Oliver H. Seeck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oliver H. Seeck has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Horst Schulte-Schrepping
Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
2 shared publications A. Beerlink
Hamburger Synchrotronstrahlungslabor am Deutsches Elektronen–Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
1 shared publication- Adrien Néri
University of Lille CNRS INRAE Lille France
1 shared publication - Andriy V. Kityk
Częstochowa University of Technology
1 shared publication - Artem Chanyshev
Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany
1 shared publication - Benjamin M. Ocko
Brookhaven National Laboratory
1 shared publication
Latest Publications
- Open Access
- 23 December 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Directed Self-Assembly of the Organic Semiconductor C8-BTBT-C8 in Anodic Aluminum Oxide Nanopores
Controlling the self-assembly of organic semiconductors at the nanoscale is critical for advancing high-performance electronic and photonic devices, yet remains challenging due to their intrinsic anisotropic crystallization and sensitivity to processing conditions. Here, we demonstrate that cylindrical nanoconfinement within anodic aluminum oxide membranes provides a versatile platform to precisely tune the molecular orientation and phase behavior of the prototypical organic semiconductor 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT-C8). Combining temperature-dependent high-resolution synchrotron X-ray scattering with optical birefringence measurements, we uncover that confinement geometries (pore diameters 25–180 nm) and surface chemistry govern the emergence of distinct smectic A textures, featuring molecular layers either parallel or perpendicular to the pore axis. The competition between axial and radial smectic layering is modulated by pore size, surface hydrophilicity, and thermal history, enabling reversible control over domain orientations and transitions between liquid crystalline and crystalline states. Notably, nanoconfinement stabilizes the smectic phase over an expanded temperature range compared to bulk, while inducing complex multi-domain configurations owing to geometric constraints and anchoring conditions. Our results elucidate fundamental mechanisms by which anisotropic nanoscale confinement directs the self-organization of highly conjugated organic molecules, with implications for optimizing directional charge transport and anisotropic optical responses in organic–inorganic hybrid nanoarchitectures. This study establishes nanoconfinement as a powerful strategy to engineer morphology and functional properties in organic semiconducting materials with nanoscale precision.
- 23 December 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessDirected Self-Assembly of the Organic Semiconductor C8-BTBT-C8 in Anodic Aluminum Oxide Nanopores
Controlling the self-assembly of organic semiconductors at the nanoscale is critical for advancing high-performance electronic and photonic devices, yet remains challenging due to their intrinsic anisotropic crystallization and sensitivity to processing conditions. Here, we demonstrate that cylindrical nanoconfinement within anodic aluminum oxide membranes provides a versatile platform to precisely tune the molecular orientation and phase behavior of the prototypical organic semiconductor 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT-C8). Combining temperature-dependent high-resolution synchrotron X-ray scattering with optical birefringence measurements, we uncover that confinement geometries (pore diameters 25–180 nm) and surface chemistry govern the emergence of distinct smectic A textures, featuring molecular layers either parallel or perpendicular to the pore axis. The competition between axial and radial smectic layering is modulated by pore size, surface hydrophilicity, and thermal history, enabling reversible control over domain orientations and transitions between liquid crystalline and crystalline states. Notably, nanoconfinement stabilizes the smectic phase over an expanded temperature range compared to bulk, while inducing complex multi-domain configurations owing to geometric constraints and anchoring conditions. Our results elucidate fundamental mechanisms by which anisotropic nanoscale confinement directs the self-organization of highly conjugated organic molecules, with implications for optimizing directional charge transport and anisotropic optical responses in organic–inorganic hybrid nanoarchitectures. This study establishes nanoconfinement as a powerful strategy to engineer morphology and functional properties in organic semiconducting materials with nanoscale precision.
