Yanzhou Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanzhou Zhou has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Bo Dong
2 shared publicationsChunDi LIN
1 shared publicationCi Chen
1 shared publicationCong Shi
Faculty of Automation, Guangdong University of Technology, Guangzhou, Guangdong 510006, China
1 shared publication- Jingsong He
School of Microelectronics, University of Science and Technology of China, Hefei, China
1 shared publication Jinxiong Xu
Faculty of Automation, Guangdong University of Technology, Guangzhou, Guangdong, China
1 shared publication
Latest Publications
- 1 September 2017
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 96, 35-38
Dual-channel phase-contrast spectral optical coherence tomography for simultaneously measuring axial and normal to B-scan off-axial displacements
- 1 September 2017
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 96, 35-38
Dual-channel phase-contrast spectral optical coherence tomography for simultaneously measuring axial and normal to B-scan off-axial displacements
- 5 July 2013
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (20) , 4890-4897
Improvement of the depth resolution in depth-resolved wavenumber-scanning interferometry using multiple uncorrelated wavenumber bands
In this article, we provide a method to improve the depth resolution of wide-field depth-resolved wavenumber-scanning interferometry (DRWSI), because its depth resolution is limited by the range of the wavenumber scanning and mode hopping of the light source. An optical wedge is put into the optical path to measure the series of the wavenumber on time using a 2D spatial Fourier transform (FT) of the interferograms. Those uncorrelated multiple bands of the wavenumbers due to mode hopping of the diode laser can be synthesized into one band, to enlarge the range of the wavenumber scanning. A random-sampling FT is put forward to evaluate the distribution of frequencies and phases of the multiple surfaces measured. The benefit is that the depth resolution of the DRWSI is enhanced significantly with a higher signal-to-noise ratio. Because of its simplicity and practicability, this method broadens the way to employing multiple different lasers or lasers with mode hopping as the light sources in the DRWSI.
- 5 July 2013
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (20) , 4890-4897
Improvement of the depth resolution in depth-resolved wavenumber-scanning interferometry using multiple uncorrelated wavenumber bands
In this article, we provide a method to improve the depth resolution of wide-field depth-resolved wavenumber-scanning interferometry (DRWSI), because its depth resolution is limited by the range of the wavenumber scanning and mode hopping of the light source. An optical wedge is put into the optical path to measure the series of the wavenumber on time using a 2D spatial Fourier transform (FT) of the interferograms. Those uncorrelated multiple bands of the wavenumbers due to mode hopping of the diode laser can be synthesized into one band, to enlarge the range of the wavenumber scanning. A random-sampling FT is put forward to evaluate the distribution of frequencies and phases of the multiple surfaces measured. The benefit is that the depth resolution of the DRWSI is enhanced significantly with a higher signal-to-noise ratio. Because of its simplicity and practicability, this method broadens the way to employing multiple different lasers or lasers with mode hopping as the light sources in the DRWSI.
- 1 May 2013
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Physica, Mechanica & Astronomica
- Vol. 43 (6) , 718-724
RMB identification using the polar phasor approach on the time-resolved fluorescence
One of the key technologies to identify RMB banknotes is to detect its paper tissue. In this paper, using two-photon fluorescence confocal microscopy, a new RMB identification technology based on the polar phasor approach of the fluorescence lifetime is put forwards. This is the first time that the polar phasor approach has been applied to analyze the average fluorescence lifetime of the genuine and counterfeit RMB banknotes, respectively. The time-resolved fluorescence process of the genuine banknote conforms to the double-exponential decay model. There are almost no differences among the average fluorescence lifetimes of the various denominations of RMB genuine banknotes; however, the difference of the average fluorescence lifetimes between the genuine and counterfeit banknotes is significant. The experimental results show that the RMB identification technology cannot be affected by the circulation time, mechanical crease, injury, and surface pollutant on the banknotes. The measurement method is sensitive, and the device is reliable; therefore, it can identify the RMB genuine and counterfeit banknotes effectively and practically.
- 1 May 2013
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Physica, Mechanica & Astronomica
- Vol. 43 (6) , 718-724
RMB identification using the polar phasor approach on the time-resolved fluorescence
One of the key technologies to identify RMB banknotes is to detect its paper tissue. In this paper, using two-photon fluorescence confocal microscopy, a new RMB identification technology based on the polar phasor approach of the fluorescence lifetime is put forwards. This is the first time that the polar phasor approach has been applied to analyze the average fluorescence lifetime of the genuine and counterfeit RMB banknotes, respectively. The time-resolved fluorescence process of the genuine banknote conforms to the double-exponential decay model. There are almost no differences among the average fluorescence lifetimes of the various denominations of RMB genuine banknotes; however, the difference of the average fluorescence lifetimes between the genuine and counterfeit banknotes is significant. The experimental results show that the RMB identification technology cannot be affected by the circulation time, mechanical crease, injury, and surface pollutant on the banknotes. The measurement method is sensitive, and the device is reliable; therefore, it can identify the RMB genuine and counterfeit banknotes effectively and practically.
- 8 June 2010
- Published by Springer Nature in Journal of Fluorescence
- Vol. 21 (1) , 11-15
Global Analysis of Dynamic Fluorescence Anisotropy by a Polarized Phasor Approach
Recently, the graphical analysis of the fluorescence lifetime imaging using the phasor approach has been highlight, and a series of the reports have made it on the way for the applications by the nonprofessionals. In this paper, we put forward a similar theory validated by the experiments for the dynamic fluorescence anisotropy imaging. By subtracting the perpendicular component from the parallel one in the frequency-domain polarization measurement, we deduce a new analytical expression about the fluorescence joint time, and find that as much as the fluorophore is a single exponential decay and \( {r_\infty } \) is equal to zero, △I(t) is a single exponential decay with the time constant X as well, and the center of its histograms is located on the semicircle in the polarized phasor plot. In the end, we conclude that the fluorescence joint time is the best parameter to weigh the fluorescence dynamics for the macromolecules.- 8 June 2010
- Published by Springer Nature in Journal of Fluorescence
- Vol. 21 (1) , 11-15
Global Analysis of Dynamic Fluorescence Anisotropy by a Polarized Phasor Approach
Recently, the graphical analysis of the fluorescence lifetime imaging using the phasor approach has been highlight, and a series of the reports have made it on the way for the applications by the nonprofessionals. In this paper, we put forward a similar theory validated by the experiments for the dynamic fluorescence anisotropy imaging. By subtracting the perpendicular component from the parallel one in the frequency-domain polarization measurement, we deduce a new analytical expression about the fluorescence joint time, and find that as much as the fluorophore is a single exponential decay and \( {r_\infty } \) is equal to zero, △I(t) is a single exponential decay with the time constant X as well, and the center of its histograms is located on the semicircle in the polarized phasor plot. In the end, we conclude that the fluorescence joint time is the best parameter to weigh the fluorescence dynamics for the macromolecules.