Andrew B. Slate
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andrew B. Slate has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Thomas B. Whitaker
U.S. Department of Agriculture, Agricultural Research Service, Box 7625, North Carolina State University, Raleigh, NC 27695-7625
9 shared publications Francis G Giesbrecht
4 shared publicationsEliene A Santos
Ministério da Agricultura, Pecuária e Abastecimento, Laboratório de Controle de Qualidade e Segurança Alimentar/LAV-MG, Av. Raja Gabaglia, 245, Cidade Jardim, 30380-090, Belo Horizonte,Minas Gerais, Brazil
2 shared publicationsFrancisco B Lima
Ministério da Agricultura, Pecuria e Abastecimento, Departamento do Café, Av. do Café, 543, 86038-000, Londrina, Paraná, Brazil
2 shared publicationsJ Michael Hurley
2 shared publicationsEugenia A Vargas
Ministério da Agricultura, Pecuária e Abastecimento, Laboratório de Controle de Qualidade e Segurança Alimentar/LAV-MG, Av. Raja Gabaglia, 245, Cidade Jardim, 30380-090, Belo Horizonte, Minas Gerais, Brazil
1 shared publication
Latest Publications
- 1 January 2012
- Published by American Peanut Research and Education Society in Peanut Science
- Vol. 39 (1) , 69-81
Comparing the USDA/AMS Subsampling Mill to a Vertical Cutter Mixer Type Mill Used to Comminute Shelled Peanut Samples for Aflatoxin Analysis1
The US peanut industry can use up to three 21.8 kg samples per lot to determine if shelled peanut lots are acceptable or unacceptable due to aflatoxin content. If a lot is accepted by the first 21.8 kg sample (1AB≤8 ng/g) prepared with the USDA/AMS Subsampling mill (DM), then some peanut buyers request that the sheller prepare the second sample (2AB) and in some cases the 3AB sample (called special samples in the trade) with a vertical cutter mixer (VCM) type mill. These requests to specifically use the VCM instead of the DM to prepare official (1AB) and special (2AB or 3AB) samples is based in part on a perception that analytical results associated with a test portion taken from the 21.8 kg sample comminuted with a DM does not detect the full magnitude of aflatoxin in the 21.8 kg sample and that negative aflatoxin certificates (lot acceptance) are more likely to occur when samples are prepared with a DM than a VCM. Analysis of aflatoxin test results from two shellers along with Monte Carlo simulation indicate that differences between the 1AB and special sample test results are due to the use of a cut-off limit (≤ 8 ng/g associated with the 1AB) requested by the buyer as part of the acceptance criteria and not due to any bias associated with the DM. Operating characteristic curves were used to demonstrate that the performance of the USDA/AMS aflatoxin sampling plan is about the same regardless of the use of a DM or a VCM for sample preparation. The performances are similar because the DM, with an 1100 g test portion, account for only 8% of the total variability of the aflatoxin test procedure (sampling and analysis account for about 92%). A sampling plan that requires two 21.8 kg samples to test less than a limit, regardless of mill used to prepare the two samples, has a very low risk of accepting bad lots above the FDA limit of 20 ng/g, but has a very high risk of rejecting good lots, which makes for an extremely high economic burden on the sheller.
