SSSalvatore J. Salamone

Salvatore J. Salamone

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Salvatore J. Salamone has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Profiles of Urine Samples Taken from Ecstasy Users at Rave Parties: Analysis by Immunoassays, HPLC, and GC-MS

    by Huiru Zhao, Rudolf Brenneisen, Andre Scholer, A.J. McNally, Mahmoud A. ElSohly, Timothy P. Murphy, Salvatore J. Salamone

    The abuse of the designer amphetamines such as 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) is increasing throughout the world. They have become popular drugs, especially at all-night techno dance parties (Raves), and their detection is becoming an important issue. Presently, there are no MDMA- or MDA-specific immunoassays on the market, and detection of the designer amphetamines is dependent upon the use of commercially available amphetamine assays. The success of this approach has been difficult to assess because of the general unavailability of significant numbers of samples from known drug users. The objectives of the present study are to characterize the drug content of urine samples from admitted Ecstasy users by chromatographic methods and to assess the ability of the available amphetamine/methamphetamine immunoassays to detect methylenedioxyamphetamines. We found that, when analyzed by high-performance liquid chromatography with diode-array detection (HPLC-DAD), 64% of 70 urine samples (by gas chromatography-mass spectrometry [GC-MS]: 88% of 64 urine samples) obtained from Rave attendees contained MDMA and/or 3,4-methylenedioxyamphetamine (MDA) alone or in combination with amphetamine, methamphetamine, or other designer amphetamines such as 3,4-methylenedioxyethylamphetamine (MDEA). This suggests that the majority of the Ravers are multi-drug users. At the manufacturer's suggested cutoffs, the Abbott TDx Amphetamine/Methamphetamine II and the new Roche HS Amphetamine/MDMA assays demonstrated greater detection sensitivity for MDMA than the other amphetamine immunoassays tested (Abuscreen OnLine Hitachi AMPS, Abuscreen OnLine Integra AMPS, Abuscreen OnLine Integra AMPSX, CEDIA AMPS, and EMIT II AMPS). There is 100% agreement between each of the two immunoassays with the reference chromatographic methods, HPLC-DAD and GC-MS, for the detection of methylenedioxyamphetamines.


  • Open Access

    New Fluorescence Polarization Immunoassays for Analysis of Barbiturates and Benzodiazepines in Serum and Urine: Performance Characteristics

    by K. S. Schwenzer, R. Pearlman, M. Tsilimidos, S. J. Salamone, R. C. Cannon, S. H. Y. Wong, S. B. Gock, J. J. Jentzen

    The performance of the new fluorescence polarization immunoassay reagents Cassette COBAS® INTEGRA Serum Benzodiazepines assay (SBENZ) and Cassette Serum Barbiturates assay (SBARB) was evaluated as compared to other immunoassays (Abbott TDx® Serum Benzodiazepines, Abbott TDx Urine Benzodiazepines, Behring EMIT® Serum Benzodiazepines, Abbott ADx® Serum Barbiturates, Behring EMIT Serum Barbiturates, and the COBAS INTEGRA Barbiturates (BARB) urine assay) and gas chromatography-mass spectrometry (GC-MS). Recoveries of nordiazepam and secobarbital using the SBENZ and SBARB assays, respectively, were equivalent for serum, plasma, and urine. Cross-reactivities of structurally related benzodiazepines, barbiturates, and their metabolites were very similar in serum and urine for the SBENZ and SBARB assays. Precision was within 5.4% for SBENZ serum and within 11% from 10 to 100 ng/mL for urine. Precision was within 5% for SBARB serum and within 7% from 136 to 277 ng/mL for the urine application. The standard curves for SBENZ and SBARB were stable for at least 16 weeks with the reagents stored open on the COBAS INTEGRA analyzer. Clinical comparison of the SBENZ serum assay indicated an increased pickup rate, as confirmed by GC-MS, compared to TDx and EMIT. The diagnostic sensitivities of the SBENZ serum application, TDx, and EMIT versus GC-MS were 100%, 89%, and 36%, respectively. The diagnostic specificities were 71%, 79%, and 100%, respectively. The diagnostic sensitivities of the SBENZ urine application and TDx versus GC-MS were 100% and the diagnostic specificities were 88%. The increased positive pick-up of the SBENZ assay compared to the other immunoassays is most probably due to the difference in the limit of detection (LOD) and the increased cross-reactivity for the low-dose benzodiazepines. Clinical comparison of the SBARB serum assay indicated an increased positive pick-up rate, as confirmed by GC-MS. The diagnostic sensitivities of the SBARB serum application, ADx, and EMIT versus GC-MS were 96%, 65%, and 35%, respectively. The diagnostic specificities were all 100%. The diagnostic sensitivities for the SBARB urine application and BARB versus GC-MS were all 100%, and the diagnostic specificities were all 91%. The SBENZ and SBARB kits demonstrated increased sensitivity for the detection of benzodiazepines and barbiturates in both serum and urine compared to the other immunoassays.


