Mehrdad Moallem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mehrdad Moallem has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
R.V. Patel
5 shared publications- Rajni V. Patel
University of Western Ontario
5 shared publications - Basem Yousef
Department of Electrical & Computer Engineering, University of Western Ontario, London, Ontario, Canada. N6A5B9
2 shared publications - Gerry Moschopoulos
University of Western Ontario, Department of Electrical and Computer Engineering, Thompson Engineering Building, London, Ontario, Canada, N6A 5B9
2 shared publications - H. Bassan
Electrical and Computer Engineering Department, The University of Western Ontario, London, Ontario, Canada, N6A5B9
2 shared publications - Roohollah Fadaeinedjad
University of Western Ontario, London, ON, Canada
2 shared publications
Latest Publications
- 1 January 2009
- Published by ACTA Press in International Journal of Robotics and Automation
- Vol. 24 (1) , 10-19
A FEEDBACK SCHEDULING FRAMEWORK FOR REAL-TIME ROBOTIC ASSEMBLY SYSTEMS
- 1 January 2009
- Published by ACTA Press in International Journal of Robotics and Automation
- Vol. 24 (1) , 10-19
A FEEDBACK SCHEDULING FRAMEWORK FOR REAL-TIME ROBOTIC ASSEMBLY SYSTEMS
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 88-93
Nonlinear Position Control of Antagonistic Shape Memory Alloy Actuators
This paper presents a control scheme for angular position control of a rotary load using shape memory alloy (SMA) actuators in an antagonistic configuration. Hysteresis and significant nonlinearities in the stress-strain-temperature characteristics hinder effective utilization of SMA actuator. By considering the nonlinear behavior and thermal characteristics of SMA, a force control scheme based on partial feedback linearization and sliding surfaces is developed in this paper to regulate the torque applied by a differential SMA actuator pair. A position controller is then used to generate a desired torque which serves as a reference input for the force tracking controller. The controller is based on sliding surfaces and does not depend on characteristics of SMA. Thus an approximate model of SMA characteristics is sufficient. Experimental studies indicate that the proposed controller performs well in terms of achieving small tracking errors.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 88-93
Nonlinear Position Control of Antagonistic Shape Memory Alloy Actuators
This paper presents a control scheme for angular position control of a rotary load using shape memory alloy (SMA) actuators in an antagonistic configuration. Hysteresis and significant nonlinearities in the stress-strain-temperature characteristics hinder effective utilization of SMA actuator. By considering the nonlinear behavior and thermal characteristics of SMA, a force control scheme based on partial feedback linearization and sliding surfaces is developed in this paper to regulate the torque applied by a differential SMA actuator pair. A position controller is then used to generate a desired torque which serves as a reference input for the force tracking controller. The controller is based on sliding surfaces and does not depend on characteristics of SMA. Thus an approximate model of SMA characteristics is sufficient. Experimental studies indicate that the proposed controller performs well in terms of achieving small tracking errors.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-8
Voltage Sag Impact on Wind Turbine Tower Vibration
In order to study the voltage sag impact on mechanical vibration of wind turbine structure a detailed model that considers all three electrical, mechanical and aerodynamic aspects of the wind turbine must be considered. A drawback of many works in the area of wind turbine simulation is that either a very simple mechanical model is used with a detailed electrical model or vice versa. Hence the effects of interactions between electrical and mechanical components are not accurately taken into account. In this paper, three simulation programs - TurbSim, FAST, and Simulink - are used to model the wind, mechanical and electrical parts of a wind turbine, and its controllers in detail. Simulation results obtained from the model are used to observe the interaction of all three factors affecting the operation of a wind turbine system. Especially, the voltage sag impact on tower vibration is investigated, considering different power system characteristics (i.e. short circuit level (SCL) and X/R ratio), and wind turbine operating conditions.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-8
Voltage Sag Impact on Wind Turbine Tower Vibration
In order to study the voltage sag impact on mechanical vibration of wind turbine structure a detailed model that considers all three electrical, mechanical and aerodynamic aspects of the wind turbine must be considered. A drawback of many works in the area of wind turbine simulation is that either a very simple mechanical model is used with a detailed electrical model or vice versa. Hence the effects of interactions between electrical and mechanical components are not accurately taken into account. In this paper, three simulation programs - TurbSim, FAST, and Simulink - are used to model the wind, mechanical and electrical parts of a wind turbine, and its controllers in detail. Simulation results obtained from the model are used to observe the interaction of all three factors affecting the operation of a wind turbine system. Especially, the voltage sag impact on tower vibration is investigated, considering different power system characteristics (i.e. short circuit level (SCL) and X/R ratio), and wind turbine operating conditions.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 232-237
An Ultrasound Probe Holder for Image-Guided Robot-Assisted Prostate Brachytherapy
An ultrasound probe holder is designed for use in the prostate brachytherapy procedure. The holder comprises a passive-jointed stabilizer that can be used to position, manipulate and lock in place the ultrasound probe, and a tracker mechanism to provide the position and orientation of the probe in 3D space. The information obtained from the integrated stabilizer-tracker mechanism can be utilized in image-guided robot-assisted prostate brachytherapy procedures. Performance tests show that the tracker assembly can acquire the position and orientation of the ultrasound probe with an average displacement accuracy of 0.66 mm and roll, pitch and yaw angular accuracies of 0.24deg, 0.38deg and 0.19deg, respectively.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 232-237
