Matti Malinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matti Malinen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Tomi Huttunen
University of Kuopio
2 shared publicationsJari P. Kaipio
University of Kuopio
1 shared publication- Jari P. Kaipio
Department of Mathematics, University of Auckland, Auckland, New Zealand
1 shared publication - Joonas Sorvari
VTT Technical Research Centre of Finland
1 shared publication Kullervo Hynynen
1 shared publication
Latest Publications
- 19 December 2007
- Published by Springer Nature
- p. 169-195
Optimal control in high intensity focused ultrasound surgery
- 19 December 2007
- Published by Springer Nature
- p. 169-195
Optimal control in high intensity focused ultrasound surgery
- 17 October 2007
- Published by Springer Nature in Mechanics of Time-Dependent Materials
- Vol. 11 (2) , 143-157
On the direct estimation of creep and relaxation functions
- 17 October 2007
- Published by Springer Nature in Mechanics of Time-Dependent Materials
- Vol. 11 (2) , 143-157
On the direct estimation of creep and relaxation functions
- 26 April 2004
- Published by Wiley in Medical Physics
- Vol. 31 (5) , 1296-1307
Simulation study for thermal dose optimization in ultrasound surgery of the breast
In this paper the previously published optimization algorithm for thermal dose optimization is tested with numerical simulations. The simulations concern the thermal dose optimization in ultrasound surgery of the breast. The optimization algorithm is extended by setting the inequality constraint approximations to temperature in healthy tissue as well as in tumor region. In addition, the simulations are accomplished in realistic 3D geometry with varying thermal parameters. Another topic of the paper is to show the potential of the hemispherical phased array applicator for ultrasound surgery of the breast. With such an applicator larger tissue volumes can be treated with shorter time as compared to single element transducers. In simulations the geometrical focus of the applicator was placed mechanically in the middle of the treatable region. The whole tumor region was then scanned electrically by changing the phase of the emitted wave from individual elements. The simulations indicate that a feasible treatment plan can be achieved. In simulated cases the desired thermal dose was achieved for tumors with diameter from 1.5 to 2.4 cm, depending on the position of tumor. The maximum temperature limitations of 45 °C in healthy region and 80 °C in tumor region can be maintained in all simulations.
- 26 April 2004
- Published by Wiley in Medical Physics
- Vol. 31 (5) , 1296-1307
Simulation study for thermal dose optimization in ultrasound surgery of the breast
In this paper the previously published optimization algorithm for thermal dose optimization is tested with numerical simulations. The simulations concern the thermal dose optimization in ultrasound surgery of the breast. The optimization algorithm is extended by setting the inequality constraint approximations to temperature in healthy tissue as well as in tumor region. In addition, the simulations are accomplished in realistic 3D geometry with varying thermal parameters. Another topic of the paper is to show the potential of the hemispherical phased array applicator for ultrasound surgery of the breast. With such an applicator larger tissue volumes can be treated with shorter time as compared to single element transducers. In simulations the geometrical focus of the applicator was placed mechanically in the middle of the treatable region. The whole tumor region was then scanned electrically by changing the phase of the emitted wave from individual elements. The simulations indicate that a feasible treatment plan can be achieved. In simulated cases the desired thermal dose was achieved for tumors with diameter from 1.5 to 2.4 cm, depending on the position of tumor. The maximum temperature limitations of 45 °C in healthy region and 80 °C in tumor region can be maintained in all simulations.