- 1 January 2012
- Published by American Peanut Research and Education Society in Peanut Science
- Vol. 39 (1) , 69-81
Comparing the USDA/AMS Subsampling Mill to a Vertical Cutter Mixer Type Mill Used to Comminute Shelled Peanut Samples for Aflatoxin Analysis1
The US peanut industry can use up to three 21.8 kg samples per lot to determine if shelled peanut lots are acceptable or unacceptable due to aflatoxin content. If a lot is accepted by the first 21.8 kg sample (1AB≤8 ng/g) prepared with the USDA/AMS Subsampling mill (DM), then some peanut buyers request that the sheller prepare the second sample (2AB) and in some cases the 3AB sample (called special samples in the trade) with a vertical cutter mixer (VCM) type mill. These requests to specifically use the VCM instead of the DM to prepare official (1AB) and special (2AB or 3AB) samples is based in part on a perception that analytical results associated with a test portion taken from the 21.8 kg sample comminuted with a DM does not detect the full magnitude of aflatoxin in the 21.8 kg sample and that negative aflatoxin certificates (lot acceptance) are more likely to occur when samples are prepared with a DM than a VCM. Analysis of aflatoxin test results from two shellers along with Monte Carlo simulation indicate that differences between the 1AB and special sample test results are due to the use of a cut-off limit (≤ 8 ng/g associated with the 1AB) requested by the buyer as part of the acceptance criteria and not due to any bias associated with the DM. Operating characteristic curves were used to demonstrate that the performance of the USDA/AMS aflatoxin sampling plan is about the same regardless of the use of a DM or a VCM for sample preparation. The performances are similar because the DM, with an 1100 g test portion, account for only 8% of the total variability of the aflatoxin test procedure (sampling and analysis account for about 92%). A sampling plan that requires two 21.8 kg samples to test less than a limit, regardless of mill used to prepare the two samples, has a very low risk of accepting bad lots above the FDA limit of 20 ng/g, but has a very high risk of rejecting good lots, which makes for an extremely high economic burden on the sheller.
- Open Access
- 1 July 2007
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 90 (4) , 1060-1072
Evaluating the Performance of Sampling Plans to Detect Hypoglycin A in Ackee Fruit Shipments Imported into the United States
Hypoglycin A (HGA) is a toxic amino acid that is naturally produced in unripe ackee fruit. In 1973, the U.S. Food and Drug Administration (FDA) placed a worldwide import alert on ackee fruit, which banned the product from entering the United States. The FDA has considered establishing a regulatory limit for HGA and lifting the ban, which will require development of a monitoring program. The establishment of a regulatory limit for HGA requires the development of a scientifically based sampling plan to detect HGA in ackee fruit imported into the United States. Thirty-three lots of ackee fruit were sampled according to an experimental protocol in which 10 samples, i.e., ten 19 oz cans, were randomly taken from each lot and analyzed for HGA by using liquid chromatography. The total variance was partitioned into sampling and analytical variance components, which were found to be a function of the HGA concentration. Regression equations were developed to predict the total, sampling, and analytical variances as a function of HGA concentration. The observed HGA distribution among the test results for the 10 HGA samples was compared with the normal and lognormal distributions. A computer model based on the lognormal distribution was developed to predict the performance of sampling plan designs to detect HGA in ackee fruit shipments. The performance of several sampling plan designs was evaluated to demonstrate how to manipulate sample size and accept/reject limits to reduce misclassification of ackee fruit lots.
- 1 July 2007
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 90 (4) , 1060-1072
Open AccessEvaluating the Performance of Sampling Plans to Detect Hypoglycin A in Ackee Fruit Shipments Imported into the United States
Hypoglycin A (HGA) is a toxic amino acid that is naturally produced in unripe ackee fruit. In 1973, the U.S. Food and Drug Administration (FDA) placed a worldwide import alert on ackee fruit, which banned the product from entering the United States. The FDA has considered establishing a regulatory limit for HGA and lifting the ban, which will require development of a monitoring program. The establishment of a regulatory limit for HGA requires the development of a scientifically based sampling plan to detect HGA in ackee fruit imported into the United States. Thirty-three lots of ackee fruit were sampled according to an experimental protocol in which 10 samples, i.e., ten 19 oz cans, were randomly taken from each lot and analyzed for HGA by using liquid chromatography. The total variance was partitioned into sampling and analytical variance components, which were found to be a function of the HGA concentration. Regression equations were developed to predict the total, sampling, and analytical variances as a function of HGA concentration. The observed HGA distribution among the test results for the 10 HGA samples was compared with the normal and lognormal distributions. A computer model based on the lognormal distribution was developed to predict the performance of sampling plan designs to detect HGA in ackee fruit shipments. The performance of several sampling plan designs was evaluated to demonstrate how to manipulate sample size and accept/reject limits to reduce misclassification of ackee fruit lots.
