Dietmar-Pierree König
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dietmar-Pierree König has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Christoph Bertram
Department of Orthopaedic Surgery, Cologne University, Joseph Stelzmann Strasse 9, 50924 Köln, Germany
1 shared publicationFrancoise Perdreau-Remington
University of California San Francisco, San Francisco, CA, USA
1 shared publication- Frank Popken
Department of Orthopaedic Surgery, University of Cologne, Josef-Stelzmann-Str, 9, 50931 Cologne, Germany
1 shared publication - Heike Erberich
Institute of Pathology, University of Cologne, Josef-Stelzmann-Str. 9, 50931 Cologne, Germany
1 shared publication Jörg Schierholz
Center of Advanced European Studies and Research, Bonn, Germany
1 shared publicationJürgen Rütt
Department of Orthopaedic Surgery, Cologne University, Joseph Stelzmann Strasse 9, 50924 Köln, Germany
1 shared publication
Latest Publications
- 7 August 2003
- Vol. 140 (6) , 581
[Secondary arthropathy after arthrodesis of the lower ankle joint].
- Open Access
- 22 April 2003
- Published by Springer Nature in BMC Surgery
- Vol. 3 (1) , 3
The use of a new miniature cryoprobe for ablation of bone tissue: In vivo assessment of the probe and application of the method to bone in a sheep model
So far, modern miniature cryoprobes were used for local destruction of soft tissue tumours without damaging the adjacent healthy tissue. In this study, cryoablation methodology was applied to bone and the cooling capacity of the probe was examined in vitro and in vivo. Freezing was performed by cooling one or two probes (diameter 3.2 mm) to -180°C with liquid nitrogen. The cooling capacity of the probes was determined optically and thermally against a homogeneous reference gel, followed by in vivo measurements on femoral and tibial sheep bone followed by histological examination. Thanks to the synergistic effect, the simultaneous use of 2 probes produced an almost spherical expansion of cold in the homogenous gelatin. During the in vivo freezes, the temperature curves showed a more moderate trend. Nevertheless, due to the synergistic effect, temperatures below -50°C could be reached at a distance of 1 cm from the probe. No local or systemic intraoperative complications were observed. Histological examination revealed cell necrosis up into the -10°C isotherm. Adequate tissue cooling of the bone matrix can be achieved with in vivo freezes by means of one or more miniature cryoprobes. Therefore, this probe could provide an alternative to or supplement surgical resection of pathological bone processes.
- 22 April 2003
- Published by Springer Nature in BMC Surgery
- Vol. 3 (1) , 3
Open AccessThe use of a new miniature cryoprobe for ablation of bone tissue: In vivo assessment of the probe and application of the method to bone in a sheep model
So far, modern miniature cryoprobes were used for local destruction of soft tissue tumours without damaging the adjacent healthy tissue. In this study, cryoablation methodology was applied to bone and the cooling capacity of the probe was examined in vitro and in vivo. Freezing was performed by cooling one or two probes (diameter 3.2 mm) to -180°C with liquid nitrogen. The cooling capacity of the probes was determined optically and thermally against a homogeneous reference gel, followed by in vivo measurements on femoral and tibial sheep bone followed by histological examination. Thanks to the synergistic effect, the simultaneous use of 2 probes produced an almost spherical expansion of cold in the homogenous gelatin. During the in vivo freezes, the temperature curves showed a more moderate trend. Nevertheless, due to the synergistic effect, temperatures below -50°C could be reached at a distance of 1 cm from the probe. No local or systemic intraoperative complications were observed. Histological examination revealed cell necrosis up into the -10°C isotherm. Adequate tissue cooling of the bone matrix can be achieved with in vivo freezes by means of one or more miniature cryoprobes. Therefore, this probe could provide an alternative to or supplement surgical resection of pathological bone processes.
- 1 August 2001
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 386 (5) , 328-332
In vitro adherence and accumulation of Staphylococcus epidermidis RP 62 A and Staphylococcus epidermidis M7 on four different bone cements
Bacterial resistance of Staphylococcus epidermidis, a serious pathogen of implant-related infections, to antibiotics is related to the production of a glycocalyx slime that impairs antibiotic access and the killing by host defense mechanisms. In vitro studies of different bone cements containing antibiotics, developed for the prevention of biomaterial-associated infection, could not always demonstrate complete eradication of biomaterial-adherent bacteria. We have investigated four different bone cements in regard to bacterial accumulation of a slime-producing strain RP 62 A and its isogenic mutant M7 lacking the ability to produce exopolysaccharide slime using a bacterial adhesion assay and modified Kirby-Bauer technique. A significant effect of exopolysaccharide production for the accumulation on bone cement could be demonstrated. The gentamicin/clindamycin bone cement was the only tested biomaterial that produced a large zone of bacterial inhibition in the inoculated area adjacent to the biomaterial. The bacterial adhesion was not reduced significantly and there was no correlation between zones of inhibition on blood agar plates and the quantitative adhesion assay. The clinical efficacy of the gentamicin/clindamycin bone cement must be proven in vivo.
- 1 August 2001
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 386 (5) , 328-332
In vitro adherence and accumulation of Staphylococcus epidermidis RP 62 A and Staphylococcus epidermidis M7 on four different bone cements
Bacterial resistance of Staphylococcus epidermidis, a serious pathogen of implant-related infections, to antibiotics is related to the production of a glycocalyx slime that impairs antibiotic access and the killing by host defense mechanisms. In vitro studies of different bone cements containing antibiotics, developed for the prevention of biomaterial-associated infection, could not always demonstrate complete eradication of biomaterial-adherent bacteria. We have investigated four different bone cements in regard to bacterial accumulation of a slime-producing strain RP 62 A and its isogenic mutant M7 lacking the ability to produce exopolysaccharide slime using a bacterial adhesion assay and modified Kirby-Bauer technique. A significant effect of exopolysaccharide production for the accumulation on bone cement could be demonstrated. The gentamicin/clindamycin bone cement was the only tested biomaterial that produced a large zone of bacterial inhibition in the inoculated area adjacent to the biomaterial. The bacterial adhesion was not reduced significantly and there was no correlation between zones of inhibition on blood agar plates and the quantitative adhesion assay. The clinical efficacy of the gentamicin/clindamycin bone cement must be proven in vivo.