable the medical device industry to improve cosmesis design in the areas that are important to amputees. The findings also counter anecdotal opinions held by clinicians, providing an opportunity for them to evaluate any preconceptions they harbour and how this might influence their clinical work.
- 6 October 2012
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 51 (1-2) , 39-47
Ability of modal analysis to detect osseointegration of implants in transfemoral amputees: a physical model study
Owing to the successful use of non-invasive vibration analysis to monitor the progression of dental implant healing and stabilization, it is now being considered as a method to monitor femoral implants in transfemoral amputees. This study uses composite femur–implant physical models to investigate the ability of modal analysis to detect changes at the interface between the implant and bone simulating those that occur during osseointegration. Using electromagnetic shaker excitation, differences were detected in the resonant frequencies and mode shapes of the model when the implant fit in the bone was altered to simulate the two interface cases considered: firm and loose fixation. The study showed that it is beneficial to examine higher resonant frequencies and their mode shapes (rather than the fundamental frequency only) when assessing fixation. The influence of the model boundary conditions on the modal parameters was also demonstrated. Further work is required to more accurately model the mechanical changes occurring at the bone–implant interface in vivo, as well as further refinement of the model boundary conditions to appropriately represent the in vivo conditions. Nevertheless, the ability to detect changes in the model dynamic properties demonstrates the potential of modal analysis in this application and warrants further investigation.
- 6 October 2012
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 51 (1-2) , 39-47
Ability of modal analysis to detect osseointegration of implants in transfemoral amputees: a physical model study
Owing to the successful use of non-invasive vibration analysis to monitor the progression of dental implant healing and stabilization, it is now being considered as a method to monitor femoral implants in transfemoral amputees. This study uses composite femur–implant physical models to investigate the ability of modal analysis to detect changes at the interface between the implant and bone simulating those that occur during osseointegration. Using electromagnetic shaker excitation, differences were detected in the resonant frequencies and mode shapes of the model when the implant fit in the bone was altered to simulate the two interface cases considered: firm and loose fixation. The study showed that it is beneficial to examine higher resonant frequencies and their mode shapes (rather than the fundamental frequency only) when assessing fixation. The influence of the model boundary conditions on the modal parameters was also demonstrated. Further work is required to more accurately model the mechanical changes occurring at the bone–implant interface in vivo, as well as further refinement of the model boundary conditions to appropriately represent the in vivo conditions. Nevertheless, the ability to detect changes in the model dynamic properties demonstrates the potential of modal analysis in this application and warrants further investigation.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 44 (1094687X) , 1600-1603
Evaluation of modal analysis techniques using physical models to detect osseointegration of implants in transfemoral amputees
Non-invasive vibration analysis has been used extensively to monitor the progression of dental implant healing and stabilization. It is now being considered as a method to monitor femoral implants in transfemoral amputees. This paper evaluates two modal analysis excitation methods and investigates their capabilities in detecting changes at the interface between the implant and the bone that occur during osseointegration. Excitation of bone-implant physical models with the electromagnetic shaker provided higher coherence values and a greater number of modes over the same frequency range when compared to the impact hammer. Differences were detected in the natural frequencies and fundamental mode shape of the model when the fit of the implant was altered in the bone. The ability to detect changes in the model dynamic properties demonstrates the potential of modal analysis in this application and warrants further investigation.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 44 (1094687X) , 1600-1603
Evaluation of modal analysis techniques using physical models to detect osseointegration of implants in transfemoral amputees
Non-invasive vibration analysis has been used extensively to monitor the progression of dental implant healing and stabilization. It is now being considered as a method to monitor femoral implants in transfemoral amputees. This paper evaluates two modal analysis excitation methods and investigates their capabilities in detecting changes at the interface between the implant and the bone that occur during osseointegration. Excitation of bone-implant physical models with the electromagnetic shaker provided higher coherence values and a greater number of modes over the same frequency range when compared to the impact hammer. Differences were detected in the natural frequencies and fundamental mode shape of the model when the fit of the implant was altered in the bone. The ability to detect changes in the model dynamic properties demonstrates the potential of modal analysis in this application and warrants further investigation.