Beatrice M. Stefanescu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Beatrice M. Stefanescu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- James Christopher Slaughter
Department of Biostatistics, Vanderbilt University Medical Center, Nashville, Tennessee, USA
2 shared publications - Avinash K. Shetty
Department of Pediatrics and Office of Global Health, Wake Forest University School of Medicine, Winston-Salem, North Carolina
1 shared publication Caroline Hétu
1 shared publicationFran Haury
Clinical Affairs, Respiratory and Monitoring Solutions, Covidien, Boulder, Colorado
1 shared publicationJ C Slaughter
1 shared publicationN Frewan
1 shared publication
Latest Publications
- Open Access
- 1 January 2016
- Published by SAGE Publications in Respiratory Care
- Vol. 61 (1) , 85-89
Improved Filtering of Pulse Oximeter Monitoring Alarms in the Neonatal ICU: Bedside Significance
BACKGROUND: The OxiMax N-600x containing SatSeconds alarm management software was designed to assist clinicians in discriminating nuisance alarms from those that are clinically relevant. Instead of sounding an alarm the moment the oxygen saturation reading violates the upper or lower limit settings, a magnitude and duration of tolerance can be set. The primary objective was to study the proportion of nuisance alarms relative to the proportion of clinically relevant alarms being filtered under 4 different SatSeconds alarm settings (ie, 10, 25, 50, and 100) in the neonatal intensive care environment. METHODS: This is an observational prospective study of 50 infants cared for in 3 large neonatal ICUs. Infants were monitored for 4 continuous h each by a study observer with the study monitor, in addition to standard multiparameter monitors. The performance of the SatSeconds alarm was compared with nursing intervention. RESULTS: The area under the receiver operating characteristic curve (95% CI) for SatSeconds alarm settings when compared with nursing intervention were as follows: 0.61 (0.57–0.66) when the SatSeconds alarm setting was off, 0.63 (0.59–0.68) for the 10 SatSeconds alarm setting, 0.64 (0.59–0.69) for the 25 SatSeconds alarm setting, 0.64 (0.59–0.69) for the 50 SatSeconds alarm setting, and 0.63 (0.58–0.68) for the 100 SatSeconds alarm setting, respectively. CONCLUSIONS: The SatSeconds feature of the OxiMax N-600x pulse oximeter reduced some nuisance alarms; however, its specificity to nurse-identified desaturation events does not significantly improve with lengthening SatSeconds alarm settings.
- 1 January 2016
- Published by SAGE Publications in Respiratory Care
- Vol. 61 (1) , 85-89
Open AccessImproved Filtering of Pulse Oximeter Monitoring Alarms in the Neonatal ICU: Bedside Significance
BACKGROUND: The OxiMax N-600x containing SatSeconds alarm management software was designed to assist clinicians in discriminating nuisance alarms from those that are clinically relevant. Instead of sounding an alarm the moment the oxygen saturation reading violates the upper or lower limit settings, a magnitude and duration of tolerance can be set. The primary objective was to study the proportion of nuisance alarms relative to the proportion of clinically relevant alarms being filtered under 4 different SatSeconds alarm settings (ie, 10, 25, 50, and 100) in the neonatal intensive care environment. METHODS: This is an observational prospective study of 50 infants cared for in 3 large neonatal ICUs. Infants were monitored for 4 continuous h each by a study observer with the study monitor, in addition to standard multiparameter monitors. The performance of the SatSeconds alarm was compared with nursing intervention. RESULTS: The area under the receiver operating characteristic curve (95% CI) for SatSeconds alarm settings when compared with nursing intervention were as follows: 0.61 (0.57–0.66) when the SatSeconds alarm setting was off, 0.63 (0.59–0.68) for the 10 SatSeconds alarm setting, 0.64 (0.59–0.69) for the 25 SatSeconds alarm setting, 0.64 (0.59–0.69) for the 50 SatSeconds alarm setting, and 0.63 (0.58–0.68) for the 100 SatSeconds alarm setting, respectively. CONCLUSIONS: The SatSeconds feature of the OxiMax N-600x pulse oximeter reduced some nuisance alarms; however, its specificity to nurse-identified desaturation events does not significantly improve with lengthening SatSeconds alarm settings.
- 4 December 2015
- Published by Georg Thieme Verlag KG in Neonatologie Scan
- Vol. 04 (04) , 295
Volumengarantierte Beatmung reduziert Mortalität und neurologische Defizite
Verglichen mit der PCV hatte die VGPSV bessere Kurzzeitergebnisse. Pulmonale Komplikationen traten seltener auf und die Mortalität war geringer. Langfristig bestand kein Überlebensvorteil. Die neurologische Entwicklung verlief tendenziell günstiger.
- 4 December 2015
- Published by Georg Thieme Verlag KG in Neonatologie Scan
- Vol. 04 (04) , 295
Volumengarantierte Beatmung reduziert Mortalität und neurologische Defizite
Verglichen mit der PCV hatte die VGPSV bessere Kurzzeitergebnisse. Pulmonale Komplikationen traten seltener auf und die Mortalität war geringer. Langfristig bestand kein Überlebensvorteil. Die neurologische Entwicklung verlief tendenziell günstiger.
- 1 July 2013
- Published by Elsevier in Contemporary Clinical Trials
- Vol. 35 (2) , 33-39
A pilot study of Biotene OralBalance® gel for oral care in mechanically ventilated preterm neonates
- 1 July 2013
- Published by Elsevier in Contemporary Clinical Trials
- Vol. 35 (2) , 33-39
A pilot study of Biotene OralBalance® gel for oral care in mechanically ventilated preterm neonates