- Aldo Milano
Division of Cardiovascular Surgery, Università degli Studi di Verona, Verona, Italy
3 shared publications - Giuseppe Faggian
Department of Surgery, Dentistry, Pediatrics, and Gynecology, The University of Verona, Italy (R.T., V.B., C.L., M.T., G.F., G.B.L.).
3 shared publications - Francesco Onorati
Center for Medical Sciences (CISMed), University of Trento, Trento, Italy
2 shared publications Maddalena Tessari
Division of Cardiac Surgery, Department of Surgery, University of Verona Medical School, Verona, Italy
2 shared publicationsTiziano Menon
Division of Cardiac Surgery, Department of Surgery, University of Verona Medical School, Verona, Italy
2 shared publicationsAlessandro Mazzucco
Division of Cardiac Surgery University of Verona Verona Italy
1 shared publication
Latest Publications
- Open Access
- 16 April 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (2) , 291-298
Pulsatile cardiopulmonary bypass and renal function in elderly patients undergoing aortic valve surgery†
To evaluate if pulsatile cardiopulmonary bypass (CPB) has any protective influence on renal function in elderly patients undergoing aortic valve replacement (AVR). Forty-six patients (≥75 years old) with aortic valve stenosis underwent AVR with either pulsatile perfusion (PP) or non-pulsatile perfusion (NP) during CPB. Haemodynamic efficacy of the blood pump during either type of perfusion was described in terms of the energy equivalent pressure and the surplus haemodynamic energy. Urine samples were collected before surgery, at sternum closure, and at 2 and 18 h of intensive care unit stay to detect acute kidney injury markers. Perioperative urine levels of N-acetyl-β-d-glucosaminidase (NAG), kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin (NGAL) were assessed together with plasma creatinine, creatinine clearance (CCr) and 24-h haemodynamic monitoring. Normally distributed continuous variables were described as mean ± standard deviation and non-normally distributed data were presented as the median [25th–75th percentiles]. PP was characterized by a significantly higher amount of surplus haemodynamic energy transferred to the patients (P < 0.001), with lower mean systemic vascular resistance during CPB (P = 0.020) and during 18 h postoperatively (group-P = 0.018). No difference was found between pre- and postoperative CCr in the PP group (71 ± 23 vs 60 ± 35 ml/min, P = 0.27), while its statistically significant perioperative decrement was observed in the NP group (67 ± 24 vs 45 ± 15 ml/min, P < 0.001). The PP group showed significantly lower urinary levels of NAG at 18 h postoperatively (P = 0.008), and NGAL at sternum closure (P = 0.010), 2 h (P < 0.001) and 18 h (P = 0.015) postoperatively. Short-term PP in elderly patients showed higher safety for renal physiology than NP, resulting in better maintenance of glomerular filtration and lower renal tissue injury.
- 16 April 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (2) , 291-298
Open AccessPulsatile cardiopulmonary bypass and renal function in elderly patients undergoing aortic valve surgery†
To evaluate if pulsatile cardiopulmonary bypass (CPB) has any protective influence on renal function in elderly patients undergoing aortic valve replacement (AVR). Forty-six patients (≥75 years old) with aortic valve stenosis underwent AVR with either pulsatile perfusion (PP) or non-pulsatile perfusion (NP) during CPB. Haemodynamic efficacy of the blood pump during either type of perfusion was described in terms of the energy equivalent pressure and the surplus haemodynamic energy. Urine samples were collected before surgery, at sternum closure, and at 2 and 18 h of intensive care unit stay to detect acute kidney injury markers. Perioperative urine levels of N-acetyl-β-d-glucosaminidase (NAG), kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin (NGAL) were assessed together with plasma creatinine, creatinine clearance (CCr) and 24-h haemodynamic monitoring. Normally distributed continuous variables were described as mean ± standard deviation and non-normally distributed data were presented as the median [25th–75th percentiles]. PP was characterized by a significantly higher amount of surplus haemodynamic energy transferred to the patients (P < 0.001), with lower mean systemic vascular resistance during CPB (P = 0.020) and during 18 h postoperatively (group-P = 0.018). No difference was found between pre- and postoperative CCr in the PP group (71 ± 23 vs 60 ± 35 ml/min, P = 0.27), while its statistically significant perioperative decrement was observed in the NP group (67 ± 24 vs 45 ± 15 ml/min, P < 0.001). The PP group showed significantly lower urinary levels of NAG at 18 h postoperatively (P = 0.008), and NGAL at sternum closure (P = 0.010), 2 h (P < 0.001) and 18 h (P = 0.015) postoperatively. Short-term PP in elderly patients showed higher safety for renal physiology than NP, resulting in better maintenance of glomerular filtration and lower renal tissue injury.