- 22 June 2007
- Vol. 90 (3) , 778-85
Sampling almonds for aflatoxin, part II: estimating risks associated with various sampling plan designs.
About 100 nations have established regulatory limits for aflatoxin in food and feeds. Because these limits vary widely from one country to another, the Codex Alimentarius Commission, working through the Codex Committee on Food Additives and Contaminants, has initiated work to harmonize aflatoxin limits and sampling plans for almonds, pistachios, hazelnuts, and Brazil nuts. Studies were developed to measure the uncertainty and distribution among test results for replicate samples taken from aflatoxin-contaminated almond shipments. The uncertainty and distribution information was used to develop a model to evaluate the performance of aflatoxin sampling plans so that harmonized sampling plans can be developed for almonds that reduce the misclassifying of lots in the export trade. Twenty lots of shelled almonds were sampled according to an experimental protocol in which sixteen 10 kg samples were taken from each lot. The observed aflatoxin distribution among the 16 sample test results was compared with 3 theoretical distributions. The negative binomial distribution was selected to model aflatoxin distribution among sample test results because it gave acceptable fits across all 20 observed sample distributions. By using the variance and distribution information, operating characteristics curves were developed to predict the effect of sample size and accept/reject limits on the probability of rejecting good lots and accepting bad lots.
- 22 June 2007
- Vol. 90 (3) , 778-85
Sampling almonds for aflatoxin, part II: estimating risks associated with various sampling plan designs.
About 100 nations have established regulatory limits for aflatoxin in food and feeds. Because these limits vary widely from one country to another, the Codex Alimentarius Commission, working through the Codex Committee on Food Additives and Contaminants, has initiated work to harmonize aflatoxin limits and sampling plans for almonds, pistachios, hazelnuts, and Brazil nuts. Studies were developed to measure the uncertainty and distribution among test results for replicate samples taken from aflatoxin-contaminated almond shipments. The uncertainty and distribution information was used to develop a model to evaluate the performance of aflatoxin sampling plans so that harmonized sampling plans can be developed for almonds that reduce the misclassifying of lots in the export trade. Twenty lots of shelled almonds were sampled according to an experimental protocol in which sixteen 10 kg samples were taken from each lot. The observed aflatoxin distribution among the 16 sample test results was compared with 3 theoretical distributions. The negative binomial distribution was selected to model aflatoxin distribution among sample test results because it gave acceptable fits across all 20 observed sample distributions. By using the variance and distribution information, operating characteristics curves were developed to predict the effect of sample size and accept/reject limits on the probability of rejecting good lots and accepting bad lots.
- Open Access
- 1 July 2006
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 89 (4) , 1021-1026
Testing Green Coffee for Ochratoxin A, Part III: Performance of Ochratoxin A Sampling Plan
Green coffee shipments are often inspected for ochratoxin A (OTA) and classified into good or bad categories depending on whether the OTA estimates are above or below a defined regulatory limit. Because of the uncertainty associated with the sampling, sample preparation, and analytical steps of an OTA test procedure, some shipments of green coffee will be misclassified. The misclassification of lots leads to some good lots being rejected (sellers' risk) and some bad lots being accepted (buyers' risk) by an OTA sampling plan. Reducing the uncertainty of an OTA test procedure and using an accept/reject limit less than the regulatory limit can reduce the magnitude of one or both risks. The uncertainty of the OTA test procedure is most effectively reduced by increasing sample size (or increasing the number of samples analyzed), because the sampling step is the largest source of uncertainty in the OTA test procedure. The effects of increasing sample size and changing the sample accept/reject limit relative to the regulatory limit on the performance of OTA sampling plans for green coffee were investigated. For a given accept/reject limit of 5 μg/kg, increasing sample size increased the percentage of lots accepted at concentrations below the regulatory limit and increased the percentage of lots rejected at concentrations above the regulatory limit. As a result, increasing sample size reduced both the number of good lots rejected (sellers' risk) and the number of bad lots accepted (buyers' risk). For a given sample size (1 kg), decreasing the sample accept/reject limit from 5 to 2 μg/kg relative to a fixed regulatory limit of 5 μg/kg decreased the percentage of lots accepted and increased the percentage of lots rejected at all OTA concentrations. As a result, decreasing the accept/reject limit below the regulatory limit increased the number of good lots rejected (sellers' risk), but decreased the number of bad lots accepted (buyers' risk).
