KKKavita Kumareswaran

Kavita Kumareswaran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kavita Kumareswaran has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Roman Hovorka

    Institute of Metabolic Science-Metabolic Research Laboratories, University of Cambridge, Cambridge, U.K.

    5 shared publications
  • Marianna Nodale

    Cambridge Clinical Trials Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK

    3 shared publications
  • Daniela Elleri

    University of Cambridge Metabolic Research Laboratories and NIHR Cambridge Biomedical Research Centre, Cambridge, U.K.

    2 shared publications
  • Helen R. Murphy

    University of Cambridge Metabolic Research Laboratories and NIHR Cambridge Biomedical Research Centre, Cambridge, U.K.

    2 shared publications
  • Janet M. Allen

    University of Cambridge Metabolic Research Laboratories and NIHR Cambridge Biomedical Research Centre, Cambridge, U.K.

    2 shared publications
  • Karen Caldwell

    University of Cambridge Metabolic Research Laboratories and NIHR Cambridge Biomedical Research Centre, Cambridge, U.K.

    2 shared publications

Latest Publications

  • Open Access

    Feasibility of fully automated closed-loop glucose control using continuous subcutaneous glucose measurements in critical illness: a randomized controlled trial

    by Lalantha Leelarathna, Shane W English, Hood Thabit, Karen Caldwell, Janet M Allen, Kavita Kumareswaran, Malgorzata E Wilinska, Marianna Nodale, Jasdip Mangat, Mark L Evans, et al.

    Introduction: Closed-loop (CL) systems modulate insulin delivery according to glucose levels without nurse input. In a prospective randomized controlled trial, we evaluated the feasibility of an automated closed-loop approach based on subcutaneous glucose measurements in comparison with a local sliding-scale insulin-therapy protocol. Methods: Twenty-four critically ill adults (predominantly trauma and neuroscience patients) with hyperglycemia (glucose, ≥10 mM) or already receiving insulin therapy, were randomized to receive either fully automated closed-loop therapy (model predictive control algorithm directing insulin and 20% dextrose infusion based on FreeStyle Navigator continuous subcutaneous glucose values, n = 12) or a local protocol (n = 12) with intravenous sliding-scale insulin, over a 48-hour period. The primary end point was percentage of time when arterial blood glucose was between 6.0 and 8.0 mM. Results: The time when glucose was in the target range was significantly increased during closed-loop therapy (54.3% (44.1 to 72.8) versus 18.5% (0.1 to 39.9), P = 0.001; median (interquartile range)), and so was time in wider targets, 5.6 to 10.0 mM and 4.0 to 10.0 mM (P ≤ 0.002), reflecting a reduced glucose exposure >8 and >10 mM (P ≤ 0.002). Mean glucose was significantly lower during CL (7.8 (7.4 to 8.2) versus 9.1 (8.3 to 13.0] mM; P = 0.001) without hypoglycemia (M) during either therapy. Conclusions: Fully automated closed-loop control based on subcutaneous glucose measurements is feasible and may provide efficacious and hypoglycemia-free glucose control in critically ill adults. Trial Registration: ClinicalTrials.gov Identifier, NCT01440842.


  • Open Access

    Physical Activity Energy Expenditure and Glucose Control in Pregnant Women With Type 1 Diabetes

    by Kavita Kumareswaran, Daniela Elleri, Janet M. Allen, Karen Caldwell, Kate Westgate, Soren Brage, Philippa Raymond-Barker, Marianna Nodale, Malgorzata E. Wilinska, Stephanie A. Amiel, et al.