- 13 March 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (4) , 357-367
Gaseous Micro‐Emboli Activity During Cardiopulmonary Bypass in Adults: Pulsatile Flow Versus Nonpulsatile Flow
Cardiopulmonary bypass (CPB) has a risk of cerebral injury, with an important role of gaseous micro‐emboli (GME) coming from the CPB circuit. Pulsatile perfusion is supposed to perform specific conditions for supplementary GME activity. We aimed to determine whether pulsatile CPB augments production and delivery of GME and evaluate the role of different events in GME activity during either type of perfusion. Twenty‐four patients who underwent on‐pump coronary artery bypass grafting surgery at the University of Verona were divided equally into two groups—pulsatile perfusion (PP) group and nonpulsatile perfusion (NP) group. The circuit included a JostraHL‐20 roller pump set in pulsatile or nonpulsatile mode, an open Sorin Synthesis membrane oxygenator with integrated screen‐type arterial filter, and phosphorylcholine‐coated tubes. Hemodynamic flow evaluation was performed in terms of energy equivalent pressure and surplus hemodynamic energy (SHE). GME were counted by means of a GAMPT BCC200 bubble counter (GAMPT, Zappendorf, Germany) with two probes placed at postpump and postarterial filter positions. Results were evaluated in terms of GME number, GME volume, number of over‐ranged GME from both probes, and series of filtering indexes. In PP mode, the pump produced and delivered along the circuit significantly higher amounts of SHE than in NP mode. At the venous postpump site, GME number was significantly higher during PP but no difference was found in terms of GME volume or number of over‐ranged bubbles. No significant difference in GME number, GME volume, or number of over‐ranges was found at the postarterial filter site. Filtering indexes were similar between the two groups. Neither type of perfusion was shown to contribute to excessive GME production during the most important perfusionist manipulation. Pulsatility leads to GME increment by splitting and size diminishing of the existing bubbles but not by additional gas production. PP augmented GME number at the venous postpump site, while mean volume remained comparable with NP. Sorin Synthesis oxygenator showed high efficacy in GME removal during either type of perfusion. Supplementary GME production and delivery during typical perfusionist manipulations did not depend on perfusion type.
- 13 March 2013
- Published by Wiley in Artificial Organs
- Vol. 37 (4) , 357-367
Gaseous Micro‐Emboli Activity During Cardiopulmonary Bypass in Adults: Pulsatile Flow Versus Nonpulsatile Flow
Cardiopulmonary bypass (CPB) has a risk of cerebral injury, with an important role of gaseous micro‐emboli (GME) coming from the CPB circuit. Pulsatile perfusion is supposed to perform specific conditions for supplementary GME activity. We aimed to determine whether pulsatile CPB augments production and delivery of GME and evaluate the role of different events in GME activity during either type of perfusion. Twenty‐four patients who underwent on‐pump coronary artery bypass grafting surgery at the University of Verona were divided equally into two groups—pulsatile perfusion (PP) group and nonpulsatile perfusion (NP) group. The circuit included a JostraHL‐20 roller pump set in pulsatile or nonpulsatile mode, an open Sorin Synthesis membrane oxygenator with integrated screen‐type arterial filter, and phosphorylcholine‐coated tubes. Hemodynamic flow evaluation was performed in terms of energy equivalent pressure and surplus hemodynamic energy (SHE). GME were counted by means of a GAMPT BCC200 bubble counter (GAMPT, Zappendorf, Germany) with two probes placed at postpump and postarterial filter positions. Results were evaluated in terms of GME number, GME volume, number of over‐ranged GME from both probes, and series of filtering indexes. In PP mode, the pump produced and delivered along the circuit significantly higher amounts of SHE than in NP mode. At the venous postpump site, GME number was significantly higher during PP but no difference was found in terms of GME volume or number of over‐ranged bubbles. No significant difference in GME number, GME volume, or number of over‐ranges was found at the postarterial filter site. Filtering indexes were similar between the two groups. Neither type of perfusion was shown to contribute to excessive GME production during the most important perfusionist manipulation. Pulsatility leads to GME increment by splitting and size diminishing of the existing bubbles but not by additional gas production. PP augmented GME number at the venous postpump site, while mean volume remained comparable with NP. Sorin Synthesis oxygenator showed high efficacy in GME removal during either type of perfusion. Supplementary GME production and delivery during typical perfusionist manipulations did not depend on perfusion type.