- 1 July 2006
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 89 (4) , 1021-1026
Open AccessTesting Green Coffee for Ochratoxin A, Part III: Performance of Ochratoxin A Sampling Plan
Green coffee shipments are often inspected for ochratoxin A (OTA) and classified into good or bad categories depending on whether the OTA estimates are above or below a defined regulatory limit. Because of the uncertainty associated with the sampling, sample preparation, and analytical steps of an OTA test procedure, some shipments of green coffee will be misclassified. The misclassification of lots leads to some good lots being rejected (sellers' risk) and some bad lots being accepted (buyers' risk) by an OTA sampling plan. Reducing the uncertainty of an OTA test procedure and using an accept/reject limit less than the regulatory limit can reduce the magnitude of one or both risks. The uncertainty of the OTA test procedure is most effectively reduced by increasing sample size (or increasing the number of samples analyzed), because the sampling step is the largest source of uncertainty in the OTA test procedure. The effects of increasing sample size and changing the sample accept/reject limit relative to the regulatory limit on the performance of OTA sampling plans for green coffee were investigated. For a given accept/reject limit of 5 μg/kg, increasing sample size increased the percentage of lots accepted at concentrations below the regulatory limit and increased the percentage of lots rejected at concentrations above the regulatory limit. As a result, increasing sample size reduced both the number of good lots rejected (sellers' risk) and the number of bad lots accepted (buyers' risk). For a given sample size (1 kg), decreasing the sample accept/reject limit from 5 to 2 μg/kg relative to a fixed regulatory limit of 5 μg/kg decreased the percentage of lots accepted and increased the percentage of lots rejected at all OTA concentrations. As a result, decreasing the accept/reject limit below the regulatory limit increased the number of good lots rejected (sellers' risk), but decreased the number of bad lots accepted (buyers' risk).
- Open Access
- 1 July 2006
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 89 (4) , 1027-1034
Sampling Almonds for Aflatoxin, Part I: Estimation of Uncertainty Associated with Sampling, Sample Preparation, and Analysis
Domestic and international regulatory limits have been established for aflatoxin in almonds and other tree nuts. It is difficult to obtain an accurate and precise estimate of the true aflatoxin concentration in a bulk lot because of the uncertainty associated with the sampling, sample preparation, and analytical steps of the aflatoxin test procedure. To evaluate the performance of aflatoxin sampling plans, the uncertainty associated with sampling lots of shelled almonds for aflatoxin was investigated. Twenty lots of shelled almonds were sampled for aflatoxin contamination. The total variance associated with measuring B1 and total aflatoxins in bulk almond lots was estimated and partitioned into sampling, sample preparation, and analytical variance components. All variances were found to increase with an increase in aflatoxin concentration (both B1 and total). By using regression analysis, mathematical expressions were developed to predict the relationship between each variance component (total, sampling, sample preparation, and analysis variances) and aflatoxin concentration. Variance estimates were the same for B1 and total aflatoxins. The mathematical relationships can be used to estimate each variance for a given sample size, subsample size, and number of analyses other than that measured in the study. When a lot with total aflatoxins at 15 ng/g was tested by using a 10 kg sample, a vertical cutter mixer type of mill, a 100 g subsample, and high-performance liquid chromatography analysis, the sampling, sample preparation, analytical, and total variances (coefficient of variation, CV) were 394.7 (CV, 132.4%), 14.7 (CV, 25.5%), 0.8 (CV, 6.1%), and 410.2 (CV, 135.0%), respectively. The percentages of the total variance associated with sampling, sample preparation, and analytical steps were 96.2, 3.6, and 0.2, respectively.