- Open Access
- 6 December 2022
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 137 (12) , 1-11
The synchrotron radiation source PETRA III and its future ultra-low-emittance upgrade PETRA IV
PETRA III at DESY is one of the brightest synchrotron radiation sources worldwide. It serves a broad international multidisciplinary user community from academia to industry at currently 25 specialised beamlines. With a storage-ring energy of 6 GeV, it provides mainly hard to high-energy X-rays for versatile experiments in a very broad range of scientific fields. It is ideally suited for an upgrade to the ultra-low emittance source PETRA IV, owing to its large circumference of 2304 m. With a targeted storage ring emittance of $$20 \times 5\,\textrm{pm}^{2}\,\textrm{rad}^{2},$$ PETRA IV will reach spectral brightnesses two to three orders of magnitude higher than today. The unique beam parameters will make PETRA IV the ultimate in situ 3D microscope for biological, chemical, and physical processes helping to address key questions in health, energy, mobility, information technology, and earth and environment.- 6 December 2022
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 137 (12) , 1-11
Open AccessThe synchrotron radiation source PETRA III and its future ultra-low-emittance upgrade PETRA IV
PETRA III at DESY is one of the brightest synchrotron radiation sources worldwide. It serves a broad international multidisciplinary user community from academia to industry at currently 25 specialised beamlines. With a storage-ring energy of 6 GeV, it provides mainly hard to high-energy X-rays for versatile experiments in a very broad range of scientific fields. It is ideally suited for an upgrade to the ultra-low emittance source PETRA IV, owing to its large circumference of 2304 m. With a targeted storage ring emittance of $$20 \times 5\,\textrm{pm}^{2}\,\textrm{rad}^{2},$$ PETRA IV will reach spectral brightnesses two to three orders of magnitude higher than today. The unique beam parameters will make PETRA IV the ultimate in situ 3D microscope for biological, chemical, and physical processes helping to address key questions in health, energy, mobility, information technology, and earth and environment. - Open Access
- 22 February 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (2) , 409-423
Extreme conditions research using the large-volume press at the P61B endstation, PETRA III
Penetrating, high-energy synchrotron X-rays are in strong demand, particularly for high-pressure research in physics, chemistry and geosciences, and for materials engineering research under less extreme conditions. A new high-energy wiggler beamline P61 has been constructed to meet this need at PETRA III in Hamburg, Germany. The first part of the paper offers an overview of the beamline front-end components and beam characteristics. The second part describes the performance of the instrumentation and the latest developments at the P61B endstation. Particular attention is given to the unprecedented high-energy photon flux delivered by the ten wigglers of the PETRA III storage ring and the challenges faced in harnessing this amount of flux and heat load in the beam. Furthermore, the distinctiveness of the world's first six-ram Hall-type large-volume press, Aster-15, at a synchrotron facility is described for research with synchrotron X-rays. Additionally, detection schemes, experimental strategies and preliminary data acquired using energy-dispersive X-ray diffraction and radiography techniques are presented.
- 22 February 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (2) , 409-423
Open AccessExtreme conditions research using the large-volume press at the P61B endstation, PETRA III
Penetrating, high-energy synchrotron X-rays are in strong demand, particularly for high-pressure research in physics, chemistry and geosciences, and for materials engineering research under less extreme conditions. A new high-energy wiggler beamline P61 has been constructed to meet this need at PETRA III in Hamburg, Germany. The first part of the paper offers an overview of the beamline front-end components and beam characteristics. The second part describes the performance of the instrumentation and the latest developments at the P61B endstation. Particular attention is given to the unprecedented high-energy photon flux delivered by the ten wigglers of the PETRA III storage ring and the challenges faced in harnessing this amount of flux and heat load in the beam. Furthermore, the distinctiveness of the world's first six-ram Hall-type large-volume press, Aster-15, at a synchrotron facility is described for research with synchrotron X-rays. Additionally, detection schemes, experimental strategies and preliminary data acquired using energy-dispersive X-ray diffraction and radiography techniques are presented.
- 7 November 2014
- Published by Walter de Gruyter GmbH in Zeitschrift für Physikalische Chemie
- Vol. 228 (10-12) , 1135-1154
X-ray Reflectometry and Related Surface Near X-ray Scattering Methods
- 7 November 2014
- Published by Walter de Gruyter GmbH in Zeitschrift für Physikalische Chemie
- Vol. 228 (10-12) , 1135-1154
X-ray Reflectometry and Related Surface Near X-ray Scattering Methods
- 30 November 2011
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 19 (1) , 30-38
The high-resolution diffraction beamline P08 at PETRA III
The new third-generation synchrotron radiation source PETRA III located at the Deutsches Elektronen-Synchrotron DESY in Hamburg, Germany, has been operational since the second half of 2009. PETRA III is designed to deliver hard X-ray beams with very high brilliance. As one of the first beamlines of PETRA III the high-resolution diffraction beamline P08 is fully operational. P08 is specialized in X-ray scattering and diffraction experiments on solids and liquids where extreme high resolution in reciprocal space is required. The resolving power results in the high-quality PETRA III beam and unique optical elements such as a large-offset monochromator and beryllium lens changers. A high-precision six-circle diffractometer for solid samples and a specially designed liquid diffractometer are installed in the experimental hutch. Regular users have been accepted since summer 2010.
- 30 November 2011
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 19 (1) , 30-38
The high-resolution diffraction beamline P08 at PETRA III
The new third-generation synchrotron radiation source PETRA III located at the Deutsches Elektronen-Synchrotron DESY in Hamburg, Germany, has been operational since the second half of 2009. PETRA III is designed to deliver hard X-ray beams with very high brilliance. As one of the first beamlines of PETRA III the high-resolution diffraction beamline P08 is fully operational. P08 is specialized in X-ray scattering and diffraction experiments on solids and liquids where extreme high resolution in reciprocal space is required. The resolving power results in the high-quality PETRA III beam and unique optical elements such as a large-offset monochromator and beryllium lens changers. A high-precision six-circle diffractometer for solid samples and a specially designed liquid diffractometer are installed in the experimental hutch. Regular users have been accepted since summer 2010.