Hasina Yasmin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hasina Yasmin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Kuni Ohtomo
The University of Tokyo
2 shared publicationsNaoto Hayashi
The University of Tokyo
2 shared publicationsOsamu Abe
The University of Tokyo
2 shared publicationsShigeki Aoki
Juntendo University School of Medicine
2 shared publicationsYoshitaka Masutani
The University of Tokyo
2 shared publicationsHiroyuki Kabasawa
GE Healthcare Japan Corporation
1 shared publication
Latest Publications
- 30 January 2010
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 28 (1) , 27-33
Motion-robust diffusion tensor acquisition at routine 3T magnetic resonance imaging
We compared different acquisition and reconstruction methods in phantom and human studies in the clinical setting to validate our hypothesis that optimizing the k-space acquisition and reconstruction method could decrease motion artifacts. Diffusion tensor images of a water phantom were obtained with three table displacement magnitudes: 1 mm, 2 mm, and 3 mm. Images were reconstructed using homodyne and zero-fill reconstruction. Overscanning in 8- and 16-ky lines was tested. We performed visual assessment of the artifacts using reconstructed coronal images and analyzed them with Wilcoxon signed-ranks test both for phantom and human studies. Also, fractional anisotropy (FA) changes between acquisition methods were compared. Artifacts due to smaller displacement (1 and 2 mm) were significantly reduced in 16-ky overscan with zero filling. The Wilcoxon signed-ranks test showed significant differences (P < 0.031 for reconstruction methods and P < 0.016 for overscanning methods). FA changes were statistically significant (P < 0.037; Student’s t-test). The Wilcoxon signed-ranks test showed significant reductions (P < 0.005) in the human study. Motion-induced artifacts can be reduced by optimizing acquisition and reconstruction methods. The techniques described in this study offer an effective method for robust estimation of diffusion tensor in the presence of motion-related artifactual data points.
- 30 January 2010
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 28 (1) , 27-33
Motion-robust diffusion tensor acquisition at routine 3T magnetic resonance imaging
We compared different acquisition and reconstruction methods in phantom and human studies in the clinical setting to validate our hypothesis that optimizing the k-space acquisition and reconstruction method could decrease motion artifacts. Diffusion tensor images of a water phantom were obtained with three table displacement magnitudes: 1 mm, 2 mm, and 3 mm. Images were reconstructed using homodyne and zero-fill reconstruction. Overscanning in 8- and 16-ky lines was tested. We performed visual assessment of the artifacts using reconstructed coronal images and analyzed them with Wilcoxon signed-ranks test both for phantom and human studies. Also, fractional anisotropy (FA) changes between acquisition methods were compared. Artifacts due to smaller displacement (1 and 2 mm) were significantly reduced in 16-ky overscan with zero filling. The Wilcoxon signed-ranks test showed significant differences (P < 0.031 for reconstruction methods and P < 0.016 for overscanning methods). FA changes were statistically significant (P < 0.037; Student’s t-test). The Wilcoxon signed-ranks test showed significant reductions (P < 0.005) in the human study. Motion-induced artifacts can be reduced by optimizing acquisition and reconstruction methods. The techniques described in this study offer an effective method for robust estimation of diffusion tensor in the presence of motion-related artifactual data points.
- 7 August 2009
- Published by Springer Nature in Neuroradiology
- Vol. 51 (12) , 831-840
Tract-specific analysis of white matter pathways in healthy subjects: a pilot study using diffusion tensor MRI
Introduction To date, very scant data is available regarding normal diffusion properties of white matter (WM) fibers. The present study aimed to initiate the establishment of a database of normal diffusion tensor metrics of cerebral WM fibers, including the uncinate fasciculus (UF), posterior cingulum (PC), fornix, and corticospinal tract (CST) for healthy adults using tract-specific analysis by diffusion tensor tractography (DTT). We also attempted to clarify whether age and laterality exerted any effects on this study group. Methods DTT of WM fibers were generated for 100 healthy subjects, then mean diffusivity (MD) and fractional anisotropy (FA) of the tracts were measured. Pearson correlation analysis was used to evaluate age relationships. Paired t testing was used to compare hemispheric asymmetry. Interobserver correlation tests were also performed. Results Our results showed FA values for UF (right, 0.42 ± 0.03; left, 0.40±0.03), PC (0.51 ± 0.06, 0.52 ± 0.06), fornix (0.37 ± 0.06, 0.38 ± 0.06), CST (0.70 ± 0.06, 0.69 ± 0.07), and MD values for UF (0.81 ± 0.03, 0.82 ± 0.04), PC (0.72 ± 0.03, 0.72 ± 0.04), fornix (1.86 ± 0.32, 1.94 ± 0.37), and CST (0.72 ± 0.03, 0.74 ± 0.04). We identified a significant positive correlation between age and MD in the right UF and bilateral fornices, and a negative correlation between age and FA in bilateral fornices. Hemispheric asymmetry was observed in FA of UF (right > left) and MD of CST (left > right). Conclusions The results constitute a normative dataset for diffusion parameters of four WM tracts that can be used to identify, characterize, and establish the significance of changes in diseases affecting specific tracts.
- 7 August 2009
- Published by Springer Nature in Neuroradiology
- Vol. 51 (12) , 831-840
Tract-specific analysis of white matter pathways in healthy subjects: a pilot study using diffusion tensor MRI
Introduction To date, very scant data is available regarding normal diffusion properties of white matter (WM) fibers. The present study aimed to initiate the establishment of a database of normal diffusion tensor metrics of cerebral WM fibers, including the uncinate fasciculus (UF), posterior cingulum (PC), fornix, and corticospinal tract (CST) for healthy adults using tract-specific analysis by diffusion tensor tractography (DTT). We also attempted to clarify whether age and laterality exerted any effects on this study group. Methods DTT of WM fibers were generated for 100 healthy subjects, then mean diffusivity (MD) and fractional anisotropy (FA) of the tracts were measured. Pearson correlation analysis was used to evaluate age relationships. Paired t testing was used to compare hemispheric asymmetry. Interobserver correlation tests were also performed. Results Our results showed FA values for UF (right, 0.42 ± 0.03; left, 0.40±0.03), PC (0.51 ± 0.06, 0.52 ± 0.06), fornix (0.37 ± 0.06, 0.38 ± 0.06), CST (0.70 ± 0.06, 0.69 ± 0.07), and MD values for UF (0.81 ± 0.03, 0.82 ± 0.04), PC (0.72 ± 0.03, 0.72 ± 0.04), fornix (1.86 ± 0.32, 1.94 ± 0.37), and CST (0.72 ± 0.03, 0.74 ± 0.04). We identified a significant positive correlation between age and MD in the right UF and bilateral fornices, and a negative correlation between age and FA in bilateral fornices. Hemispheric asymmetry was observed in FA of UF (right > left) and MD of CST (left > right). Conclusions The results constitute a normative dataset for diffusion parameters of four WM tracts that can be used to identify, characterize, and establish the significance of changes in diseases affecting specific tracts.