- 1 July 2006
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 89 (4) , 1027-1034
Open AccessSampling Almonds for Aflatoxin, Part I: Estimation of Uncertainty Associated with Sampling, Sample Preparation, and Analysis
Domestic and international regulatory limits have been established for aflatoxin in almonds and other tree nuts. It is difficult to obtain an accurate and precise estimate of the true aflatoxin concentration in a bulk lot because of the uncertainty associated with the sampling, sample preparation, and analytical steps of the aflatoxin test procedure. To evaluate the performance of aflatoxin sampling plans, the uncertainty associated with sampling lots of shelled almonds for aflatoxin was investigated. Twenty lots of shelled almonds were sampled for aflatoxin contamination. The total variance associated with measuring B1 and total aflatoxins in bulk almond lots was estimated and partitioned into sampling, sample preparation, and analytical variance components. All variances were found to increase with an increase in aflatoxin concentration (both B1 and total). By using regression analysis, mathematical expressions were developed to predict the relationship between each variance component (total, sampling, sample preparation, and analysis variances) and aflatoxin concentration. Variance estimates were the same for B1 and total aflatoxins. The mathematical relationships can be used to estimate each variance for a given sample size, subsample size, and number of analyses other than that measured in the study. When a lot with total aflatoxins at 15 ng/g was tested by using a 10 kg sample, a vertical cutter mixer type of mill, a 100 g subsample, and high-performance liquid chromatography analysis, the sampling, sample preparation, analytical, and total variances (coefficient of variation, CV) were 394.7 (CV, 132.4%), 14.7 (CV, 25.5%), 0.8 (CV, 6.1%), and 410.2 (CV, 135.0%), respectively. The percentages of the total variance associated with sampling, sample preparation, and analytical steps were 96.2, 3.6, and 0.2, respectively.
- Open Access
- 1 September 2004
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 87 (4) , 950-960
Evaluation of Sampling Plans to Detect Cry9C Protein in Corn Flour and Meal
StarLink is a genetically modified corn that produces an insecticidal protein, Cry9C. Studies were conducted to determine the variability and Cry9C distribution among sample test results when Cry9C protein was estimated in a bulk lot of corn flour and meal. Emphasis was placed on measuring sampling and analytical variances associated with each step of the test procedure used to measure Cry9C in corn flour and meal. Two commercially available enzyme-linked immunosorbent assay kits were used: one for the determination of Cry9C protein concentration and the other for % StarLink seed. The sampling and analytical variances associated with each step of the Cry9C test procedures were determined for flour and meal. Variances were found to be functions of Cry9C concentration, and regression equations were developed to describe the relationships. Because of the larger particle size, sampling variability associated with cornmeal was about double that for corn flour. For cornmeal, the sampling variance accounted for 92.6% of the total testing variability. The observed sampling and analytical distributions were compared with the Normal distribution. In almost all comparisons, the null hypothesis that the Cry9C protein values were sampled from a Normal distribution could not be rejected at 95% confidence limits. The Normal distribution and the variance estimates were used to evaluate the performance of several Cry9C protein sampling plans for corn flour and meal. Operating characteristic curves were developed and used to demonstrate the effect of increasing sample size on reducing false positives (seller's risk) and false negatives (buyer's risk).
- 1 September 2004
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 87 (4) , 950-960
Open AccessEvaluation of Sampling Plans to Detect Cry9C Protein in Corn Flour and Meal
StarLink is a genetically modified corn that produces an insecticidal protein, Cry9C. Studies were conducted to determine the variability and Cry9C distribution among sample test results when Cry9C protein was estimated in a bulk lot of corn flour and meal. Emphasis was placed on measuring sampling and analytical variances associated with each step of the test procedure used to measure Cry9C in corn flour and meal. Two commercially available enzyme-linked immunosorbent assay kits were used: one for the determination of Cry9C protein concentration and the other for % StarLink seed. The sampling and analytical variances associated with each step of the Cry9C test procedures were determined for flour and meal. Variances were found to be functions of Cry9C concentration, and regression equations were developed to describe the relationships. Because of the larger particle size, sampling variability associated with cornmeal was about double that for corn flour. For cornmeal, the sampling variance accounted for 92.6% of the total testing variability. The observed sampling and analytical distributions were compared with the Normal distribution. In almost all comparisons, the null hypothesis that the Cry9C protein values were sampled from a Normal distribution could not be rejected at 95% confidence limits. The Normal distribution and the variance estimates were used to evaluate the performance of several Cry9C protein sampling plans for corn flour and meal. Operating characteristic curves were developed and used to demonstrate the effect of increasing sample size on reducing false positives (seller's risk) and false negatives (buyer's risk).