An Ultrasound Probe Holder for Image-Guided Robot-Assisted Prostate Brachytherapy
An ultrasound probe holder is designed for use in the prostate brachytherapy procedure. The holder comprises a passive-jointed stabilizer that can be used to position, manipulate and lock in place the ultrasound probe, and a tracker mechanism to provide the position and orientation of the probe in 3D space. The information obtained from the integrated stabilizer-tracker mechanism can be utilized in image-guided robot-assisted prostate brachytherapy procedures. Performance tests show that the tracker assembly can acquire the position and orientation of the ultrasound probe with an average displacement accuracy of 0.66 mm and roll, pitch and yaw angular accuracies of 0.24deg, 0.38deg and 0.19deg, respectively.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 617-622
A Novel Manipulator for 3D Ultrasound Guided Percutaneous Needle Insertion
The prostate is a small exocrine gland in men responsible for production of the liquid component of the seminal fluid. In North America, prostate cancer accounts for over 300,000 new cases and 40,000 deaths each year and it is the second leading cause of cancer death in men. Low-dose Rate (LDR) brachytherapy is gaining interest as a viable treatment option for prostate cancer due to its low side effects and high benefits. The present manual approach for brachytherapy needle insertion and the inherent flexibility of the needles make it extremely difficult to achieve accurate and consistent dosimetry. In this paper, we present a new 5 degrees-of-freedom (DOF) manipulator capable of performing percutaneous needle insertion. The manipulator can perform orientation, insertion and rotation of the needle and linear motion of the plunger to drop radioactive seeds at targeted locations. The manipulator is an integral part of a system utilizing a mechanically rotated side-fire transducer to create 3D ultrasound images of the organ and utilizing 3D SLICER software to visualize those images. Experiments conducted in agar phantoms reveal an average RMS targeting error of 1.45mm at an average insertion depth of 75.78mm proving the feasibility and efficacy of the proposed robotic system for percutaneous needle insertion.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 617-622
A Novel Manipulator for 3D Ultrasound Guided Percutaneous Needle Insertion
The prostate is a small exocrine gland in men responsible for production of the liquid component of the seminal fluid. In North America, prostate cancer accounts for over 300,000 new cases and 40,000 deaths each year and it is the second leading cause of cancer death in men. Low-dose Rate (LDR) brachytherapy is gaining interest as a viable treatment option for prostate cancer due to its low side effects and high benefits. The present manual approach for brachytherapy needle insertion and the inherent flexibility of the needles make it extremely difficult to achieve accurate and consistent dosimetry. In this paper, we present a new 5 degrees-of-freedom (DOF) manipulator capable of performing percutaneous needle insertion. The manipulator can perform orientation, insertion and rotation of the needle and linear motion of the plunger to drop radioactive seeds at targeted locations. The manipulator is an integral part of a system utilizing a mechanically rotated side-fire transducer to create 3D ultrasound images of the organ and utilizing 3D SLICER software to visualize those images. Experiments conducted in agar phantoms reveal an average RMS targeting error of 1.45mm at an average insertion depth of 75.78mm proving the feasibility and efficacy of the proposed robotic system for percutaneous needle insertion.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (1062922X) , 530-535
A Macro-Robot Manipulator for Medical Applications
An actuated robot arm is designed for use as a macro manipulator that can carry, appropriately orient, precisely position and firmly "lock" in position different types of micro robots and surgical tools necessary for applications in minimally invasive therapy. The sophisticated configuration and joint structure of the arm enable it to perform and interact efficiently with the constrained and limited workspace of surgical environments. The normally locked braking system and the simple quick release joint enhance the safety features of the robot for emergencies and power shutdown. With a simple manipulation protocol, the surgeon can use the robot without undergoing any training. Robot workspace analysis indicates that all singularities are outside the operating work envelope. A performance analysis shows that the robot operates with an average displacement accuracy of 0.58 mm and a roll, pitch and yaw angular accuracies of 0.26deg, 0.26deg and 0.38deg respectively.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (1062922X) , 530-535
A Macro-Robot Manipulator for Medical Applications
An actuated robot arm is designed for use as a macro manipulator that can carry, appropriately orient, precisely position and firmly "lock" in position different types of micro robots and surgical tools necessary for applications in minimally invasive therapy. The sophisticated configuration and joint structure of the arm enable it to perform and interact efficiently with the constrained and limited workspace of surgical environments. The normally locked braking system and the simple quick release joint enhance the safety features of the robot for emergencies and power shutdown. With a simple manipulation protocol, the surgeon can use the robot without undergoing any training. Robot workspace analysis indicates that all singularities are outside the operating work envelope. A performance analysis shows that the robot operates with an average displacement accuracy of 0.58 mm and a roll, pitch and yaw angular accuracies of 0.26deg, 0.26deg and 0.38deg respectively.