  • Open Access

    Prevalence of Drugs Used in Cases of Alleged Sexual Assault

    by M.A. ElSohly, S.J. Salamone

    In recent years, there has been an increase in the number of reports in the U.S. of the use of drugs, often in conjunction with alcohol, to commit sexual assault. A study was undertaken to assess the prevalence of drug use in sexual assault cases in which substances are suspected of being involved. Law enforcement agencies, emergency rooms, and rape crisis centers across the U.S. were offered the opportunity to submit urine samples collected from victims of alleged sexual assault, where drug use was suspected, for analysis of alcohol and drugs which may be associated with sexual assault. Each sample was tested by immunoassay for amphetamines, barbiturates, benzodiazepines, cocaine metabolite (benzoylecgonine), cannabinoids, methaqualone, opiates, phencyclidine and propoxyphene. The positive screen results were confirmed by gas chromatography-mass spectroscopy (GC-MS). In addition, each sample was tested for flunitrazepam metabolites and gamma-hydroxybutyrate (GHB) by GC-MS and for ethanol by gas chromatography-flame ionization detection (GC-FID). Over a 26-month period, 1179 samples were collected and analyzed from 49 states, Puerto Rico, and the District of Columbia. The states sending the most samples were California (183), Texas (119), Florida (61), Pennsylvania (61), New York (61), Minnesota (50), Illinois (47), Indiana (44), Michigan (40), Maryland (37), Virginia (32), and Massachusetts (31). Four-hundred sixty eight of the samples were found negative for all the substances tested; 451 were positive for ethanol, 218 for cannabinoids, 97 for benzoylecgonine, 97 for benzodiazepines, 51 for amphetamines, 48 for GHB, 25 for opiates, 17 for propoxyphene, and 12 for barbiturates. There were no samples identified as positive for phencydidine or methaqualone. In addition, 35% of the drug-positive samples contained multiple drugs. This study indicates that, with respect to alleged sexual assault cases, the prevalence of ethanol is very high, followed by cannabinoids, cocaine, benzodiazepines, amphetamines, and GHB. Although only a couple of substances have been implicated with sexual assault, this study has shown that almost 20 different substances have been associated with this crime. This study also raises the concern of illicit and licit drug use in sexual assault cases and suggests the need to test for a range of drugs in these cases. It also highlights the need to test for GHB, which is not generally tested for in a normal toxicology screen.


  • Open Access

    Evaluation of the OnLine Immunoassay for Propoxyphene: Comparison to EMIT II and GC-MS

    by A. J. McNally, I. Pilcher, R. Wu, S. J. Salamone, S. Brewington, J. W. King, J. Irving

    A study was conducted to compare the clinical sensitivity of the OnLine and EMIT II assays for propoxyphene (PPX) use in human urine. A total of 5138 random clinical samples were evaluated by both OnLine and EMIT II. Samples that were positive for each immunoassay were confirmed for PPX and norpropoxyphene (NPPX) by gas chromatography-mass spectrometry (GC-MS). There were 14 samples that were identified positive by both immunoassays and confirmed positive by GC-MS. An additional six samples were positive by OnLine, negative by EMIT II, and confirmed positive by GC-MS. There was one unconfirmed positive sample identified by each immunoassay, and 5116 samples were identified as negative by both immunoassays. The increased sensitivity by OnLine can be attributed to the cross reactivity of the OnLine antibody, which is higher than the cross reactivity of the EMIT II antibody for NPPX (77% versus 7%, respectively). The high concentrations of NPPX, relative to those of PPX, found in all of the clinical samples suggest that laboratories that currently confirm for PPX should confirm for NPPX in order to obtain a better correlation between immunoassay results and GC-MS confirmations.


  • Open Access

    An OnLine Immunoassay for LSD: Comparison with GC-MS and the Abuscreen(R) RIA

    by A. J. McNally, K. Goc-Szkutnicka, Z. Li, I. Pilcher, S. Polakowski, S. J. Salamone

    A homogenous microparticle-based immunoassay has been developed for the detection of d-lysergic acid diethylamide (LSD) in human urine using the OnLine® technology. This immunoassay is based on the principle of the kinetic interaction of microparticles in a solution where the drug content of the urine is directly proportional to the inhibition of the microparticle aggregation. Antibodies to LSD were obtained by immunizing goats with an LSD analogue derivatized through the indole nitrogen and conjugated to bovine thyroglobulin. The assay cutoff is 0.5 ng/mL LSD, and the clinical sensitivity for the detection of LSD and its metabolites in human urine samples is equivalent to the LSD Abuscreen® RIA. Thirty-one samples previously screened LSD positive by Abuscreen RIA and confirmed by gas chromatography-mass spectrometry were analyzed by the Abuscreen OnLine LSD and Abuscreen LSD RIA assays. All thirty-one samples screened positive in the Abuscreen OnLine and Abuscreen RIA. OnLine's cross-reactivity to nor-LSD is greater than thirty-five percent; other structurally related compounds have similar cross-reactivity to that of the Abuscreen RIA. One thousand presumed negative urine samples were also analyzed; 992 (99.2%) of these gave negative results. The eight OnLine positive samples from this set were found to be negative by Abuscreen RIA. Typical qualitative within-run precision on the Hitachi 717 (at x = cutoff of 0.5 ng/mL; 0.5x, 1.0x, and 1.5x) was found to be less than 2.5%. Between-run precision was less than 3.0%.