- Open Access
- 1 July 2004
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 87 (4) , 884-891
Testing Green Coffee for Ochratoxin A, Part I: Estimation of Variance Components
The variability associated with testing lots of green coffee beans for ochratoxin A (OTA) was investigated. Twenty-five lots of green coffee were tested for OTA contamination. The total variance associated with testing green coffee was estimated and partitioned into sampling, sample preparation, and analytical variances. All variances increased with an increase in OTA concentration. Using regression analysis, mathematical expressions were developed to model the relationship between OTA concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific OTA concentration. Testing a lot with 5 μg/kg OTA using a 1 kg sample, Romer RAS mill, 25 g subsamples, and liquid chromatography analysis, the total, sampling, sample preparation, and analytical variances were 10.75 (coefficient of variation [CV] = 65.6%), 7.80 (CV = 55.8%), 2.84 (CV = 33.7%), and 0.11 (CV = 6.6%), respectively. The total variance for sampling, sample preparation, and analytical were 73, 26, and 1%, respectively.
- 1 July 2004
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 87 (4) , 884-891
Open AccessTesting Green Coffee for Ochratoxin A, Part I: Estimation of Variance Components
The variability associated with testing lots of green coffee beans for ochratoxin A (OTA) was investigated. Twenty-five lots of green coffee were tested for OTA contamination. The total variance associated with testing green coffee was estimated and partitioned into sampling, sample preparation, and analytical variances. All variances increased with an increase in OTA concentration. Using regression analysis, mathematical expressions were developed to model the relationship between OTA concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific OTA concentration. Testing a lot with 5 μg/kg OTA using a 1 kg sample, Romer RAS mill, 25 g subsamples, and liquid chromatography analysis, the total, sampling, sample preparation, and analytical variances were 10.75 (coefficient of variation [CV] = 65.6%), 7.80 (CV = 55.8%), 2.84 (CV = 33.7%), and 0.11 (CV = 6.6%), respectively. The total variance for sampling, sample preparation, and analytical were 73, 26, and 1%, respectively.
- Open Access
- 1 July 2004
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 87 (4) , 943-949
Variation of Analytical Results for Peanuts in Energy Bars and Milk Chocolate
Peanuts contain proteins that can cause severe allergic reactions in some sensitized individuals. Studies were conducted to determine the percentage of recovery by an enzyme-linked immunosorbent assay (ELISA) method in the analysis for peanuts in energy bars and milk chocolate and to determine the sampling, subsampling, and analytical variances associated with testing energy bars and milk chocolate for peanuts. Food products containing chocolate were selected because their composition makes sample preparation for subsampling difficult. Peanut-contaminated energy bars, noncontaminated energy bars, incurred milk chocolate containing known levels of peanuts, and peanut-free milk chocolate were used. A commercially available ELISA kit was used for analysis. The sampling, sample preparation, and analytical variances associated with each step of the test procedure to measure peanut protein were determined for energy bars. The sample preparation and analytical variances were determined for milk chocolate. Variances were found to be functions of peanut concentration. Sampling and subsampling variability associated with energy bars accounted for 96.6% of the total testing variability. Subsampling variability associated with powdered milk chocolate accounted for >60% of the total testing variability. The variability among peanut test results can be reduced by increasing sample size, subsample size, and number of analyses. For energy bars the effect of increasing sample size from 1 to 4 bars, subsample size from 5 to 20 g, and number of aliquots quantified from 1 to 2 on reducing the sampling, sample preparation, and analytical variance was demonstrated. For powdered milk chocolate, the effects of increasing subsample size from 5 to 20 g and number of aliquots quantified from 1 to 2 on reducing sample preparation and analytical variances were demonstrated. This study serves as a template for application to other foods, and for extrapolation to different sizes of samples and subsamples as well as numbers of analyses.