    OBJECTIVE To describe activity patterns in pregnant women with type 1 diabetes and evaluate the impact of increased structured physical activity on glucose control. RESEARCH DESIGN AND METHODS Physical activity energy expenditure (PAEE) and glucose levels (continuous glucose monitoring) were measured in 10 pregnant women with type 1 diabetes (age 33.2 years, gestation 20 weeks, BMI 27.9 kg/m2, diabetes duration 16.6 years, HbA1c 6.5% [48 mmol/mol], insulin pump duration 2.4 years) during a day at home (free-living) and during a 24-h visit incorporating controlled diet and structured physical activity with light intensity activity (three 20-min self-paced walks) and moderate intensity activity (two 50-min sessions of brisk treadmill walking). PAEE was evaluated through individually calibrated combined heart rate and movement sensing. RESULTS Free-living PAEE was comparable to that under controlled study conditions (3.8 and 5.1 kcal/kg/day, P = 0.241), with women achieving near to the recommended 30 min of moderate physical activity (median 27 min [interquartile range 14–68]). During the free-living period, more time was spent in light activity (10.3 vs. 7.2 h, P = 0.005), with less sedentary time (13.0 vs. 14.9 h, P = 0.047) and less moderate activity (27 vs. 121 min, P = 0.022). The free-living 24-h mean glucose levels by continuous glucose monitoring were significantly higher (7.7 vs. 6.0 mmol/L, P = 0.028). The effect of controlled diet and exercise persisted overnight, with significantly less time spent hyperglycemic (19 vs. 0%, P = 0.028) and less glucose variability (glucose SD 1.3 vs. 0.7 mmol/L, P = 0.022). CONCLUSIONS A controlled diet and structured physical activity program may assist women with type 1 diabetes in achieving optimal glucose control during pregnancy.


  • Accuracy of Continuous Glucose Monitoring During Exercise in Type 1 Diabetes Pregnancy

    by Kavita Kumareswaran, Daniela Elleri, Janet M. Allen, Karen Caldwell, Marianna Nodale, Malgorzata E. Wilinska, Stephanie A. Amiel, Roman Hovorka, Helen R. Murphy

    Background: Performance of continuous glucose monitors (CGMs) may be lower when glucose levels are changing rapidly, such as occurs during physical activity. Our aim was to evaluate accuracy of a current-generation CGM during moderate-intensity exercise in type 1 diabetes (T1D) pregnancy. Subjects and Methods: As part of a study of 24-h closed-loop insulin delivery in 12 women with T1D (disease duration, 17.6 years; glycosylated hemoglobin, 6.4%) during pregnancy (gestation, 21 weeks), we evaluated the Freestyle Navigator ® sensor (Abbott Diabetes Care, Alameda, CA) during afternoon (15:00–18:00 h) and morning (09:30–12:30 h) exercise (55 min of brisk walking on a treadmill followed by a 2-h recovery), compared with sedentary conditions (18:00–09:00 h). Plasma (reference) glucose, measured at regular 15–30-min intervals with the YSI Ltd. (Fleet, United Kingdom) model YSI 2300 analyzer, was used to assess CGM performance. Results: Sensor accuracy, as indicated by the larger relative absolute difference (RAD) between paired sensor and reference glucose values, was lower during exercise compared with rest (median RAD, 11.8% vs. 18.4%; P P <0.001). Analysis by glucose range showed lower accuracy during hypoglycemia for both sedentary (median RAD, 24.4%) and exercise (median RAD, 32.1%) conditions. Using Clarke error grid analysis, 96% of CGM values were clinically safe under resting conditions compared with only 87% during exercise. Conclusions: Compared with sedentary conditions, accuracy of the Freestyle Navigator CGM was lower during moderate-intensity exercise in pregnant women with T1D. This difference was particularly marked in hypoglycemia and could not be solely explained by the glucose rate of change associated with physical activity.


  • Open Access

    Technological advances in pregnancy complicated by type 1 diabetes

    by Hr Murphy, D Elleri, K Kumareswaran, R Hovorka

  • Artificial pancreas: an emerging approach to treat Type 1 diabetes

    by Kavita Kumareswaran, Mark L Evans, Roman Hovorka

    Intensive insulin therapy aimed at achieving normal glucose levels significantly reduces the complications that are associated with diabetes but is also associated with an increased risk of low glucose levels (hypoglycemia). The growing use of continuous glucose monitors has stimulated the development of the artificial pancreas, a closed-loop insulin-delivery system aimed at restoring near-normal glucose levels while reducing the risk of hypoglycemia. The artificial pancreas comprises three components: a continuous glucose monitor, an insulin infusion pump and a control algorithm delivering insulin according to real-time glucose readings. In this article, we review closed-loop glucose control, including its components, development, testing and clinical application.