- 6 January 2012
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 35 (7) , 481-488
The Sorin Freedom Stentless Pericardial Valve: Clinical and Echocardiographic Performance at 10 years
Objective: The Sorin Pericarbon Freedom (SPF) is a stentless valve made of pericardium clinically available in 1990. We report the clinical and hemodynamic performance of the SPF at 10 years. Methods: From April 2000 to December 2005, 85 patients with a mean age of 75 ± 6 years (range 57–86), underwent aortic valve replacement (AVR) with an SPF. Mean left ventricular ejection fraction was 58 ± 10% (range 29–86%) and mean peak transvalvular gradient (PG) 86 ± 24 mm Hg. Clinical evaluation was performed at 3, 6, 12 months, and yearly thereafter. Results: There were 2 operative deaths (2.4%). Follow-up ranged from 2 to 135 months (mean 78 ± 32 months) and was 99% complete. There were 35 late deaths, 7 of which were valve-related, with an actuarial survival of 45 ± 8% at 10 years. Structural SPF deterioration occurred in 2 patients, with an actuarial freedom of 96 ± 3%. A total of 4 patients were re-operated, 2 because of structural deterioration, 1 because of endocarditis, and 1 because of sinotubular junction dilatation; freedom from reoperation was 93 ± 4% at 10 years. At last clinical control, 41 patients (89%) were in NYHA class I or II. Mean SPF effective orifice area varied from 1.55 ± 0.66 cm2 for size 21 mm to 2.33 ± 0.86 cm2 for size 27 mm; PG varied from 19 ± 10 mm Hg for size 21 mm to 11 ± 6 mm Hg for size 27 mm. Left ventricular mass index decreased from 213 ± 51 gm/m2 to 157 ± 436 gm/m2 (p<0.001). Conclusions: The SPF has demonstrated overall good results in terms of valve durability and freedom from valve-related complications up to 10 years, with excellent hemodynamic performance.
- 6 January 2012
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 35 (7) , 481-488
The Sorin Freedom Stentless Pericardial Valve: Clinical and Echocardiographic Performance at 10 years
Objective: The Sorin Pericarbon Freedom (SPF) is a stentless valve made of pericardium clinically available in 1990. We report the clinical and hemodynamic performance of the SPF at 10 years. Methods: From April 2000 to December 2005, 85 patients with a mean age of 75 ± 6 years (range 57–86), underwent aortic valve replacement (AVR) with an SPF. Mean left ventricular ejection fraction was 58 ± 10% (range 29–86%) and mean peak transvalvular gradient (PG) 86 ± 24 mm Hg. Clinical evaluation was performed at 3, 6, 12 months, and yearly thereafter. Results: There were 2 operative deaths (2.4%). Follow-up ranged from 2 to 135 months (mean 78 ± 32 months) and was 99% complete. There were 35 late deaths, 7 of which were valve-related, with an actuarial survival of 45 ± 8% at 10 years. Structural SPF deterioration occurred in 2 patients, with an actuarial freedom of 96 ± 3%. A total of 4 patients were re-operated, 2 because of structural deterioration, 1 because of endocarditis, and 1 because of sinotubular junction dilatation; freedom from reoperation was 93 ± 4% at 10 years. At last clinical control, 41 patients (89%) were in NYHA class I or II. Mean SPF effective orifice area varied from 1.55 ± 0.66 cm2 for size 21 mm to 2.33 ± 0.86 cm2 for size 27 mm; PG varied from 19 ± 10 mm Hg for size 21 mm to 11 ± 6 mm Hg for size 27 mm. Left ventricular mass index decreased from 213 ± 51 gm/m2 to 157 ± 436 gm/m2 (p<0.001). Conclusions: The SPF has demonstrated overall good results in terms of valve durability and freedom from valve-related complications up to 10 years, with excellent hemodynamic performance.