- 1 July 2004
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 87 (4) , 943-949
Open AccessVariation of Analytical Results for Peanuts in Energy Bars and Milk Chocolate
Peanuts contain proteins that can cause severe allergic reactions in some sensitized individuals. Studies were conducted to determine the percentage of recovery by an enzyme-linked immunosorbent assay (ELISA) method in the analysis for peanuts in energy bars and milk chocolate and to determine the sampling, subsampling, and analytical variances associated with testing energy bars and milk chocolate for peanuts. Food products containing chocolate were selected because their composition makes sample preparation for subsampling difficult. Peanut-contaminated energy bars, noncontaminated energy bars, incurred milk chocolate containing known levels of peanuts, and peanut-free milk chocolate were used. A commercially available ELISA kit was used for analysis. The sampling, sample preparation, and analytical variances associated with each step of the test procedure to measure peanut protein were determined for energy bars. The sample preparation and analytical variances were determined for milk chocolate. Variances were found to be functions of peanut concentration. Sampling and subsampling variability associated with energy bars accounted for 96.6% of the total testing variability. Subsampling variability associated with powdered milk chocolate accounted for >60% of the total testing variability. The variability among peanut test results can be reduced by increasing sample size, subsample size, and number of analyses. For energy bars the effect of increasing sample size from 1 to 4 bars, subsample size from 5 to 20 g, and number of aliquots quantified from 1 to 2 on reducing the sampling, sample preparation, and analytical variance was demonstrated. For powdered milk chocolate, the effects of increasing subsample size from 5 to 20 g and number of aliquots quantified from 1 to 2 on reducing sample preparation and analytical variances were demonstrated. This study serves as a template for application to other foods, and for extrapolation to different sizes of samples and subsamples as well as numbers of analyses.
- Open Access
- 1 November 2003
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 86 (6) , 1187-1192
Estimating Deoxynivalenol in Shelled Corn Barge Lots by Measuring Deoxynivalenol in Corn Screenings
To determine if deoxynivalenol (DON) is concentrated in small corn screenings, fourteen to twenty-three 1.1 kg test samples were taken from each of 10 barges of shelled corn. Each of the 181 test samples was divided into 2 components (fines and clean) using a 5 mm screen. The clean component sample rode the 5 mm screen and the fines component sample passed through the 5 mm screen. The DON concentration in fines component sample was about 3 times the DON concentration in the clean component sample. The DON in the 181 fines and clean component samples averaged 689.0 and 206.1 ng/g, respectively. Regression equations were developed to predict the DON in the barge based upon measurements of DON in the fines component sample. The ratio of DON in the lot to DON in the fines component sample was 0.359. The coefficient of variation (CV) associated with predicting the DON concentration in a lot with 359 ng/g using a 1.1 kg test sample was 47.0%. Increasing sample size to 4.4 kg reduced the CV to 23%.
- 1 November 2003
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 86 (6) , 1187-1192
Open AccessEstimating Deoxynivalenol in Shelled Corn Barge Lots by Measuring Deoxynivalenol in Corn Screenings
To determine if deoxynivalenol (DON) is concentrated in small corn screenings, fourteen to twenty-three 1.1 kg test samples were taken from each of 10 barges of shelled corn. Each of the 181 test samples was divided into 2 components (fines and clean) using a 5 mm screen. The clean component sample rode the 5 mm screen and the fines component sample passed through the 5 mm screen. The DON concentration in fines component sample was about 3 times the DON concentration in the clean component sample. The DON in the 181 fines and clean component samples averaged 689.0 and 206.1 ng/g, respectively. Regression equations were developed to predict the DON in the barge based upon measurements of DON in the fines component sample. The ratio of DON in the lot to DON in the fines component sample was 0.359. The coefficient of variation (CV) associated with predicting the DON concentration in a lot with 359 ng/g using a 1.1 kg test sample was 47.0%. Increasing sample size to 4.4 kg reduced the CV to 23%.