Tomoya Kobayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tomoya Kobayashi has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Hideyuki Hayakawa
Department of Forensic Medicine, Tsukuba Medical Examiner's Office, Ibaraki Japan
9 shared publicationsSeiji Shiotani
9 shared publicationsKazunori Kaga
Department of Radiological Technology, Tsukuba Medical Center Hospital, Ibaraki Japan
7 shared publicationsKatsumi Miyamoto
5 shared publicationsKazuhiro Homma
5 shared publicationsHajime Saitou
Department of Radiological Technology, Tsukuba Medical Center Hospital, Ibaraki Japan
4 shared publications
Latest Publications
- Open Access
- 30 July 2026
- Published by Elsevier in Forensic Science International
- Vol. 388, 113087
Development of a deep learning–based model for personal identification using postmortem CT and antemortem chest x-rays
- 30 July 2026
- Published by Elsevier in Forensic Science International
- Vol. 388, 113087
Open AccessDevelopment of a deep learning–based model for personal identification using postmortem CT and antemortem chest x-rays
- Open Access
- 31 December 2025
- Published by Elsevier in Journal of Clinical Densitometry
- Vol. 29 (1) , 101666
Osteoporosis prediction from Frontal Lumbar Spine X-rays
- 31 December 2025
- Published by Elsevier in Journal of Clinical Densitometry
- Vol. 29 (1) , 101666
Open AccessOsteoporosis prediction from Frontal Lumbar Spine X-rays
- Open Access
- 27 May 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (1) , 400-410
PlaNet-S: an Automatic Semantic Segmentation Model for Placenta Using U-Net and SegNeXt
This study aimed to develop a fully automated semantic placenta segmentation model that integrates the U-Net and SegNeXt architectures through ensemble learning. A total of 218 pregnant women with suspected placental abnormalities who underwent magnetic resonance imaging (MRI) were enrolled, yielding 1090 annotated images for developing a deep learning model for placental segmentation. The images were standardized and divided into training and test sets. The performance of Placental Segmentation Network (PlaNet-S), which integrates U-Net and SegNeXt within an ensemble framework, was assessed using Intersection over Union (IoU) and counting connected components (CCC) against the U-Net, U-Net + + , and DS-transUNet. PlaNet-S had significantly higher IoU (0.78, SD = 0.10) than that of U-Net (0.73, SD = 0.13) ( p < 0.005) and DS-transUNet (0.64, SD = 0.16) ( p < 0.005), while the difference with U-Net + + (0.77, SD = 0.12) was not statistically significant. The CCC for PlaNet-S was significantly higher than that for U-Net ( p < 0.005), U-Net + + ( p < 0.005), and DS-transUNet ( p < 0.005), matching the ground truth in 86.0%, 56.7%, 67.9%, and 20.9% of the cases, respectively. PlaNet-S achieved higher IoU than U-Net and DS-transUNet, and comparable IoU to U-Net + + . Moreover, PlaNet-S significantly outperformed all three models in CCC, indicating better agreement with the ground truth. This model addresses the challenges of time-consuming physician-assisted manual segmentation and offers the potential for diverse applications in placental imaging analyses.
- 27 May 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (1) , 400-410
Open AccessPlaNet-S: an Automatic Semantic Segmentation Model for Placenta Using U-Net and SegNeXt
This study aimed to develop a fully automated semantic placenta segmentation model that integrates the U-Net and SegNeXt architectures through ensemble learning. A total of 218 pregnant women with suspected placental abnormalities who underwent magnetic resonance imaging (MRI) were enrolled, yielding 1090 annotated images for developing a deep learning model for placental segmentation. The images were standardized and divided into training and test sets. The performance of Placental Segmentation Network (PlaNet-S), which integrates U-Net and SegNeXt within an ensemble framework, was assessed using Intersection over Union (IoU) and counting connected components (CCC) against the U-Net, U-Net + + , and DS-transUNet. PlaNet-S had significantly higher IoU (0.78, SD = 0.10) than that of U-Net (0.73, SD = 0.13) ( p < 0.005) and DS-transUNet (0.64, SD = 0.16) ( p < 0.005), while the difference with U-Net + + (0.77, SD = 0.12) was not statistically significant. The CCC for PlaNet-S was significantly higher than that for U-Net ( p < 0.005), U-Net + + ( p < 0.005), and DS-transUNet ( p < 0.005), matching the ground truth in 86.0%, 56.7%, 67.9%, and 20.9% of the cases, respectively. PlaNet-S achieved higher IoU than U-Net and DS-transUNet, and comparable IoU to U-Net + + . Moreover, PlaNet-S significantly outperformed all three models in CCC, indicating better agreement with the ground truth. This model addresses the challenges of time-consuming physician-assisted manual segmentation and offers the potential for diverse applications in placental imaging analyses.