- 21 September 2006
- Published by Springer Nature in Journal of Intelligent & Robotic Systems
- Vol. 47 (2) , 101-124
A Fuzzy–Braitenberg Navigation Strategy for Differential Drive Mobile Robots
- 21 September 2006
- Published by Springer Nature in Journal of Intelligent & Robotic Systems
- Vol. 47 (2) , 101-124
A Fuzzy–Braitenberg Navigation Strategy for Differential Drive Mobile Robots
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 587-591
An Environment for Programming and Control of Multi-Robot Manipulators
This paper discusses the development of an open architecture multi-robot system. The environment consists of five serial-link robot manipulators in the ECE robotics laboratory at the University of Western Ontario, Canada. The robots are operated under their original controllers which are connected together through a network of supervisory computers. A preemptive multi-tasking real time operating system (RTOS) running on these computers is used to perform supervisory and cooperative tasks involving multiple robots. The software environment allows for controlling the motion of one or more robots and their interaction with other devices. Development of modular components is discussed in this paper along with typical laboratory procedures with a link to a short video demonstration for a multi-robot object handling task. The environment is used to train undergraduate and graduate students on how to develop software for various robotic applications, including scheduling techniques, cooperative manipulation, collision avoidance, and emerging robotic applications
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 587-591
An Environment for Programming and Control of Multi-Robot Manipulators
This paper discusses the development of an open architecture multi-robot system. The environment consists of five serial-link robot manipulators in the ECE robotics laboratory at the University of Western Ontario, Canada. The robots are operated under their original controllers which are connected together through a network of supervisory computers. A preemptive multi-tasking real time operating system (RTOS) running on these computers is used to perform supervisory and cooperative tasks involving multiple robots. The software environment allows for controlling the motion of one or more robots and their interaction with other devices. Development of modular components is discussed in this paper along with typical laboratory procedures with a link to a short video demonstration for a multi-robot object handling task. The environment is used to train undergraduate and graduate students on how to develop software for various robotic applications, including scheduling techniques, cooperative manipulation, collision avoidance, and emerging robotic applications
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 575-580
Force Control of a Single-Link Flexible Arm
A force control scheme is proposed in this paper for flexible manipulators based on a concentrated parameter mechanical model. This model is then used to develop a simple feedback control law for the coupling torque between the motor and the flexible arm. This control offers a good regulation of the contact force exerted by the flexible arm on the object, measuring only the coupling torque without the need to measure the contact force and the angle of the motor. The control law is described as a gain integral controller. Another outer control loop based on a linear quadratic regulator (LQR) is added to improve the performance of the previous control. Also a collision detection algorithm is described for dealing with the force control problem
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 575-580
Force Control of a Single-Link Flexible Arm
A force control scheme is proposed in this paper for flexible manipulators based on a concentrated parameter mechanical model. This model is then used to develop a simple feedback control law for the coupling torque between the motor and the flexible arm. This control offers a good regulation of the contact force exerted by the flexible arm on the object, measuring only the coupling torque without the need to measure the contact force and the angle of the motor. The control law is described as a gain integral controller. Another outer control loop based on a linear quadratic regulator (LQR) is added to improve the performance of the previous control. Also a collision detection algorithm is described for dealing with the force control problem
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (21635137) , 2648-2653
Simulation of a Wind Turbine with Doubly-Fed Induction Machine Using FAST and Simulink
In order to fully study the electrical, mechanical and aerodynamic aspects of a wind turbine with a doubly-fed induction machine (DFIM), a detailed model that considers all these aspects must be used. In general, however, detailed electrical models are combined with very simple mechanical and aerodynamic models or vice versa, so that the effects of interactions between all three aspects are neglected. In the paper, three simulation programs - TurbSim, FAST, and Simulink - are used to model the wind, mechanical and electrical parts of a wind turbine and its controllers in detail. Simulation results obtained from the model are used to observe the interaction of all three aspects of a wind turbine system
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (21635137) , 2648-2653
Simulation of a Wind Turbine with Doubly-Fed Induction Machine Using FAST and Simulink
In order to fully study the electrical, mechanical and aerodynamic aspects of a wind turbine with a doubly-fed induction machine (DFIM), a detailed model that considers all these aspects must be used. In general, however, detailed electrical models are combined with very simple mechanical and aerodynamic models or vice versa, so that the effects of interactions between all three aspects are neglected. In the paper, three simulation programs - TurbSim, FAST, and Simulink - are used to model the wind, mechanical and electrical parts of a wind turbine and its controllers in detail. Simulation results obtained from the model are used to observe the interaction of all three aspects of a wind turbine system