MBMargaret Baldwin

Margaret Baldwin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Margaret Baldwin has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Predicting the Type of Hearing Loss Using Click Auditory Brainstem Response in Babies Referred From Newborn Hearing Screening

    by Margaret Baldwin, Peter Watkin

    Objectives: This study examined the ability of click auditory brainstem response (ABR) undertaken below the age of 6 months (from expected date of delivery) to differentiate between conductive and sensorineural hearing loss (SNHL), using the latency of wave V measured 20 dB above threshold. Design: Subjects were recruited if they had an ABR threshold of ≥ 40 dB nHL and ≤ 70 dB nHL in one or both ears measured below the age of 6 months and they had also attended follow-up appointments for behavioral assessment of their hearing in which the type of hearing loss had been confirmed. Forty-five children (84 ears) with SNHL, 82 children (141 ears) with temporary conductive hearing loss (TCHL), and 5 children (10 ears) with permanent conductive hearing loss (PCHL) were recruited. The differences between mean wave V latencies measured 20 dB above ABR threshold were examined using the independent t-test for the groups of cases with SNHL, TCHL, and PCHL. Signal-detection theory was used to examine the relationship between sensitivity and specificity when the latency of wave V 20 dB above threshold was used to identify the presence of SNHL. Receiver operating characteristics were generated and the coordinates of the curve examined for the best compromise between sensitivity and false-alarm rate. The specificity, positive predictive value, and probability of missing a true case were determined for the most promising criteria. Results: There were significant differences between the two groups with SNHL and TCHL. The mean latency of wave V 20 dB above threshold was 1 msec shorter in those with SNHL compared with those with TCHL. There were significant differences between children with PCHL and SNHL but no difference between those with PCHL and TCHL. When a criterion of < 7.6 msec was chosen to predict the presence of SNHL the test sensitivity was 0.98, test specificity 0.71, and positive predictive value was 0.66. Nine out of 10 of those with a latency 20 dB above threshold of < 7.0 msec had an SNHL. Conclusions: The latency of wave V 20 dB above threshold measured using click ABR is a useful indicator of the type of hearing loss in babies referred from newborn hearing screening.


  • Predicting the Degree of Hearing Loss Using Click Auditory Brainstem Response in Babies Referred From Newborn Hearing Screening

    by Margaret Baldwin, Peter Watkin

    Objectives: The predictive ability of the auditory brainstem response (ABR) is an important factor governing the program sensitivity of neonatal hearing screens. The study examined the accuracy of the click-evoked auditory brainstem response (ck-ABR) when undertaken below the age of 6 months (from expected date of delivery) in predicting the pure-tone thresholds subsequently found to be present in children with a congenital permanent childhood hearing impairment. Design: Children with permanent childhood hearing impairment were ascertained from neonatal screening programs that have been subject to longitudinal evaluation. Ninety-two children who had ck-ABR recorded when below 6 months of age and repeatable ear specific pure-tone audiometry were recruited. Those with recognized temporary middle ear effusions at either test were excluded. The relationship between ABR and pure-tone thresholds was tested using the Pearson correlation coefficient with a linear regression model used to estimate pure-tone threshold (dependent variable) from ABR (independent variable). Correlation coefficients were obtained for pure-tone frequencies at octave intervals between 0.25 kHz and 4 kHz and at various frequency combinations. The difference between ABR and pure-tone threshold was analyzed. Those with a difference of greater than 20 dB were further examined. The ABR and pure-tone differences were also compared in babies born at term and prematurely. Results: Of the 92 children recruited to the study two children had a confirmed auditory neuropathy spectrum disorder (2%) and 10 (11%) had an audiometrically confirmed progressive hearing impairment. When these children were excluded, there was a high linear positive correlation (r = 0.90, SE = 14.3 dB) between the ABR and pure-tone thresholds averaged at 2 to 4 kHz. Although the correlation varied for different audiometric configurations, in all cases with a sloping hearing loss the correlation with their best frequency was weaker than the correlation at 2 to 4 kHz. For the total cohort the mean difference between ABR and pure-tone thresholds averaged at 2 to 4 kHz was 4.4 dB (SD = 19.29). The modal difference was 0 dB (58%) and 76 % had a difference of 20 dB or less. ABR underestimated the subsequently recorded pure-tone thresholds by more than 20 dB in 11 children and 10 of these children showed progression of their hearing loss measured by serial pure-tone audiometry. ABR overestimated the pure-tone thresholds by more than 20 dB in 15 children. Nine of these children (60%) had suffered a perinatal illness and the mean difference between the pure-tone and ABR thresholds was significantly greater in those born at p < 0.001). Conclusions: There is a high positive linear correlation between ck-ABR and pure-tone average thresholds at 2 to 4 kHz. However, the predictive value of ABR is reduced in certain neonatal groups. The cause for this is discussed as are the implications for undertaking a test battery at this age to improve the predictive accuracy.


  • Auditory steady-state responses in babies with normal hearing and with temporary conductive hearing loss

    by Peter Watkin, Dani Tomlin, Margaret Baldwin

    Objectives: To investigate whether test age and middle ear dysfunction had a significant effect on the variability of Auditory Steady-State Response (ASSR) thresholds when this test was undertaken on referrals from the newborn hearing screen. Methods: ASSR thresholds were measured at octave intervals from 500 Hz to 4000 Hz. They were recorded in 389 ears with normal hearing and middle ear function, and in a further 189 ears with temporary middle ear dysfunction. The modal corrected age at which the tests were undertaken was four weeks, with a minimum of one week and maximum corrected age of 26 weeks. Results: The mean ASSR thresholds of those with normal hearing were 47dB HL at 500 Hz, 36dB HL at 1000 Hz, and 34dB HL at both 2000 Hz and 4000 Hz. Standard deviations (SDs) from the mean ranged from 7.7 to 9.9dB. For those with middle ear dysfunction the mean ASSR thresholds were significantly greater at each frequency, with thresholds of 65dB HL at 500 Hz, 55dB HL at 1000 Hz, 53dB HL at 2000 Hz and 52dB HL at 4000 Hz. SDs from the mean ranged from 12.9 to 17.9dB. Mean thresholds decreased at all frequencies during the first half of infancy. In those with normal middle ear function the decrease was only 2dB at 500 Hz, but was over 5dB at both 1000 and 2000 Hz and was 4dB at 4000 Hz. A similar decrease was seen over the same period in those with middle ear dysfunction. Conclusions: ASSR thresholds measured in early infancy are affected by both test age and the presence of middle ear dysfunction and are more variable than ABR thresholds measured in babies with normal hearing or a mild conductive loss. A flexible test battery for gaining frequency specific information is therefore required at this age.