- Open Access
- 30 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 5384-5388
Usefulness of fat attenuation index in postmortem CT for identifying responsible vessels in acute coronary syndromes: A case report
- 30 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 5384-5388
Open AccessUsefulness of fat attenuation index in postmortem CT for identifying responsible vessels in acute coronary syndromes: A case report
- 1 March 2021
- Published by Elsevier in Forensic Imaging
- Vol. 24
Star-trail artifacts of the advanced-putrefied brain on postmortem CT
- 1 March 2021
- Published by Elsevier in Forensic Imaging
- Vol. 24
Star-trail artifacts of the advanced-putrefied brain on postmortem CT
- 1 December 2020
- Published by Elsevier in Forensic Imaging
- Vol. 23
Noise reduction effect of computed tomography by image summation method (fused CT): Phantom study
- 1 December 2020
- Published by Elsevier in Forensic Imaging
- Vol. 23
Noise reduction effect of computed tomography by image summation method (fused CT): Phantom study
- 1 December 2020
- Published by Elsevier in Forensic Imaging
- Vol. 23
Skin temperature increase after whole body postmortem magnetic resonance imaging
- 1 December 2020
- Published by Elsevier in Forensic Imaging
- Vol. 23
Skin temperature increase after whole body postmortem magnetic resonance imaging
- Open Access
- 1 January 2015
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 14 (4) , 251-255
Optimization of Inversion Time for Postmortem Fluid-attenuated Inversion Recovery (FLAIR) MR Imaging at 1.5T: Temperature-based Suppression of Cerebrospinal Fluid
Signal intensity (SI) and image contrast on postmortem magnetic resonance (MR) imaging are different from those of imaging of living bodies. We sought to suppress the SI of cerebrospinal fluid (CSF) sufficiently for fluid-attenuated inversion recovery (FLAIR) sequence in postmortem MR (PMMR) imaging by optimizing inversion time (TI). We subject 28 deceased patients to PMMR imaging 3 to 113 hours after confirmation of death (mean, 27.4 hrs.). PMMR imaging was performed at 1.5 tesla, and T1 values of CSF were measured with maps of relaxation time. Rectal temperatures (RT) measured immediately after PMMR imaging ranged from 6 to 32°C (mean, 15.4°C). We analyzed the relationship between T1 and RT statistically using Pearson's correlation coefficient. We obtained FLAIR images from one cadaver using both a TI routinely used for living bodies and an optimized TI calculated from the RT. T1 values of CSF ranged from 2159 to 4063 ms (mean 2962.4), and there was a significantly positive correlation between T1 and RT (r = 0.96, P < 0.0001). The regression expression for the relationship was T1 = 74.4 * RT + 1813 for a magnetic field strength of 1.5T. The SI of CSF was effectively suppressed with the optimized TI (0.693 * T1), namely, TI = 0.693 * (77.4 * RT + 1813). Use of the TI calculated from the linear regression of the T1 and RT optimizes the FLAIR sequence of PMMR imaging.
- 1 January 2015
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 14 (4) , 251-255
Open AccessOptimization of Inversion Time for Postmortem Fluid-attenuated Inversion Recovery (FLAIR) MR Imaging at 1.5T: Temperature-based Suppression of Cerebrospinal Fluid
Signal intensity (SI) and image contrast on postmortem magnetic resonance (MR) imaging are different from those of imaging of living bodies. We sought to suppress the SI of cerebrospinal fluid (CSF) sufficiently for fluid-attenuated inversion recovery (FLAIR) sequence in postmortem MR (PMMR) imaging by optimizing inversion time (TI). We subject 28 deceased patients to PMMR imaging 3 to 113 hours after confirmation of death (mean, 27.4 hrs.). PMMR imaging was performed at 1.5 tesla, and T1 values of CSF were measured with maps of relaxation time. Rectal temperatures (RT) measured immediately after PMMR imaging ranged from 6 to 32°C (mean, 15.4°C). We analyzed the relationship between T1 and RT statistically using Pearson's correlation coefficient. We obtained FLAIR images from one cadaver using both a TI routinely used for living bodies and an optimized TI calculated from the RT. T1 values of CSF ranged from 2159 to 4063 ms (mean 2962.4), and there was a significantly positive correlation between T1 and RT (r = 0.96, P < 0.0001). The regression expression for the relationship was T1 = 74.4 * RT + 1813 for a magnetic field strength of 1.5T. The SI of CSF was effectively suppressed with the optimized TI (0.693 * T1), namely, TI = 0.693 * (77.4 * RT + 1813). Use of the TI calculated from the linear regression of the T1 and RT optimizes the FLAIR sequence of PMMR imaging.